Ignition Coil Resistance Check
- Turn ignition switch off. Remove coil wires. Using an ohmmeter set at the low scale, attach leads to ignition coil primary terminals 1 and 15 (wires removed). See Fig 1. Take primary resistance reading.
- Set ohmmeter to x1000 scale. Connect ohmmeter leads to negative terminal 1 and coil tower terminal 4 (high tension). Take secondary resistance reading.
- If either the primary or the secondary reading was not within specifications, replace coil.
IGNITION COIL RESISTANCE SPECIFICATION
| Application | Primary | Secondary |
|---|---|---|
| 760 GLE | 0.5-1.0 | 7500-12,000 |
| All Others | 1.0-2.0 | N/A |