Preparation For Checks
- Frequency valve is operated by pulsating voltage from ECU. By measuring this signal, mixture function of system can be tested and changed. High-quality dwell meter may be used on all other models.
- Connect dwell meter to 2-wire testing connector. Connector on Volvo is on left side shock tower just behind battery (Pink wire).
- The color-coded wire should be connected to positive (+) lead of dwell meter. Other wire in connector is ground and should be connected to negative (-) lead of dwell meter. Set dwell meter on 4-cylinder scale. Start engine and run until warm.