If No Click Is Heard
Interchanged connector w/one that operates properly. If fault is trasferred to the "known-good" injector, this shows that the fault lies w/wiring. If original injector still does not function, it is probably defective. Mearsure injector resistance. Resistance should be 16 ohms at 20°C (68°F). Resistance increases as temperature rises.