Checking Ground Connections

  1. Turn ignition off. Remove fuse No. 24. Connect Measuring Unit (999-3070 ) to ECU. See Fig 1 . Connect ohmmeter between ground and terminals No. 19, 24, 26, 30 and 48. Resistance should be about zero ohms on all measurements.
  2. Check power unit ground connections under each power unit. Connect an ohmmeter between ground and terminal No. 4 on front power unit connector and then on rear power unit connector.
  3. Ohmmeter should indicate about zero ohms in both cases. If ohmmeter does not indicate about zero ohms in both cases, check connectors and wiring.
Fig 1: Connecting Measuring Unit (999-3070) To ECU
G92I26110Courtesy of VOLVO CARS OF NORTH AMERICA.