Checking for an open-circuit in the cable
Check cable between control module #23 and ignition switch terminal 15I for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification
Check cable between control module #9 and battery for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification
Check cable between data link connector (DLC) terminal 7 and transmission control module (TCM) #13 for an open-circuit according to Open-circuit, permanent faults .
Select "Continue" when the fault has been repaired.
- Continue
Refer to Verification