Starter No-Load Test
With starter on bench, operate starter and check ammeter, voltage and RPM. Readings should be within specification. See appropriate STARTER NO-LOAD TEST SPECIFICATIONS table.
STARTER NO-LOAD TEST SPECIFICATIONS (C70, S70 & V70)
| Application | Volts | Amps | RPM |
|---|---|---|---|
| 0 001 108 153 | 11.5 | 75 | 2900 |
| 0 001 108 166/167 | 12.0 | 75 | 3000 |
| 0 001 110 063 | 11.2 | 95 | 2800 |
| 0 001 111 142 | 11.5 | 75 | 2900 |
| 0 001 233 618 | 12.0 | 70 | 6100 |
STARTER NO-LOAD TEST SPECIFICATIONS (S90 & V90)
| Application | Volts | Amps | RPM |
|---|---|---|---|
| 0 001 108 088/089/090 | 11.5 | 75 | 2900 |
| 0 001 110 063/068 | 11.2 | 95 | 2800 |
| 0 001 115 002 | 11.6 | 100 | 3140 |
| 0 001 218 017 | 11.6 | 100 | 3140 |
| 0 001 218 130 | 10.5 | 160 | 4200 |