Circuit Check General Information (S80)
Power supply to the ECM terminal A70 is from fuse 11 B/18 via the system relay. See appropriate WIRING DIAGRAMS article. Power supply to ECM terminals B11 is from fuse 11 B/14 via relay terminal 30+. The ECM ground terminal is common to ECM terminals A53, A54 and A63 (turbo models).