Outside Temperature Sensor
Disconnect outside temperature sensor connector. Using an ohmmeter, measure resistance between sensor terminals. See OUTSIDE TEMPERATURE SENSOR SPECIFICATIONS (ME7) table. If resistance is not as specified, replace sensor.
OUTSIDE TEMPERATURE SENSOR SPECIFICATIONS (ME7)
| Temperature - °F (°C) | Voltage | Resistance - Ohms |
|---|---|---|
| 0 (0) | 2.92 | 1407 |
| 50 (10) | 2.39 | 912.8 |
| 68 (20) | 1.89 | 607.5 |
| 77 (25) | 1.67 | 500 |
| 86 (30) | 1.46 | 413.8 |
OUTSIDE TEMPERATURE SENSOR SPECIFICATIONS (DENSO)
| Temperature - °F (°C) | Voltage | Resistance - Ohms |
|---|---|---|
| 32 (0) | 2.34 | 1407 |
| 50 (10) | 1.82 | 912.8 |
| 68 (20) | 1.38 | 607.5 |
| 77 (25) | 1.19 | 500 |
| 86 (30) | 1.03 | 413.8 |