Passenger Door Module (PDM) DTCS
PASSENGER DOOR MODULE (PDM) - DTC INDEX
| DTC | Description |
|---|---|
| PDM-B108F23 | Cabin Lock/Unlock Switch. General Signal Failures. Signal stuck low |
| PDM-B10EC11 | Passenger door double locking motor. General Electrical Failures. Circuit short to ground |
| PDM-B10EC15 | Passenger door double locking motor. General Electrical Failures. Circuit short to battery or open |
| PDM-B10EE11 | Rear door passenger side double locking motor. General Electrical Failures. Circuit short to ground |
| PDM-B10EE15 | Rear door passenger side double locking motor. General Electrical Failures. Circuit short to battery or open |
| PDM-B110911 | Passenger door central locking motor. General Electrical Failures. Circuit short to ground |
| PDM-B110915 | Passenger door central locking motor. General Electrical Failures. Circuit short to battery or open |
| PDM-B110B11 | Rear door passenger side central locking motor. General Electrical Failures. Circuit short to ground |
| PDM-B110B15 | Rear door passenger side central locking motor. General Electrical Failures. Circuit short to battery or open |
| PDM-B110D11 | Rear door passenger side power child locking motor. General Electrical Failures. Circuit short to ground |
| PDM-B110D15 | Rear door passenger side power child locking motor. General Electrical Failures. Circuit short to battery or open |
| PDM-B116311 | Left mirror heater output. General Electrical Failures. Circuit short to ground |
| PDM-B116315 | Left mirror heater output. General Electrical Failures. Circuit short to battery or open |
| PDM-B116411 | Right mirror heater output. General Electrical Failures. Circuit short to ground |
| PDM-B116415 | Right mirror heater output. General Electrical Failures. Circuit short to battery or open |
| PDM-B116511 | Left front puddle lamp output. General Electrical Failures. Circuit short to ground |
| PDM-B116515 | Left front puddle lamp output. General Electrical Failures. Circuit short to battery or open |
| PDM-B116611 | Right front puddle lamp output. General Electrical Failures. Circuit short to ground |
| PDM-B116615 | Left front puddle lamp output. General Electrical Failures. Circuit short to battery or open |
| PDM-B117C07 | Rear power window up. General Failure Information. Mechanical Failures |
| PDM-B117C72 | Rear power window up. Mechanical Failures. Actuator stuck open |
| PDM-B117C73 | Rear power window up. Mechanical Failures. Actuator stuck closed |
| PDM-B117D72 | Rear power window down. Mechanical Failures. Actuator stuck open |
| PDM-B117D73 | Rear power window down. Mechanical Failures. Actuator stuck closed |
| PDM-B117E07 | Front power window up. General Failure Information. Mechanical Failures |
| PDM-B117E72 | Front power window up. Mechanical Failures. Actuator stuck open |
| PDM-B117E73 | Front power window up. Mechanical Failures. Actuator stuck closed |
| PDM-B117F72 | Front power window down. Mechanical Failures. Actuator stuck open |
| PDM-B117F73 | Front power window down. Mechanical Failures. Actuator stuck closed |
| PDM-B118929 | Front Window Position Sensor. General Signal Failures. Signal signal invalid |
| PDM-B118A29 | Rear Window Position Sensor. General Signal Failures. Signal signal invalid |
| PDM-B118C04 | Left blind spot warning indicator. General Failure Information. System Internal Failures |
| PDM-B118C11 | Left blind spot warning indicator. General Electrical Failures. Circuit short to ground |
| PDM-B118C12 | Left blind spot warning indicator. General Electrical Failures. Circuit short to battery |
| PDM-B118C13 | Left blind spot warning indicator. General Electrical Failures. Circuit open |
| PDM-B118D04 | Invalid data received from "Door Control Module A". General Failure Information. System Internal Failures |
| PDM-B118D11 | Right blind spot warning indicator. General Electrical Failures. Circuit short to ground |
| PDM-B118D12 | Right blind spot warning indicator. General Electrical Failures. Circuit short to battery |
| PDM-B118D13 | Right blind spot warning indicator. General Electrical Failures. Circuit open |
| PDM-B11B911 | Passenger Blind Spot Warning Indicator Supply. General Electrical Failures. Circuit short to ground |
| PDM-B11B915 | Passenger Blind Spot Warning Indicator Supply. General Electrical Failures. Circuit short to battery or open |
| PDM-B11F711 | Passenger Folding Mirror Motor. General Electrical Failures. Circuit short to ground |
| PDM-B11F715 | Passenger Folding Mirror Motor. General Electrical Failures. Circuit short to battery or open |
| PDM-B1A9511 | Passenger Mirror. General Electrical Failures. Circuit short to ground |
| PDM-B1A9515 | Passenger Mirror. General Electrical Failures. Circuit short to battery or open |
| PDM-B1A9883 | LIN Bus circuit #1. Bus Signal/Message Failures. Value of signal protection calculation incorrect |
| PDM-B1A9886 | LIN Bus circuit #1. Bus Signal/Message Failures. Signal invalid |
| PDM-B1A9887 | LIN Bus circuit #1. Bus Signal/Message Failures. Missing message |
| PDM-B1B7083 | LIN Bus Circuit #2. Bus Signal/Message Failures. Value of signal protection calculation incorrect |
| PDM-B1B7086 | LIN Bus Circuit #2. Bus Signal/Message Failures. Signal invalid |
| PDM-B1B7087 | LIN Bus Circuit #2. Bus Signal/Message Failures. Missing message |
| PDM-B1C1111 | Passenger Left/Right Mirror Motor Circuit. General Electrical Failures. Circuit short to ground |
| PDM-B1C1211 | Driver Up/Down Mirror Motor Circuit. General Electrical Failures. Circuit short to ground |
| PDM-B1C1511 | Passenger Up/Down Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to ground |
| PDM-B1C1515 | Passenger Up/Down Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to battery or open |
| PDM-B1C1611 | Passenger Left/Right Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to ground |
| PDM-B1C1615 | Passenger Left/Right Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to battery or open |
| PDM-B1C3929 | Key Lock Switch. General Signal Failures. Signal signal invalid |
| PDM-B1D0611 | Left Turn Indicator. General Electrical Failures. Circuit short to ground |
| PDM-B1D0615 | Left Turn Indicator. General Electrical Failures. Circuit short to battery or open |
| PDM-B1D0711 | Right Turn Indicator. General Electrical Failures. Circuit short to ground |
| PDM-B1D0715 | Right Turn Indicator. General Electrical Failures. Circuit short to battery or open |
| PDM-C1B1411 | Sensor Supply Voltage A. General Electrical Failures. Circuit short to ground |
| PDM-C1B1415 | Sensor Supply Voltage A. General Electrical Failures. Circuit short to battery or open |
| PDM-C1B1511 | Sensor Supply Voltage B. General Electrical Failures. Circuit short to ground |
| PDM-C1B1515 | Sensor Supply Voltage B. General Electrical Failures. Circuit short to battery or open |
| PDM-U014000 | Lost Communication With Central electronic module. General Failure Information. No sub type information |
| PDM-U020800 | Lost Communication With Power seat module. General Failure Information. No sub type information |
| PDM-U200224 | Switch. General Signal Failures. Signal stuck high |
| PDM-U200424 | Auxilliary Switch Pack. General Signal Failures. Signal stuck high |
| PDM-U201011 | Switch Illumination. General Electrical Failures. Circuit short to ground |
| PDM-U201208 | Car Configuration Parameter(s). General Failure Information. Bus Signal/Message Failures |
| PDM-U300362 | Battery Voltage. Algorithm Based Failures. Signal compare failure |