LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volvo >> 2013 >> C70 >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> Convertible Roof Module (CRM) DTCS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Convertible Roof Module (CRM) DTCS

CONVERTIBLE ROOF MODULE (CRM) - DTC INDEX

DTC Description
CRM-1011 Pushbutton Open Roof. Stuck in active position
CRM-1021 Pushbutton Close Roof. Stuck in active position
CRM-1031 Pushbutton Load Aid. Stuck in active position
CRM-2011 Hydraulic pump. Temperature sensor error
CRM-2021 Position encoder 17, front roof. Shorted to supply
CRM-2022 Position encoder 17, front roof. Ground (GND) short
CRM-2023 Position encoder 17, front roof. Invalid position
CRM-2024 Position encoder 17 (PE_FR). Activation timeout
CRM-2031 Hall sensor 5. Shorted to supply
CRM-2032 Hall sensor 5. Short to GND, disconnected or internal error
CRM-2033 Hall sensor 5. Invalid combination
CRM-2034 Hallsensor 5 (SL_FR_CR). Activation timeout
CRM-2041 Hall sensor 19. Shorted to supply
CRM-2042 Hall sensor 19. Short to GND, disconnected or internal error
CRM-2043 Hall sensor 19. Invalid combination
CRM-2044 Hallsensor 19 (SL_FR_C). Activation timeout
CRM-2051 Hall sensor 15. Shorted to supply
CRM-2052 Hall sensor 15. Short to GND, disconnected or internal error
CRM-2053 Hall sensor 15. Invalid combination
CRM-2054 Hallsensor 15 (SL_BIW_C). Activation timeout
CRM-2061 Position encoder 2, rear roof. Shorted to supply
CRM-2062 Position encoder 2, rear roof. Ground (GND) short
CRM-2063 Position encoder 2, rear roof. Invalid position
CRM-2064 Position encoder 2, rear roof. Activation timeout
CRM-2071 Hall sensor 6. Shorted to supply
CRM-2072 Hall sensor 6. Short to GND, disconnected or internal error
CRM-2073 Hall sensor 6. Invalid combination
CRM-2074 Hallsensor 6 (SL_RR_CL). Activation timeout
CRM-2081 Hall sensor 11. Shorted to supply
CRM-2082 Hall sensor 11. Short to GND, disconnected or internal error
CRM-2083 Hall sensor 11. Invalid combination
CRM-2084 Hallsensor 11 (SP_TC_R). Activation timeout
CRM-2091 Hall sensor 7. Shorted to supply
CRM-2092 Hall sensor 7. Short to GND, disconnected or internal error
CRM-2093 Hall sensor 7. Invalid combination
CRM-2094 Hallsensor 7 (SL_TL_CL). Activation timeout
CRM-20A1 Hall sensor 1. Shorted to supply
CRM-20A2 Hall sensor 1. Short to GND, disconnected or internal error
CRM-20A3 Hall sensor 1. Invalid combination
CRM-20A4 Hallsensor 1 (SL_FR_CL). Activation timeout
CRM-20B1 Hall sensor 3. Shorted to supply
CRM-20B2 Hall sensor 3. Short to GND, disconnected or internal error
CRM-20B3 Hall sensor 3. Invalid combination
CRM-20B4 Hallsensor 3 (SP_BL_FO). Activation timeout
CRM-20C1 Hall sensor 18. Shorted to supply
CRM-20C2 Hall sensor 18. Short to GND, disconnected or internal error
CRM-20C3 Hall sensor 18. Invalid combination
CRM-20C4 Hallsensor 18 (SL_FR_0). Activation timeout
CRM-20D1 Hall sensor 13. Shorted to supply
CRM-20D2 Hall sensor 13. Short to GND, disconnected or internal error
CRM-20D3 Hall sensor 13. Invalid combination
CRM-20D4 Hallsensor 13 (SD_TL_C). Activation timeout
CRM-20E1 Hall sensor 16. Shorted to supply
CRM-20E2 Hall sensor 16. Short to GND, disconnected or internal error
CRM-20E3 Hall sensor 16. Invalid combination
CRM-20E4 Hallsensor 16 (SL_BIW_0). Activation timeout
CRM-20F1 Hall sensor 10. Shorted to supply
CRM-20F2 Hall sensor 10. Short to GND, disconnected or internal error
CRM-20F3 Hall sensor 10. Invalid combination
CRM-2101 Hall sensor 9. Shorted to supply
CRM-2102 Hall sensor 9. Short to GND, disconnected or internal error
CRM-2103 Hall sensor 9. Invalid combination
CRM-2104 Hallsensor 9 (SD_TL_O). Activation timeout
CRM-2111 Hall sensor 12. Shorted to supply
CRM-2112 Hall sensor 12. Short to GND, disconnected or internal error
CRM-2113 Hall sensor 12. Invalid combination
CRM-2114 Hallsensor 12 (SP_TC_E). Activation timeout
CRM-3011 Open calibration not performed
CRM-3012 Closed calibration not performed
CRM-4011 Implausible sensor state 9 (SL_TL_O) and 13 (SL_TL_C)
CRM-4012 Implausible sensor state 16 (SL_BIW_O) and hallsensor 15 (SL_BIW_C)
CRM-4013 Implausible sensor state 11 (SP_TC_R) and 12 (SP_TC_E)
CRM-4014 Implausible sensor state 18 (SL_FR_O) and 19 (SL_RL_C)
CRM-4015 Implausible sensor state 18 (SL_FR_O) and 5 (SL_FR_C)
CRM-4016 Implausible sensor state 18 (SL_FR_O) and 1 (SL_TL_CL)
CRM-4017 Implausible sensor state 6 (SL_RR_CL) and 17 (PE_FR)
CRM-4018 Implausible sensor state 2 (PE_MR) and 17 (PE_FR)
CRM-6011 Valve 1. Signal too high/signal too low
CRM-6021 Valve 2. Signal too high/signal too low
CRM-6031 Valve 3. Signal too high/signal too low
CRM-6041 Valve 4. Signal too high/signal too low
CRM-6051 Antenna output. Shorted to supply
CRM-6052 Antenna output. Ground (GND) short
CRM-C011 Convertible Roof Module (CRM). Internal fault
CRM-C012 Convertible Roof Module (CRM). Internal fault
CRM-C021 Convertible Roof Module (CRM). Internal fault
CRM-C022 Convertible Roof Module (CRM). Internal fault
CRM-C031 Convertible Roof Module (CRM). Internal fault
CRM-C032 Convertible Roof Module (CRM). Internal fault
CRM-C042 Control module. Internal fault
CRM-C051 Convertible Roof Module (CRM). Internal fault
CRM-C052 Hydraulic pump. Supply voltage too low
CRM-C053 Hydraulic pump. Signal missing
CRM-C061 Convertible Roof Module (CRM). Internal fault
CRM-C062 Convertible Roof Module (CRM). Internal fault
CRM-C071 Control module. Relays defect
CRM-C072 Catch motor. Motor blocked
CRM-C073 Control module. Relays defect
CRM-C100 Control module, memory fault. Internal fault
CRM-E001 Control module communication. Faulty communication
CRM-E003 Configuration fault. Faulty configuration
CRM-E010 Power supply. Signal too low