Cranking Test

  1. Connect a voltmeter and ammeter to battery. See Fig 1 . Disconnect 2-pin connector from distributor. Ignition control module is located on right strut tower.
  2. Use remote starter switch to crank engine. Check cranking voltage and current draw. Ensure voltage is at least 8 volts. Current draw should be less than 350 amps. Cranking speed should be greater than 100 RPM.
Fig 1: Connecting Voltmeter & Ammeter For Cranking Test
G96G06241Courtesy of AMERICAN HONDA MOTOR CO., INC.