LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Acura >> 1998 >> Integra GS-R, 4D Sedan >> Repair and Diagnosis >> Electrical >> Starters >> On-Vehicle Testing >> Cranking Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Cranking Test

  1. Connect a voltmeter and ammeter to battery. See Fig 1. On Integra, remove fuse No. 44 from underhood fuse/relay box. On 3.2TL and 3.5RL, disconnect 8-pin and 6-pin connectors from ignition control module. Ignition control module is located on right strut tower. On SLX, disconnect two 3-pin connectors and one 4-pin connector from ignition control module. Ignition control module is located on rear of intake manifold. On 2.5TL disconnect 4-pin connector from ignition coil. Ignition coil is located on firewall, behind right strut tower.
  2. On all models, use remote starter switch to crank engine. Check cranking voltage and current draw. Ensure voltage is at least 8 volts. Current draw should be less than 350 amps. Cranking speed should be greater than 100 RPM.
Fig 1: Connecting Voltmeter & Ammeter For Cranking Test
G96G06241Courtesy of AMERICAN HONDA MOTOR CO., INC.