Climate Control Panel Circuit Troubleshooting
- Check the No. 3 (7.5 A) fuse in the driver's underdash fuse/relay box.
Is the fuse OK?
- YES - Go to step 2.
- NO - Replace the fuse and recheck.
- Disconnect the climate control panel 16P connector.
- Turn the ignition switch ON (II).
- Measure the voltage between the No. 7 terminal of climate control panel 16P connector and body ground.Fig 1: Measuring Voltage Between No. 7 Terminal Of Climate Control Panel 16P Connector And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
- YES - Go to step 5.
- NO - Repair open in the wire between the No. 3 fuse in the driver's underdash fuse/relay box and the climate control panel.
- Turn the ignition switch OFF.
- Disconnect climate control unit connectors A (16P) and B (26P).
- Check for continuity between the following terminals of the climate control panel 16P connector and climate control unit connectors A (16P) and B (26P).TERMINALS REFERENCE
PANEL 16P UNIT 16P No. 5 No. 12 No. 6 No. 14 No. 14 No. 13 PANEL 16P UNIT 26P No. 12 No. 16 Courtesy of AMERICAN HONDA MOTOR CO., INC.
Fig 3: Checking For Continuity Between Terminals Of Climate Control Unit Connectors A (16P) And B (26P)Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
- YES - Go to step 8.
- NO - Repair any open in the wire(s) between the climate control panel and climate control unit.
- Check the continuity between the No. 5, 6, and 14 terminals of the climate control panel 16P connector and body ground individually.Fig 4: Checking Continuity Between No. 5, 6, And 14 Terminals Of Climate Control Panel 16P Connector And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
- YES - Repair any short to body ground in the wire(s) between the climate control panel and the climate control unit.
- NO - Check for loose wires or poor connections at climate control unit connector A (16P) and B (26P) and at the climate control panel 16P connector. If the connections are good, substitute a known-good climate control panel, and recheck. If the symptom/indication is still present, substitute a known-good climate control unit, and recheck.