October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Engine Lubrication
| Oil pump | Inner-to-outer rotor clearance | | Standard or new | 0.02 - 0.15 mm |
| | | Service limit | 0.20 mm |
| Pump housing-to-outer rotor clearance | | Standard or new | 0.15 - 0.21 mm |
| | | Service limit | 0.23 mm |
| Pump housing-to-rotor axial clearance | | Standard or new | 0.02 - 0.07 mm |
| | | Service limit | 0.12 mm |
| Relief valve, oil pressure with oil temperature at 176 deg F (80 deg C) | At idle | Standard or new | 70 kPa Minimum |
| | At 3,000 rpm | Standard or new | 300 kPa Minimum |