Audio System Information Does Not Display On The Display Panel (Without Navigation) Or Audio-HVAC Subdisplay Unit (With Navigation). The HVAC controls may also be affected.
- Check for DTCs in the display module control unit.
Are there any DTCs?
- YES - Troubleshoot the DTCs.
- NO - Go to step 2.
- Disconnect display panel control unit connector A (14P).
- Disconnect audio unit connector C (26P).
- Check for continuity between audio unit connector C (26P) terminals and display panel control unit connector A (14P) terminals according to the table.AUDIO UNIT SPECIFICATIONS
Audio unit terminal Display panel control unit (14P) terminal Wire color C26 A11 RED C13 A3 BLU C9 A8 BLU/WHT C8 A9 GRN/ORN Is there continuity?
- YES - Go to step 5.
- NO - Repair an open in the wire between the audio unit and the display panel control unit.
- Check for continuity between audio unit connector C (26P) terminals in the table and body ground. Then check for continuity between the terminals in the table and audio connector C (26P) No. 12 terminal (the harness shield).AUDIO UNIT SPECIFICATIONS
Audio unit (26P) terminal Wire color C26 RED C13 BLU C9 BLU/WHT C8 GRN/ORN Is there continuity?
- Substitute a known-good display panel.
- Reconnect all connectors.
- Check the display.
Does the display operate properly?
- YES - Replace the display panel control unit (see DISPLAY PANEL CONTROL UNIT REMOVAL/INSTALLATION ).
- NO - Replace the audio unit (see AUDIO UNIT REMOVAL/INSTALLATION ).
- Check the connections at the audio-HVAC subdisplay unit connector (10P) and the display panel control unit connector E (22P).
Are the connectors and terminals connected properly?
- YES - Go to step 10.
- NO - Repair the connection and recheck.
- Disconnect the audio-HVAC subdisplay unit connector (10P).
- Disconnect the display panel control unit connector E (22P).
- Check for continuity between the audio-HVAC subdisplay unit connector (1 OP) and the display panel control unit connector E (22P) terminals for each wire listed in the table.AUDIO-HVAC SPECIFICATIONS
Audio-HVAC subdisplay unit connector (10P) terminal Display panel control unit connector (22P) terminal Wire Color 2 E20 BLU/ORN 4 E22 YEL/RED 5 E21 YEL 6 E10 BLU/RED 7 E9 BLU 8 E8 BRN/BLK 9 E19 RED 10 E18 RED/BLU Is there continuity?
- YES - Go to step 13.
- NO - Repair an open in the wire between the display panel control unit and the audio-HVAC subdisplay unit.
- Check for continuity between each audio-HVAC subdisplay unit connector (10P) terminal and body ground according to the table. Then check for continuity between the terminals in the table and audio connector C (26P) No. 12 terminal (the harness shield).AUDIO-HVAC SPECIFICATIONS
Audio-HVAC subdisplay unit connector (10P) terminal Wire Color 2 BLU/ORN 4 YEL/RED 5 YEL 6 BLU/RED 7 BLU 9 RED 10 RED/BLU Is there continuity?
- YES - Repair the short to ground in the wire between the display panel control unit and the audio-HVAC subdisplay unit, or replace the appropriate shielded harness.
- NO - Go to step 14.
- Substitute a known-good audio-HVAC subdisplay unit and recheck.
Does the subdisplay work properly?
- YES - Replace the original audio-HVAC subdisplay unit.
- NO - Substitute a known-good display panel control unit and retest. If the problem is gone, replace the original display panel control unit.