EPS Control Unit Inputs and Outputs for Connector A (2P) (Connector Disconnected)
CONNECTOR TERMINALS DESCRIPTION CHART
| Terminal number | Wire color | Terminal sign | Description | Signal |
|---|---|---|---|---|
| 1 | BLK | PG (Power ground) | Ground for the actuator EPS motor | Continuity to ground |
| 2 | WHT | +B (Plus battery) | Power source for the actuator EPS motor | Battery voltage at all times |