Altitude COMPENSATOR Sensor
Disconnect wiring from sensor. Measure resistance between terminals No. 2 and 3. Measure resistance between terminals No. 1 and 2. If resistance values are not as specified, replace sensor.
ALTITUDE COMPENSATOR SPECIFICATIONS
| Terminals | Ohms | |
|---|---|---|
| 2-3 | 2000-3000 | |
| 1-2 | ||
| At 0-4000 Ft. | 500-4500 | |
| Above 4000 Ft. | 2500-6000 | |
NOTE:
For all other models, refer to appropriate article in 1988 COMPUTERIZED ENGINE CONTROLS section.