Acc Alignment Procedure

NOTE:

Special tool 2014000080 is available through a rental program. For additional details visit the Mopar® Essential Tool website.

This procedure must be performed in the following cases:

Preparation Measure  - The following steps must be performed before beginning the control and adjustment of the sensor / proximity radar:

GC0169593Courtesy of CHRYSLER GROUP, LLC
  1. Follow the instructions included in the special tool 2014000080 container for proper unboxing.
    GC0169298Courtesy of CHRYSLER GROUP, LLC
  2. Verify the proper tools and components are in the shipping container. The following items are included: plumb bob, tape measure, snap line, chalk bottle, and the laser for the mirror.
    GC0169400Courtesy of CHRYSLER GROUP, LLC
  3. Assemble the alignment tool following the instructions included in the shipping container.
  4. Once the tool is properly assembled, set it aside while performing the measurement procedure.
  5. To get the mirror in proper position, it may be necessary to disconnect the clip (1). Take great care that the mirror does not drop to prevent damage.
    GC0196468Courtesy of CHRYSLER GROUP, LLC
  6. Find the center of each wheel, mark the floor for each wheel using the plumb bob. The plumb bob must be the same distance out from each wheel/tire.
    GC0196115Courtesy of CHRYSLER GROUP, LLC
  7. Use the chalk line to snap a line on both the left and right side of the vehicle along the marks made with the plumb bob in the previous step. Extend the line that is snapped at least 3 meters (10 feet) in front of the center of the front wheels. This will allow room to properly position the alignment tool.
    GC0197151Courtesy of CHRYSLER GROUP, LLC
  8. Remove the trim cover for the alignment sensor.
  9. Find the horizontal center of the sensor and use the plumb bob to mark the location on the floor.
    GC0196364Courtesy of CHRYSLER GROUP, LLC
  10. Measure from the passenger side chalk line to the sensor horizontal center mark. This will be the same distance that the center of the sensor tool will be placed on the front chalk line.
  11. Snap a line that is 90 degrees perpendicular to the side chalk lines and that runs through the mark for the sensor horizontal center.
    GC0197362Courtesy of CHRYSLER GROUP, LLC
  12. Measure 120 cm from the horizontal center of the sensor (1) to a line (3) that is perpendicular to the side chalk lines. Measure and mark the distance (2) that the passenger side chalk line was from the sensor horizontal center.
    GC0195861Courtesy of CHRYSLER GROUP, LLC
  13. Position the sensor tool with the center lined up with the mark on the front line. Install the laser and align the beam with the chalk line.
    GC0169397Courtesy of CHRYSLER GROUP, LLC
  14. There are adjusters at the front and rear of the base of the sensor to level the tool.
    GC0169419Courtesy of CHRYSLER GROUP, LLC
  15. With the tilt cam in the 0 degree position, adjust the tool until the bubble is in the center of the level.
  16. Measure from the horizontal mark on the floor to the vertical center of the sensor.
    GC0169538Courtesy of CHRYSLER GROUP, LLC
  17. Set the height of the center of the mirror at the same height as the vertical center of the sensor.
    GC0195861Courtesy of CHRYSLER GROUP, LLC
  18. Verify that the laser is still lined up with the front chalk line. Then make sure the bubble is still in the middle of the level with the tilt cam in the 0 degree position.
  19. Turn off the laser and remove it from the mirror.
  20. Use the scan tool to perform the alignment procedure.

THE SENSOR / RADAR PROXIMITY  - The calibration procedure involves performing three measurements, each time changing the angle of the reflecting mirror. To adjust the angle, tilt the mirror forward and then turn the tilt cam to the desired position.

GC0195619Courtesy of CHRYSLER GROUP, LLC
NOTE:

For vertical and horizontal radar, follow the directions given from the diagnostic scan tool.

GC0195697Courtesy of CHRYSLER GROUP, LLC

SCREW POSITION 1: screw shown in the illustration for vertical adjustment (1)

SCREW POSITION 2: screw shown in the illustration for horizontal adjustment (2)