Closed Loop Operation
When all input data, on engine operation, meets programmed criteria (Open Loop conditions do not exist), the system switches to Closed Loop Operation mode. This then allows oxygen sensor input to MCU to determine proper air/fuel ratio. In this mode, all sensors supply engine operating conditions and demands to MCU. The sensor signals are computed and modified by oxygen sensor signal for optimum air/fuel mixture.