Reverse Delay Valve
Apply a constant vacuum of 10 in. Hg to colored end on delay valve. Attach a vacuum gauge (using a 24 INCH section of vacuum hose) to white end of valve. Count time in seconds for vacuum gauge to read 8 in. Hg with a constant vacuum of 10 in. Hg applied to colored end of valve. Compare times with those in table. If incorrect, replace valve.
Reverse Delay Valve Flow Test
| Color | Minimum | Time in Seconds Maximum |
|---|---|---|
| White/Gray | 0.6 | 1.6 |
| White/Brown | 1.0 | 3.0 |
| White/Gold | 0.6 | 2.3 |
| White/Red | 13.0 | 15.0 |
| White/Purple | 0.3 | 1.0 |