Checking Electrically
- Disconnect EVAP canister purge regulator valve harness connector. See Figure.
- Switch DVOM multimeter to resistance range.
- Connect multimeter between EVAP canister purge regulator valve terminals. See Fig 1. Resistance must be 40-50 ohms.
- If resistance is incorrect, replace EVAP canister purge regulator valve.
Courtesy of AUDI OF AMERICA, INC.