TID 01 ($01): Catalytic Conversion (Bank 1)
- Connect the scan tool.
- Start the engine and run at idle.
- Select "Mode 6: Check test the results of components that are not continuously monitored".
Select "Test-ID 01 ($01) ".
- Select the desired "Component-ID (CID)" or "Hex-ID".
- Check specified values at idle.
| Component-ID (CID) (Hex-ID) | DTC | Component or System | Min. | Max. | Additional Information |
|---|---|---|---|---|---|
| 05 ($05) | P0420 | Conversion Capability (storage) Check. | --- | > 2 | Refer to DTC P0420 in the OBD DTC Summary Table for all monitoring values. P0420 . |
| 07($07) | P0420 | Conversion Capability (storage) Check. | --- | > 2 | Refer to DTC P0420 in the OBD DTC Summary Table for all monitoring values. P0420 . |
| 08($08) | P0420 | Conversion Capability (storage) Check. | --- | > 2 | Refer to DTC P0420 in the OBD DTC Summary Table for all monitoring values. P0420 . |
- If any of components or systems fail to meet the specified values. Refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTCs or the corresponding diagnostic repair procedure → Mode 03: Interrogating fault memory .
- Switch the ignition off.
- End of diagnosis.