Read Measuring Value Blocks, interpreting
| Read Measuring Value Block 20 | → | ← Indicated on display (example only) | ||||
| AU | Z5 | 0W | 10 | |||
Immobilizer Identification No.1)
|
||||||
Immobilizer Identification No.1)
|
||||||
Immobilizer Identification No.1)
|
||||||
Immobilizer Identification No.1)
|
||||||
1) Read function where applicable
| Read Measuring Value Block 21 | → | ← Indicated on display (example only) | ||||
| 00 | 00 | 71 | ||||
| vacant | ||||||
Immobilizer Identification No.1)
|
||||||
Immobilizer Identification No.1)
|
||||||
Immobilizer Identification No.1)
|
||||||
| AUZ5Z0W1000071 | ||||||
1) Read function where applicable
| Read Measuring Value Block 22 | → | ← Indicated on display | ||||
| X | X | X | X | |||
Number of adapted keys
|
||||||
Key condition OK
|
||||||
Engine Control Module (ECM) responding
|
||||||
Start procedure permitted
|
||||||
1) Depending on the Engine Control Module (ECM), the measuring value block registers position "0 = Engine Control Module not responding" for 10 to 30 seconds after engine and ignition are switched off, i.e. ECM is switched clear and there is no malfunction. Initiate On Board Diagnostic (OBD) again to be sure. Refer to Anti-theft immobilizer On Board Diagnostic (OBD), initiating .
| Read Measuring Value Block 23 | → | ← Indicated on display | ||||
| X | X | X | X | |||
Anti-theft immobilizer status
|
||||||
Fixed code authorized
|
||||||
Key status (transponder)
|
||||||
Variable code authorized
|
||||||
| Read Measuring Value Block 24 | → | ← Indicated on display | ||||
| XX | X | XX | ||||
The transponder recognition locking time indicates how much time must pass before a transponder recognition is possible again. This lock is activated after an unauthorized key is detected 20 times in a row.
|
||||||
| vacant | ||||||
The Engine Control Module (ECM) locking time indicates how much time must pass before an adaptation can be performed by the Engine Control Module again. If the 7-digit PIN is entered incorrectly three times while adapting channel 50, the control module is locked for 10 minutes 2).
|
||||||
The instrument cluster locking time indicates how much time must pass before a login procedure can be performed again. If the 7-digit PIN is entered incorrectly three times during the login procedure (adaptation of vehicle key or used instrument cluster), the control module is locked for 10 minutes 1).
|
||||||
1) Read function where applicable.
2) This time is doubled after every third consecutive incorrect attempt, up to a maximum of 255 minutes.
| Read Measuring Value Block 25 | → | ← Indicated on display | ||||
| X | ||||||
CAN-communication to Engine Control Module (ECM)1)
|
||||||
1) Read function where applicable