Home >> Audi >> 2004 >> TT Base, 2D Convertible >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating & Air Conditioning >> 01 On Board Diagnostic (OBD) >> Automatic Climate Control system, On Board Diagnostic (OBD) >> Read Measuring Value Block (function 08) >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Read Measuring Value Block (function 08): Notes

NOTE:
  • A/C control heads -E87- with part numbers without index letter have 10 measuring value blocks (display groups), each showing 4 measuring values (display fields).
  • A/C control heads -E87- with part numbers including index letter "A", and onward have 11 measuring value blocks (display groups), each showing 4 measuring values (display fields).
  • Regulation of the air conditioning remains functional during the On Board Diagnostic (OBD) Read Measuring Value Block" function 08 and the current measured values are displayed.
  • Display groups 2 through 5 show the current actual or specified values and the learned values (stored during the last basic setting) for the end stops of the individual positioning motors.
  • The positions of the positioning motors and flaps can be changed during the OBD using the control buttons on the A/C Control Head-E87-, and the current actual and specified values are displayed on the VAG 1551 Scan Tool (ST).
  • If the printer is switched on, the current display will be printed out.

Read Measuring Value Block (function 08), initiating 

Rapid data transfer HELP
Select function XX

Indicated on display

Rapid data transfer Q
08 - Read Measuring Value Block

Indicated on display

Read Measuring Value Block
Input display group number XXX

Indicated on display

Read Measuring Value Block X →
1 2 3 4

Indicated on display

To select another display group:

Read Measuring Value Block
Input display group number XXX

Indicated on display

NOTE: Pressing the -3- button advances the program to the next display group. Pressing the -1- button moves the program back by one display group.

If all the display fields show the specified values:

Rapid data transfer HELP
Select function XX

Indicated on display