Coolant Fan Control (FC) Module -J293-, electrical testing: Notes
Special tools, testers and auxiliary items
- Multimeter (Fluke 83 or equivalent)
- VW 1594 connector test kit
- VAG 1527B voltage tester (or equivalent diode type tester)
- VAS 5051 Vehicle Diagnostic Testing and Information System for testing square wave (pressure) signal on vehicles with high pressure sensor -G65-.
Test conditions
- All fuses OK according to wiring diagram
- DTC memory of A/C Control Head -E87- checked - no DTCs stored.
- No compressor shut-off conditions displayed in read measuring value block (Display Group 01, display field 1) for A/C Control Head -E87- while engine is running.
- A/C Control Head -E87- installed.
- Connectors A and B detached from -J293-.
Coolant Fan Control (FC) Module -J293- (vehicles with A/C pressure switch -F129-), electrical testing
Terminal assignments at -J293- (vehicles with -F129-)
Location: In engine compartment on left long member.
Function:
- Activates coolant fan(s) -V7- (speeds 1 and 2)
- Activates A/C clutch -N25-.
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations.
Terminal assignments and switching conditions (A/C pressure switch -F129-)
- Switch between terminals -1- and -2- opens if there is excess pressure or insufficient refrigerant system pressure (A/C clutch -N25- is disengaged).
- Switch between terminals -3- and -4- closes when refrigerant system pressure rises (coolant fan(s) -V7- switched to speed 2).
Switching conditions - Coolant Fan Control (FC) Thermoswitch -F18/-F54
- -F54 between terminals 1 and 2: Closes at approx. 95 °C (-V7- switched to speed 1).
- -F18 between terminals 3 and 2: Closes at approx. 102 °C (-V7- switched to speed 2).
Switching conditions - Engine Coolant Temperature (ECT) Waring Switch -F14-
- Switch opens at approx. 118 °C - compressor is switched off.
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations.
Test step 1 - Voltage supply, Ground (GND) supply
| Voltage test - switch to 20 V measuring range | ||||||
| Test step | -J293- connectors/terminals | Test of |
|
Specified Value |
Corrective action | |
| 1.1 | B/3 + A/6 | Voltage supply | Approx. B+ |
|
||
| 1.2 | B/4 + A/6 | Voltage supply | Approx. B+ |
|
||
| 1.3 | A/4 + A/6 | Voltage supply | Approx. B+ |
|
||
| 1.4 | A/9 + A/6 | Voltage supply |
|
Approx. B+ |
|
|
Test step 2 - Activation of coolant fan(s) -V7-
| Voltage test - switch to 20 V measuring range | ||||||
| Test step | -J293- connectors/terminals | Test of |
|
Specified Value |
Corrective action | |
| 2.1 | A/5 + A/6 | -V7- speed 1 signal from A/C Control Head -E87- (activated by -E87-) |
|
Approx. B+ |
|
|
| 2.2 | A/2+ A/6 | -V7- speed 2 signal from -E87- (activated by A/C pressure switch -F129-) |
|
Approx. B+ |
|
|
Test step 2 continued:
| Voltage test - switch to 20 V measuring range | ||||||
| Test step | -J293- connectors/terminals | Test of |
|
Specified Value |
Corrective action | |
| 2.3 | Connectors A + B connected to -J293- | -V7- speed 2 (activated by A/C pressure switch -F129-) |
|
-V7- runs (speed 2) |
|
|
| 2.4 | B/2 + A/6 | -V7- speed 1 signal from -E87- (activated by Coolant Fan Control (FC) Thermoswitch -F54- |
|
Approx. B+ -V7- runs (speed 1) |
|
|
Test step 2 continued:
| Voltage test - switch to 20 V measuring range | ||||||
| Test step | -J293- connectors/terminals | Test of |
|
Specified Value |
Corrective action | |
| 2.5 | A/7 + A/6 | -V7- speed 2 signal from -E87- (activated by Coolant Fan Control (FC) Thermoswitch -F18-) |
|
Approx. B+ |
|
|
| 2.6 | Connectors A + B connected to -J293- | -V7- speed 2 signal from -E87- (activated by Coolant Fan Control (FC) Thermoswitch -F18-) |
|
Approx. B+ -V7- runs (speed 2) |
|
|
Test step 3 - Activation of A/C clutch -N25-
| Voltage test - switch to 20 V measuring range | ||||||
| Test step | -J293- connectors/terminals | Test of |
|
Specified Value |
Corrective action | |
| 3.1 | A/8 + A/6 | Signal from A/C Control Head -E87- ("activate A/C clutch -N25-") |
|
Approx. B+ |
|
|
Test step 3 continued:
| Current test - switch to 20 A measuring range | ||||||
| Test step | -J293- connectors/terminals | Test of |
|
Specified Value |
Corrective action | |
| 3.2 | A/4 + A/10 | Activation of A/C clutch -N25- |
|
< 10 amp -N25- clicks when voltage applied |
|
|
Coolant Fan Control (FC) Module -J293- (vehicles with high pressure sensor -G65-), electrical testing
Terminal assignments at -J293- (vehicles with -G65-)
Location: In engine compartment on left long member
Function:
- Activates coolant fan (s) -V7 (speeds 1 and 2)
- Activates A/C clutch -N25
- Processes the square-wave signal from high pressure sensor -G65- and sends a positive signal to -E87- to indicate the refrigerant system pressure is OK.
- Switches on after-run coolant pump -V51 (if equipped) for continued coolant circulation when the ignition is switched on. The pump continues to operate for a short time after the ignition has been switched off.
- The following -J293- connector A terminals are vacant:
Terminal 1 (on vehicles without after-run coolant pump -V51-)
Terminals 3, 5, 11 and 14
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
- -J293- connector A,, terminal 13 is intended for disengaging -A/C clutch -N25- when the instrument cluster sends "excessive coolant temperature" signal. As disengagement of -N25- also takes place via the A/C Control Head -E87-, -J293- terminal 13 may be vacant on some vehicles, dependant of vehicle wiring configuration.
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
- The function of Coolant Fan Control (FC) Module -J293 and vehicle wiring layout will vary depending on whether vehicle is equipped with A/C pressure switch -F129 or high pressure sensor -G65-.
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
- Various versions of Coolant Fan Control (FC) Module -J293-, used in conjunction with high pressure sensor -G65- may be installed. At the time of publishing however, All TT equipped with -J293-/-G65- have version where coolant fan(s) -V7- speed 1 is always switched on automatically whenever the A/C clutch -N25- is energized (regardless of refrigerant system pressure).
Terminal assignments and switching conditions (high pressure sensor -G65-)
Terminal -1- Ground (GND)
Terminal -2- Signal output (square-wave signal to -J293- and ECM)
Terminal -3- Positive (terminal 15)
- When electrical connector at -B- is disconnected, the A/C clutch -N25- cannot be activated.
- High pressure sensor -A- transmits a square-wave signal at a pulse rate that varies according to the refrigerant system pressure. Checking. Refer to High pressure sensor -G65- signal, checking .
Switching conditions - Coolant Fan Control (FC) Thermoswitch -F18/-F54
- -F54- between terminals 1 and 2: Closes at approx. 95 °C (-V7- switched to speed 1).
- -F18- between terminals 3 and 2: Closes at approx. 102 °C (-V7- switched to speed 2).