Home >> Audi >> 2006 >> A3 Base, Standard >> Repair and Diagnosis >> Engine Performance >> System >> 2.0L - Generic Scan Tool - Engine Code(S): BPY >> St Generic Scan Tool >> Diagnosis And Testing >> Diagnostic Modes 01 - 09 >> Diagnostic Mode 06 - Read Test Results For Specific Diagnostic Functions >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Mode 06 - Read Test Results For Specific Diagnostic Functions: Notes

Diagnostic Mode 06 makes it possible to retrieve test results for special components and systems which are continuously or not continuously monitored. If the diagnosis of a system is complete, the diagnostic result and the corresponding thresholds are saved and displayed in mode 06. This data remains saved (even with the ignition off) until either new diagnostic results become available or the DTC memory is erased.

The min & max values for each individual test in Mode 06 represent the min & max operating values for a properly operating system. This data is provided to the individual aftermarket scan tool companies for development of their scan tool. Depending on the scan tool being used, the min & max values shown may vary, or be rounded up or down to the nearest decimal point depending on the aftermarket scan tool company's development process. e.g.:

  Minimum Value
GST Manual documentation 0.3499
Aftermarket Scan Tool display 0.35

Depending on the scan tool and protocol used, the information displayed in Diagnostic Mode 06 may be referred to by different names such as Test-ID (CID), Hex-ID, Component-ID (CID), On-Board Diagnostic Monitor Identifier (OBDMID), or contain no name at all and may be referenced by only a number.

Test requirements 

Work procedure 

-- Connect the scan tool.

-- Start the engine and run at idle.

NOTE:

If the engine does not start, crank the engine using starter for at least 5 seconds, do not switch the ignition off afterward under any circumstances.

-- Select "Mode 6: Check test the results of components that are not continuously monitored".

-- Select the desired "Test-ID" of the component or system that is to be monitored, e.g. "Test-ID 01: Oxygen Sensor Monitor Bank 1 - Sensor 1".

-- Select the desired "Test-ID".

The current minimum and maximum values will be displayed on the scan tool screen.

The following table is a numerical list of all "Test-IDs" or "Hex-IDs" that may be selected.

Test-ID (Hex-ID) Component or System
01 ($01):Test-ID 01 ($01): Oxygen Sensor Monitor Bank 1 - Sensor 1  Oxygen Sensor Monitor Bank 1 - Sensor 1
02 ($02):Test-ID 02 ($02): Oxygen Sensor Monitor Bank 1- Sensor 2  Oxygen Sensor Monitor Bank 1 - Sensor 2
33 ($21):Test-ID 33 ($21): Catalytic Converter Monitoring  Catalytic Converter Monitoring
58 ($3A):Test-Id 58 ($3A): Fuel Tank Evap System Integrity/Leak Test (0.90&Rdquo;)  Fuel Tank EVAP System Integrity/Leak Test (0.90")
59 ($3B):Test-ID 59 ($3B): Fuel Tank EVAP System Integrity/Leak Test (0.40/1.0mm)  Fuel Tank EVAP System Integrity/Leak Test (0.40/1.0mm)
60 ($3C):Test-ID 60 ($3C): Fuel Tank EVAP System Integrity/Leak Test (0.20/0.5mm)  Fuel Tank EVAP System Integrity/Leak Test (0.20/0.5mm)
61 ($3D):Test-ID 61 ($3D): EVAP Valve Function Check  EVAP Valve Function Check
65 ($41):Test-ID 65 ($41): Oxygen Sensor Heater Monitor Bank 1 - Sensor 1  Oxygen Sensor Heater Monitor Bank 1 - Sensor 1
66 ($42):Test-ID 66 ($42): Oxygen Sensor Heater Monitor Bank 1 - Sensor 2  Oxygen Sensor Heater Monitor Bank 1 - Sensor 2
162 ($A2):Test-ID 162 ($A2): Mis-Fire Cylinder 1 Data  Mis-Fire Cylinder 1 Data
163 ($A3):Test-ID 163 ($A3): Mis-Fire Cylinder 2 Data  Mis-Fire Cylinder 2 Data
164 ($A4):Test-ID 164 ($A4): Mis-Fire Cylinder 3 Data  Mis-Fire Cylinder 3 Data
165 ($A5):Test-ID 165 ($A5): Mis-Fire Cylinder 4 Data  Mis-Fire Cylinder 4 Data