Seat control element, basic setting: Notes
Basic setting must be performed if seat components are replaced.
Test requirements:
- Voltage supply and fuses for the appropriate system OK.
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
- Connect VAS 50511 Scan Tool (ST). Refer to VAS 5051 Scan Tool (ST), connecting .
Procedure
- Move backrest as far forward as possible.
- Check the existing value in Measuring Value Block 002. Refer to Read Measuring Value Block (function 08) .
| Read measured value block 2 → Not operated 32767 forward 34231 |
Indicated on display (example values):
Display zone 4 will show current value (in example 34231).
- Note this value.
- Move backrest back toward its normal seating position until the setting is 1082 units less than the original value (in example: 34231 minus 1082 = 33149).
- Start basic setting.
Implementing function "04 - Basic setting"
| Rapid data transfer HELP Select function XX |
Indicated on display:
- Press buttons -0- and -4-.
| Rapid data transfer Q 04 - Basic setting |
Indicated on display:
- Confirm entry with -Q- button.
| Basic setting Enter display group number XXX |
Indicated on display:
- Press buttons -0-, -0- and -1-.
| Basic setting Q Enter display group number 001 |
Indicated on display:
- Confirm entry with -Q- button.
| System in basic setting 1 Basic value learned |
Indicated on display:
- Basic setting complete.
- Press the → button.
| Rapid data transfer HELP Select function XX |
Indicated on display:
- Check display zone 4 in measured value block 002. The display should show the numerical value for the central position (i.e. 32767).
- Check the basic setting as follows:
- Move the backrest as far back as possible.
- Press the "memory" button and one of the personalized buttons (e.g. memory location 1).
- With the driver's door open, press the selected personalized button again (e.g.: 1). The backrest will move back automatically to the rearmost position.
Deactivating remote control key memory function
In basic setting 004, all (simultaneously) memory functions for all 4 remote control key are erased.
Test requirements:
- Voltage supply and fuses for the appropriate system OK.
Refer to Electrical Wiring Diagrams, Troubleshooting & Component Locations
- Connect VAS 5051 Scan Tool (ST). Refer to VAS 5051 Scan Tool (ST), connecting .
Procedure
| Basic setting Enter display group number XXX |
Indicated on display:
- Press buttons -0-, -0- and -4-.
| Basic setting Q Enter display group number 004 |
Indicated on display:
- Confirm entry with -Q- button.
| System in basic setting 4 Basic value learned |
Indicated on display:
- Basic setting is complete.
- Press the → button.
| Rapid data transfer HELP Select function XX |
Indicated on display:
- Check display value 4 in measured value block 001. The display must show 0000 when the "open" button is actuated on the remote control key.
- Check the function as follows:
- Lock the vehicle.
- Unlock the vehicle using the remote control key.
- The driver's seat adjustment must not change when the driver's door is opened.