| P0600 |
Serial Communication Link |
|
Short to battery positive Short to ground Core connection ECM receiving no signal from CAN bus |
--- |
0.5 Sec 0.5 Sec |
2 DCY |
| P0601 |
Internal Control Module Memory Check Sum Error |
|
Calculate check sum |
|
0.5 Sec |
|
| P0602 |
Control Module Programming Error |
|
Message arriving from automatic transmission while ECU is calibrated for manual transmission-Message from automatic transmission |
--- |
0.5 Sec |
2 DCY |
| P0603 |
Internal Control Module Memory Check Sum Error |
|
Write and read back value is not correct |
--- |
200 mS |
yes; immediate |
| P0604 |
Internal Control Module Random Access Memory (RAM) Error |
|
Write ability check |
|
0.5 Sec |
|
| P0605 |
Internal Control Module Read Only Memory (ROM) Error |
|
Wrong check sum |
|
0.5 Sec |
|
| P0606 |
Internal Control Module Memory Check Sum Error |
|
Short to Battery +, > 4.88 V Short to Ground, 0.14 V |
--- |
2 Sec |
|
| P0638 |
Throttle Actuator Control Range/Performance |
|
OPEN to > ref. Point (+) 12%- t> 0.14 seconds Then CLOSED to ref. point (+) 3% t > 0.56 Sec Closed to 1% t > 0.3 Sec then OPEN to ref. (-) 1.5% t > 0.56 Sec Voltage ranges- sensor1: 0.21 - 0.87 V sensor 2: 4.14 - 4.84 V |
Ignition-ON Engine speed-0 Rpm Intake air temperature-> 5°C Vehicle speed-0 Mph ECT-> 5°C Ignition-ON Engine speed-0 Rpm Intake air temperature-> 5°C Vehicle speed-0 Mph ECT-> 5°C Ignition-ON Engine speed-0 Rpm Intake air temperature-> 5°C Vehicle speed-0 Mph ECT-> 5°C |
5 Sec |
|
| P0685 |
ECM/PCM Power Relay Control CircuitOpen |
|
Open circuit-Control voltage 0.61 Volts |
Sense circuit voltage-3.0 Volts |
0.5 Sec |
|
| P0686 |
ECM/PCM Power Relay Control Circuit Low |
|
Short to ground-Control voltage 0.51 Volts |
Sense circuit voltage- > 5.5 V |
0.5 Sec |
|
| P0687 |
ECM/PCM Power Relay Control Circuit High |
|
Short to battery positive-Control voltage >4.0 Volts |
Sense circuit voltage- 3.0 V |
0.5 Sec |
|
| P0688 |
ECM/PCM Power Relay Sense Circuit Open |
|
Voltage too low-3.0 Volts |
|
2 Sec |
|