Diagnostic Mode 01: Obtain data

Diagnostic Mode 01 is used to display and monitor all emissions related measured values.

Test requirement 

Procedure 

NOTE:
  • More than one "PID" may be selected and monitored.

The current values of the component or system that is being monitored will be displayed on the scan tool screen.

PID Description 
01: Number of malfunctions in Mode 3/MIL, Status/Readiness status
03: Fuel System Status
04: Calculated load value
05: Coolant temperature
06: Oxygen sensor integrator Bank 1/Bank 3
07: Oxygen sensor adaptation value Bank 1/Bank 3
08: Oxygen sensor integrator Bank 2/Bank 4
09: Oxygen sensor adaptation value Bank 2/Bank 4
11: Intake manifold pressure
12: Engine speed
13: Vehicle speed
14: Ignition angle cylinder 1
15: Intake air temperature
16: Air mass
17: Throttle valve position 1 absolute
18: Secondary air injection
19: Location of oxygen sensor LSF
20: LSF sensor voltage Bank 1 Sensor 1, Oxygen sensor integrator Bank 1
21: LSF sensor voltage Bank 1 Sensor 2
22: LSF sensor voltage Bank 1 Sensor 3
24: LSF sensor voltage Bank 2 Sensor 1, Oxygen sensor integrator Bank 2
25: LSF sensor voltage Bank 2 Sensor 2
26: LSF sensor voltage Bank 2 Sensor 3
28: OBD requirements
31: Time since engine start
32: Supported definition PIDs 33 - 64
33: Distance driven with MIL ON
35: Fuel pressure (rail pressure)
44: EGR activation
45: EGR error
46: Tank ventilation valve activation
48: No. of WUCs after erasing DTC memory
49: Distance driven after erasing DTD memory
51: Ambient pressure
52: Oxygen sensor actual value Bank 1 - Sensor 1, Oxygen sensor monitoring pump current Bank 1 - Sensor 1
56: Oxygen sensor actual value Bank 2 - Sensor 1, Oxygen sensor monitoring pump current Bank 2 - Sensor 1
58: Oxygen sensor actual value Bank 4 - Sensor 1, Oxygen sensor monitoring pump current Bank 4 - Sensor 1
60: Catalytic converter temperature Bank 1 Sensor 1
61: Catalytic converter temperature Bank 2 Sensor 1
64: Supported definition PIDs 65 - 96
65: Monitor status in this driving cycle
66: Control modules system voltage
67: Absolute load value
68: Oxygen sensor specified value
69: Relative throttle valve position
70: Ambient temperature
71: Absolute throttle valve position 2
73: Absolute accelerator pedal position 1
74: Absolute accelerator pedal position 2
76: Throttle valve specified position
86: Offset oxygen sensor control behind cat. Bank 1/Bank 3
88: Offset oxygen sensor control behind cat. Bank 2/Bank 4