Home >> Audi >> 2008 >> A4 Base, 2D Convertible >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating & Air Conditioning (On Board Diagnostic) >> 01 On Board Diagnostic (OBD) >> Diagnostic Trouble Code (DTC) Memory, checking (function 02) >> DTC table from DTC code "01044"
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC table from DTC code "01044"

Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01044 Control module incorrectly coded    
   
  • Instrument Cluster Control Module J285 not coded in specified manner
  • Malfunction on CAN-Bus comfort system
  • Operating and display unit, Climatronic Control Module J255 not coded according to specifications.
  • Check coding transmitted to operating and display module, Climatronic Control Module J255 (Reading measuring value block, display group "019") → Read Measuring Value Block (function 08) 
  • Check coding of Instrument Cluster Control Module J285 and code as specified if necessary Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • check DTC memories of all control units connected to CAN-Bus comfort system and locate and eliminate the CAN-Bus system faults displayed "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Check coding of operating and display module, Climatronic Control Module J255 → Climatronic Control Module J255, coding (function 07)  (coding for specific equipment).
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01087 Basic setting not performed    
   
  • During the "Basic setting" function a fault has occurred or the ignition was switched off and the operating and display module, Climatronic Control Module J255 was not able to complete the function.
  • Basic setting not performed following replacement of operating and display module, Climatronic Control Module J255.
  • Basic setting performed with a non-coded or incorrectly coded operating and display module, Climatronic Control Module J255
  • Perform basic setting of operating and display module, Climatronic Control Module J255 → Basic Setting (function 04) .
  • Check coding transmitted via the CAN-Bus comfort system to the operating and display module, Climatronic Control Module J255 (reading measuring value block, display group "019") → Read Measuring Value Block (function 08)  and then perform basic setting of operating and display module, Climatronic Control Module J255 → Basic Setting (function 04) .
NOTE:
  • The operating and display module, Climatronic Control Module J255 switches automatically to "ECON" mode if basic setting was not performed after installing a new operating and display module, Climatronic Control Module J255.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01171 Front Passengers Heated Seat Temperature Sensor G60    
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Open circuit in Front Passengers Seat Heating Element or in wiring between Front Passengers Heated Seat Temperature Sensor G60 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate open circuit
  • Check Front Passengers Heated Seat Temperature Sensor G60 and corresponding wiring → Heated seats, testing 
01172 Drivers Heated Seat Temperature Sensor G59    
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Open circuit in Drivers Seat Heating Element or in wiring between Drivers Heated Seat Temperature Sensor G59 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate open circuit
  • Check Drivers Heated Seat Temperature Sensor G59 and corresponding wiring → Heated seats, testing 
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01206 Ignition switched off time period signal    
 
  • Incorrect signal/SP
  • After connection of Battery A, Instrument Cluster Control Module J285 effected reset and was therefore not able to transmit a time signal
  • Start engine and allow to run for 30 seconds
  • Switch off engine
  • Switch on ignition
  • Check and erase DTC memory of operating and display module, Climatronic Control Module J255
   
  • Malfunction in Instrument Cluster Control Module J285
  • Check DTC memory of Instrument Cluster Control Module J285 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
NOTE:
  • If "ignition off time period signal" is not detected by the operating and display module, Climatronic Control Module J255 when the ignition is switched on (transmitted by Instrument Cluster Control Module J285 via CAN-Bus comfort system), the operating and display module, Climatronic Control Module J255 assumes a standing time of more than 4 hours and the engine temperature is taken to be the same as the ambient temperature. In heating mode, this can lead to delayed start-up of the Fresh Air Blower V2 despite the engine being warm. The Outside Air Temperature Display G106 in the instrument cluster may also display incorrect ambient temperature values.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01229 A/C Humidity Sensor G260    
 
  • Open circuit/short to positive/SP
  • Incorrect version of operating and display module, Climatronic Control Module J255.
  • Check part number and index of operating and display module, Climatronic Control Module J255
 
  • Open circuit/short to positive/SP
  • Short to Ground (GND)/SP
  • Short circuit, open circuit in wiring or incorrectly assigned connectors between A/C Humidity Sensor G260 and operating and display module, Climatronic Control Module J255
  • Open circuit in power supply or Ground (GND) connection to A/C Humidity Sensor G260
  • A/C Humidity Sensor G260 defective
  • Use wiring diagram to locate and eliminate short (to Ground (GND) or positive), open circuit in wiring or incorrectly assigned connectors between A/C Humidity Sensor G260 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate open circuit.
  • Replace A/C Humidity Sensor G260
NOTE:
  • The installation of an A/C Humidity Sensor G260 is not scheduled at present (date of introduction not yet finalized). This malfunction is displayed if a vehicle with no A/C Humidity Sensor G260 has been installed with an operating and display module, Climatronic Control Module J255 for vehicles with A/C Humidity Sensor G260 (not provided at present, date of introduction not yet finalized).
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01230 Left Footwell Vent Temperature Sensor G261    
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Short circuit or open circuit in wiring between Left Footwell Vent Temperature Sensor G261 and operating and display module, Climatronic Control Module J255
  • Left Footwell Vent Temperature Sensor G261 defective
01231 Right Footwell Vent Temperature Sensor G262    
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Short circuit or open circuit in wiring between Right Footwell Vent Temperature Sensor G262 and operating and display module, Climatronic Control Module J255
  • Right Footwell Vent Temperature Sensor G262 defective
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01232 A/C Compressor Regulator Valve N280    
 
  • Short to Ground (GND)/SP
  • Short to positive/SP
  • Open circuit/SP
  • Short circuit or open circuit in wiring between A/C Compressor Regulator Valve N280 and operating and display module, Climatronic Control Module J255
  • Open circuit in Ground (GND) connection to A/C Compressor Regulator Valve N280
  • Use wiring diagram to locate and eliminate short circuit or open circuit in wiring
   
  • A/C Compressor Regulator Valve N280 defective
NOTE:
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01272 Central Air Flap Motor V70    
 
  • Blocked or no voltage/SP
  • Short circuit, open circuit in wiring or wiring malfunction between Central Air Flap Motor V70 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction
   
  • Central flap stiff
  • Check freedom of movement of central flap
   
  • Central Air Flap Motor V70 defective
NOTE:
  • In the case of an operating and display module, Climatronic Control Module J255 up to hardware/software version "0203", the type of malfunction "Short to Ground (GND)" or "Open circuit/short to positive" may also be displayed for this control motor. The malfunction with these operating and display modules, Climatronic Control Module J255 is the same as for the malfunction "Blocked or no voltage".
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01273 Fresh Air Blower V2    
 
  • Blocked or no voltage/SP
  • Duty cycle transmitted 55 to 64 %
  • Fresh Air Blower V2 blocked, e.g. by obstruction
  • Fresh Air Blower V2 defective
  • Remove Fresh Air Blower V2 and check for obstruction
  • Replace Fresh Air Blower V2
 
  • Defective
  • Duty cycle transmitted 15 to 24% or 65 to 74%
  • Fresh Air Blower Control Module J126 in Fresh Air Blower V2 defective
  • Replace Fresh Air Blower V2
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Short circuit or open circuit in wiring between Fresh Air Blower V2 (or to Fresh Air Blower Control Module J126) and operating and display module, Climatronic Control Module J255
  • Open circuit in power supply or Ground (GND) connection to Fresh Air Blower V2 (or to Fresh Air Blower Control Module J126).
  • Use wiring diagram to locate and eliminate short circuit or open circuit in wiring
  • Use wiring diagram to locate and eliminate open circuit
Continued in next table    
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01273 (continued)    
 
  • Signal outside tolerance/SP
  • Duty cycle transmitted 75 to 84%
  • Loose contact (short circuit, open circuit in wiring) or contact resistance between Fresh Air Blower V2 (or to Fresh Air Blower Control Module J126) and operating and display module, Climatronic Control Module J255
  • Problems with activation of Fresh Air Blower V2 by operating and display module, Climatronic Control Module J255
  • Fresh Air Blower V2 defective
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction.
  • Replace operating and display module, Climatronic Control Module J255.
  • Replace Fresh Air Blower V2
 
  • Voltage supply too low/SP
  • Duty cycle transmitted 35 to 44%
  • Voltage dips in vehicle electrical system to values below 9.5 V
  • Open circuit or contact resistance in power supply to Fresh Air Blower V2
  • Check Generator (GEN) C, Voltage Regulator (VR) C1, Battery A and corresponding wiring
  • Use wiring diagram to check wiring to Fresh Air Blower Control Module J126
 
  • Voltage supply too high/SP
  • Duty cycle transmitted 25 to 34%
  • Voltage in vehicle electrical system has exceeded 15 V
  • Check Generator (GEN) C and Voltage Regulator (VR) C1
NOTE:
  • The Fresh Air Blower V2 contains the Fresh Air Blower Control Module J126 as an integral component which cannot be replaced separately.
  • The status of the Fresh Air Blower is displayed in the measuring value block (display group "018"). By way of this status display, the operating and display module, Climatronic Control Module J255 is informed by the Fresh Air Blower Control Module J126 of any malfunctions at the Fresh Air Blower V2 → Read Measuring Value Block (function 08) .
  • The malfunction "Voltage supply too high/SP" may also be displayed if an unsuitable charging unit is used for charging the Battery A.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01274 Air Flow Flap Motor V71    
 
  • Blocked or no voltage/SP
  • Short circuit, open circuit in wiring or wiring malfunction between Air Flow Flap Motor V71 and operating and display module, Climatronic Control Module J255
  • Fresh-air or air flow flap stiff (left-hand drive vehicles)
  • Air Flow Flap Motor V71 defective
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction
  • Check freedom of movement of fresh-air and air flow flap
   
  • Operating and display unit, Climatronic Control Module J255 incorrectly coded.
  • Comfort System Central Control Module J393 incorrectly coded.
  • Check coding of operating and display module, Climatronic Control Module J255 and code transmitted to operating and display module, Climatronic Control Module J255 (Reading measuring value block, display group "019"), → Read Measuring Value Block (function 08) 
  • Check coding of Comfort System Central Control Module J393 and code control unit as specified if necessary "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
NOTE:
  • This control motor is used to activate the air flow/fresh-air flap.
  • In the case of operating and display modules, Climatronic Control Module J255 up to hardware/software version "0203", the type of malfunction "Short to Ground (GND)" or "Open circuit/short to positive" may also be displayed for this control motor. The malfunction with these operating and display modules, Climatronic Control Module J255 is the same as for the malfunction "Blocked or no voltage".
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01312 Drive train CAN-Bus    
  Check DTC memory
  • The Instrument Cluster Control Module J285 cannot output the required data because of a malfunction and sets a malfunction.
  • The Instrument Cluster Control Module J285 cannot output the required data because of a malfunction in an upstream component and sets a malfunction.
  • A control unit linked to the drive CAN-Bus system is not supplying the required data or there is a malfunction in the drive CAN-Bus system.
  • Check DTC memory of Instrument Cluster Control Module J285 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Determine and eliminate the causes of all DTCs in the DTC memory of the Instrument Cluster Control Module J285.
  • check DTC memories of all control units connected to drive CAN-Bus system and locate and eliminate the drive CAN-Bus system faults displayed "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
NOTE:
  • If, for example, the engine control module does not supply any information on the current engine RPM (via the drive CAN-Bus system), the Instrument Cluster Control Module J285 cannot incorporate this information into the data for the CAN-Bus comfort system and this malfunction entry is made in the DTC memory of the operating and display module, Climatronic Control Module J255.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01317 Instrument Cluster Control Module J285    
 
  • Check DTC memory
  • The Instrument Cluster Control Module J285 cannot output the required data because of a malfunction and sets a malfunction.
  • The Instrument Cluster Control Module J285 cannot output the required data because of a malfunction in an upstream component and sets a malfunction.
  • Check DTC memory of Instrument Cluster Control Module J285 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Determine and eliminate the causes of all DTCs in the DTC memory of the Instrument Cluster Control Module J285.
 
  • No communication/SP
  • Open circuit in both signal wires (CAN-Bus system) between Instrument Cluster Control Module J285 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate open circuit or loose contact at both signal wires (CAN-Bus system) between Instrument Cluster Control Module J285 and operating and display module, Climatronic Control Module J255
  • Check CAN-Bus comfort system → CAN-Bus comfort system, checking .
Continued in next table    
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01317 (continued)    
 
  • No communication/SP
  • Malfunction affecting data output in Instrument Cluster Control Module J285 or in a component connected to it
  • Check DTC memory of Instrument Cluster Control Module J285 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
   
  • No data transmitted by Instrument Cluster Control Module J285.
  • The operating and display module, Climatronic Control Module J255 cannot read the data transmitted by the Instrument Cluster Control Module J285.
   
  • Interruption of voltage to Instrument Cluster Control Module J285 with ignition switched on
  • check and erase DTC memories of all control units connected to the various CAN-Bus systems "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
Continued in next table    
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01317 (continued)    
 
  • No communication/SP
  • The Instrument Cluster Control Module J285 transmits the information correctly, however this malfunction is entered in the operating and display module, Climatronic Control Module J255 (up to software version "XX14") because of a specific optional extra.
  • Check display in measuring value blocks "125" and "126" and observe the notes on display zone "1" in measuring value block "125".
NOTE:
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01322 Multi-function Unit Control Module J501    
 
  • Check DTC memory
  • No communication (time out)/SP
  • Refer to DTC code "00457" Vehicle Electrical System Control Module J519
  • Check DTC memory of Vehicle Electrical System Control Module J519 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Determine and eliminate the causes of all DTCs in the DTC memory of the Vehicle Electrical System Control Module J519.
NOTE:
  • With certain operating and display modules, Climatronic Control Module J255, the Multi-function Unit Control Module J501 was stored as malfunction location in the software instead of the Vehicle Electrical System Control Module J519.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01326 Multi-function Steering Wheel Control Module J453    
 
  • Check DTC memory
  • No communication (time out)/SP
  • Refer to DTC code "00466" Steering Column Electronic Systems Control Module J527
  • Check DTC memory of Steering Column Electronic Systems Control Module J527 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Determine and eliminate the causes of all DTCs in the DTC memory of the Steering Column Electronic Systems Control Module J527.
NOTE:
  • With certain operating and display modules, Climatronic Control Module J255, the Multi-function Steering Wheel Control Module J453 was stored as malfunction location in the software instead of the Steering Column Electronic Systems Control Module J527.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01330 Comfort System Central Control Module J393    
 
  • Check DTC memory
  • The Comfort System Central Control Module J393 cannot output the required data because of a malfunction and sets a malfunction.
  • The Comfort System Central Control Module J393 cannot output the required data because of a malfunction in an upstream component and sets a malfunction.
  • Check DTC memory of Comfort System Central Control Module J393 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Determine and eliminate the causes of all DTCs in the DTC memory of the Comfort System Central Control Module J393.
 
  • No communication (time out)/SP
  • Open circuit in both signal wires (CAN-Bus system) between Comfort System Central Control Module J393 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate open circuit or loose contact at both signal wires (CAN-Bus system) between Comfort System Central Control Module J393 and operating and display module, Climatronic Control Module J255
  • Check CAN-Bus comfort system → CAN-Bus comfort system, checking .
Continued in next table    
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01330 (continued)    
 
  • No communication (time out)/SP
  • Malfunction affecting data output in Comfort System Central Control Module J393 or in a component connected to it
  • Check DTC memory of Comfort System Central Control Module J393 "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
   
  • No data transmitted by Comfort System Central Control Module J393
  • The operating and display module, Climatronic Control Module J255 cannot read the data transmitted by the Comfort System Central Control Module J393.
   
  • Interruption of voltage to Comfort System Central Control Module J393 with ignition switched on
  • check and erase DTC memories of all control units connected to CAN-Bus comfort system "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
NOTE:
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01336 Group CAN-Bus comfort system    
  Defect (Bus Off)
  • Open circuit or short to Ground (GND)/positive in CAN-Bus comfort system signal wire
  • Short circuit between CAN-Bus signal wires
  • Use wiring diagram to locate and eliminate short circuit (to Ground (GND), positive or between signal wires) or open circuit in CAN-Bus comfort system wiring
   
  • CAN-Bus signal wires interchanged
  • Use wiring diagram to check signal wires of CAN-Bus comfort system.
   
  • Destruction by one of the control units connected to the CAN-Bus comfort system of data transmitted.
Continued in next table    
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01336 (continued)    
  Defect (Bus Off)
  • Control unit not designed for CAN-Bus connected to CAN-Bus comfort system
  • Check part number of all control units connected to CAN-Bus system "Guided fault-finding" function of Diagnostic Operation System VAS 5051, "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  In one-wire operation
  • Open circuit or short to Ground (GND)/positive in CAN-Bus comfort system signal wire
  • Use wiring diagram to locate and eliminate short circuit (to Ground (GND), positive or between signal wires) or open circuit in CAN-Bus comfort system wiring
   
  • Destruction by one of the control units connected to the CAN-Bus comfort system of data transmitted on one of the two signal wires.
Continued in next table    
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01336 (continued)    
 
  • No messages (time out for several control modules)
  • Open circuit in wiring, e.g. at junction of CAN-Bus signal wires
  • Open circuit in power supply to one or more control unit(s) connected to CAN-Bus comfort system
  • Use wiring diagram to locate and eliminate open circuit in wiring in CAN-Bus comfort system
  • Use wiring diagram to locate and eliminate open circuit in power supply to one or more control unit(s) connected to CAN-Bus comfort system., "Guided Fault-Finding" Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
NOTE:
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01592 Air Quality Sensor G238    
 
  • Open circuit/short to positive/SP
  • Short to Ground (GND)/SP
  • Short circuit, open circuit in wiring or incorrectly assigned connectors between Air Quality Sensor G238 and operating and display module, Climatronic Control Module J255
  • Incorrect version of operating and display module, Climatronic Control Module J255.
  • Use wiring diagram to locate and eliminate short (to Ground (GND) or positive), open circuit in wiring or incorrectly assigned connectors between Air Quality Sensor G238 and operating and display module, Climatronic Control Module J255
  • Check part number and index of operating and display module, Climatronic Control Module J255
 
  • Defective
  • Open circuit in power supply or Ground (GND) connection to Air Quality Sensor G238
  • Air Quality Sensor G238 defective
  • Locate and eliminate open circuit in power supply or Ground (GND) connection to Air Quality Sensor G238
  • Replace Air Quality Sensor G238
 
  • Electr. fault in circuit/SP
  • Air Quality Sensor G238 defective
  • Replace Air Quality Sensor G238
NOTE:
  • Under certain circumstances, radio wave interference (e.g. amateur or police radio systems) may cause sporadic malfunction entries for the Air Quality Sensor G238. this malfunction entry can be erased if applicable as the function of the operating and display module, Climatronic Control Module J255 is not affected.
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01593 Heated Windshield Z2    
 
  • Short to positive/SP
  • Operating and display unit, Climatronic Control Module J255 not coded according to specifications.
   
  • Short circuit or open circuit in wiring between Heated Windshield Control Module J505 and operating and display module, Climatronic Control Module J255
  • Open circuit in power supply or Ground (GND) connection to Heated Windshield Control Module J505
   
  • Heated Windshield Control Module J505 defective
  • Replace Heated Windshield Control Module J505
NOTE:
  • If, on a vehicle with no Heated Windshield Z2, the operating and display module, Climatronic Control Module J255 is coded for a vehicle with the Heated Windshield Z2 optional extra, the malfunction "Open circuit/short to Ground (GND)" or "Short to positive" is entered (depending on software version in operating and display module, Climatronic Control Module J255).
  • In the case of an operating and display module, Climatronic Control Module J255 up to hardware/software version "0203", the type of malfunction displayed for the Heated Windshield Z2 may also be "Open circuit/short to Ground (GND)". The malfunction with these operating and display modules, Climatronic Control Module J255 is the same as for the malfunction "Short to positive".
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01794 Control module incorrect Vehicle Identification Number (VIN)    
   
  • VIN stored in operating and display module, Climatronic Control Module J255 different to that transmitted by CAN-Bus comfort system
  • Check transmitted and actual VIN and compare to VIN stored in operating and display module, Climatronic Control Module J255 (Reading measuring value block" function, display group "081") and read out measuring value block of Instrument Cluster Control Module J285 Vehicle Diagnosis, Testing Info. System VAS5051B or Vehicle Diagnosis Service Syst. VAS5052
  • Use the "Adaptation" function to erase the VIN stored in the operating and display module, Climatronic Control Module J255 → Climatronic Control Module J255, Adaptation (function 10) .
NOTE:
  • New replacement operating and display modules, Climatronic Control Module J255 are supplied without VIN coding. The first time the ignition is switched on following installation, the VIN transmitted via the CAN-Bus comfort system is read into the operating and display module, Climatronic Control Module J255 (as of hardware/software version "0711") and stored (anti-theft protection).
  • The VIN stored in the operating and display module, Climatronic Control Module J255 is indicated in display group "081" (Reading measuring value block).
  • If an operating and display module, Climatronic Control Module J255 (as of hardware/software version "0711") is installed in a different vehicle (e.g. swapped over), the transmitted and stored VINs no longer coincide and the malfunction "Control module incorrect Vehicle Identification Number (VIN)" is stored in the operating and display module, Climatronic Control Module J255. Entering the PIN in the "Adaptation" function erases the VIN stored in the operating and display module, Climatronic Control Module J255 → Climatronic Control Module J255, Adaptation (function 10) .
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01809 Left Temperature Flap Motor V158    
 
  • Blocked or no voltage/SP
  • Short circuit, open circuit in wiring or wiring malfunction between Left Temperature Flap Motor V158 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction
   
  • Left temperature flap stiff
  • Left Temperature Flap Motor V158 defective
NOTE:
  • In the case of an operating and display module, Climatronic Control Module J255 up to hardware/software version "0203", the type of malfunction "Short to Ground (GND)" or "Open circuit/short to positive" may also be displayed for this control motor. The malfunction with these operating and display modules, Climatronic Control Module J255 is the same as for the malfunction "Blocked or no voltage".
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01810 Right Temperature Flap Motor V159    
 
  • Blocked or no voltage/SP
  • Short circuit, open circuit in wiring or wiring malfunction between Right Temperature Flap Motor V159 and operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction
   
  • Right temperature flap stiff
  • Right Temperature Flap Motor V159 defective
NOTE:
  • In the case of an operating and display module, Climatronic Control Module J255 up to hardware/software version "0203", the type of malfunction "Short to Ground (GND)" or "Open circuit/short to positive" may also be displayed for this control motor. The malfunction with these operating and display modules, Climatronic Control Module J255 is the same as for the malfunction "Blocked or no voltage".
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01841 Left Temperature Flap Potentiometer/Actuator G220 in Left Temperature Flap Motor V158    
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Short circuit, open circuit in wiring or wiring malfunction between Left Temperature Flap Potentiometer/Actuator G220 and operating and display module, Climatronic Control Module J255
  • Left Temperature Flap Potentiometer/Actuator G220 in Left Temperature Flap Motor V158 defective
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction
  • Replace Left Temperature Flap Motor V158
 
  • Adaptation limit exceeded
  • Temperature flap stiff
  • Left Temperature Flap Potentiometer/Actuator G220 in Left Temperature Flap Motor V158 defective
  • Check freedom of movement of temperature flap
  • Replace Left Temperature Flap Motor V158
NOTE:
  • The DTC "Adaptation limit exceeded" is only detected during basic setting. If this malfunction occurs, a substitute value is stored as adaptation value (adaptation value for this potentiometer) and displayed in the corresponding measuring value block.
  • If the malfunction "Adaptation limit exceeded" is displayed, check whether flap reaches both end stops and that there is no excessive play in the operating levers (wear).
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
01842 Right Temperature Flap Potentiometer/Actuator G221 in Right Temperature Flap Motor V159    
 
  • Short to Ground (GND)/SP
  • Open circuit/short to positive/SP
  • Short circuit, open circuit in wiring or wiring malfunction between Right Temperature Flap Potentiometer/Actuator G221 and operating and display module, Climatronic Control Module J255
  • Right Temperature Flap Potentiometer/Actuator G221 in Right Temperature Flap Motor V159 defective
  • Use wiring diagram to locate and eliminate short circuit, open circuit in wiring or wiring malfunction
  • Replace Right Temperature Flap Motor V159
  Adaptation limit exceeded
  • Temperature flap stiff
  • Right Temperature Flap Potentiometer/Actuator G221 in Right Temperature Flap Motor V159 defective
  • Check freedom of movement of temperature flap
  • Replace Right Temperature Flap Motor V159
NOTE:
  • The DTC "Adaptation limit exceeded" is only detected during basic setting. If this malfunction occurs, a substitute value is stored as adaptation value (adaptation value for this potentiometer) and displayed in the corresponding measuring value block.
  • If the malfunction "Adaptation limit exceeded" is displayed, check whether flap reaches both end stops and that there is no excessive play in the operating levers (wear).
Display on Diagnostic Operation System VAS 5051A and print output Possible cause Corrective action
65535 Control unit defective/SP    
   
  • Open circuit in wiring to operating and display module, Climatronic Control Module J255 (terminal "30", "75" or terminal "31")
  • Loose contact or contact resistance in wiring to operating and display module, Climatronic Control Module J255
  • Use wiring diagram to locate and eliminate fault in wiring
  • Check buttons of operating and display module, Climatronic Control Module J255 for dirt and clean if necessary.
   
  • One or more buttons of operating and display module, Climatronic Control Module J255 constantly pressed (button sticking)
  • Replace operating and display module, Climatronic Control Module J255
   
  • Malfunction in program sequence of operating and display module, Climatronic Control Module J255
  • Operating and display unit, Climatronic Control Module J255 defective
  • Replace operating and display module, Climatronic Control Module J255