  1. POWER WINDOW OPERATION IN FAIL-SAFE MODE 
    1. The power window control system prohibits the following power window operations when the pulse sensor for the jam protection function is malfunctioning and the window position or the learned value is abnormal.

      HINT: 

      If the pulse sensor built into the power window regulator motor malfunctions, the power window control system enters fail-safe mode.

      MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

      Power Window Operation Condition
      Power switch on (IG) Power switch off
      (Key-off operation permitted)
      Power switch off
      (Key-off operation prohibited)
      Manual up (Driver door window) X X -
      Manual down (Driver door window) X -
      Auto up (Driver door window)
      (hold switch at auto up position)
      ◦* X -
      Auto up (Driver door window) X X -
      Auto down (Driver door window) X X -
      Manual up (Remote switch operation) X X -
      Manual down (Remote switch operation) X X -
      Auto up (Remote switch operation)
      (hold switch at auto up position)
      X X -
      Auto up (Remote switch operation) X X -
      Auto down (Remote switch operation) X X -

      HINT: 

      • ◦: Operates
      • X: Operation prohibited
      • *: Operates in manual mode without jam protection
      POWER WINDOW REGULATOR SWITCH ASSEMBLY AND REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY (FOR LH AND RH DOORS)

      Power Window Operation Condition
      Power switch on (IG) Power switch off
      (Key-off operation permitted)
      Power switch off
      (Key-off operation prohibited)
      Manual up X X -
      Manual down X -
      Auto up
      (hold switch at auto up position)
      ◦* X -
      Auto up X X -
      Auto down X X -

      HINT: 

      • ◦: Operates
      • X: Operation prohibited
      • *: Operates in manual mode without jam protection
      KEY-LINKED AND WIRELESS TRANSMITTER-LINKED OPERATION*

      Power Window Operation Condition
      Power switch on (IG) Power switch off
      (Key-off operation permitted)
      Power switch off
      (Key-off operation prohibited)
      Key-linked open and close* - X X
      Wireless transmitter-linked open* - X X
      • *: This function is set through the customize function, as it is off by default.

      HINT: 

      X: Operation prohibited

      1. Fail-safe deactivation condition
        • When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully opened position. As a result, the auto up and down functions will return.
    2. Initialization failure

      HINT: 

      During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM, the power window control system prohibits operation as follows:

      MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

      Power Window Operation Condition
      Power switch on (IG) Power switch off
      (Key-off operation permitted)
      Power switch off
      (Key-off operation prohibited)
      Manual up (Driver door window) X X -
      Manual down (Driver door window) X -
      Auto up (Driver door window)
      (hold switch at auto up position)
      ◦* X -
      Auto up (Driver door window) X X -
      Auto down (Driver door window) X X -
      up (Remote switch operation) X X -
      Manual down (Remote switch operation) X X -
      Auto up (Remote switch operation)
      (hold switch at auto up position)
      X X -
      Auto up (Remote switch operation) X X -
      Auto down (Remote switch operation) X X -

      HINT: 

      • ◦: Operates
      • X: Operation prohibited
      • *: Operates in manual mode without jam protection
      POWER WINDOW REGULATOR SWITCH ASSEMBLY AND REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY (FOR LH AND RH DOORS)

      Power Window Operation Condition
      Power switch on (IG) Power switch off
      (Key-off operation permitted)
      Power switch off
      (Key-off operation prohibited)
      Manual up X X -
      Manual down X -
      Auto up
      (hold switch at auto up position)
      ◦* X -
      Auto up X X -
      Auto down X X -

      HINT: 

      • ◦: Operates
      • X: Operation prohibited
      • *: Operates in manual mode without jam protection
      KEY-LINKED AND WIRELESS TRANSMITTER-LINKED OPERATION*

      Power Window Operation Condition
      Power switch on (IG) Power switch off
      (Key-off operation permitted)
      Power switch off
      (Key-off operation prohibited)
      Key-linked open and close* - X X
      Wireless transmitter-linked open* - X X
      • *: This function is set through the customize function, as it is off by default.

      HINT: 

      X: Operation prohibited

    3. LIN communication failure

      HINT: 

      If the LIN communication line malfunctions (communication stop), the power window control system prohibits operation as follows:

      MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

      Power Window Operation Condition
      Power switch on (IG)
      Manual up ◦*
      Manual down
      Auto up (hold switch at auto up position) -
      Auto up -
      Auto down -

      HINT: 

      • ◦: Operates
      • *: Jam protection can operate.
      • Remote up and down function does not operate.
      POWER WINDOW REGULATOR SWITCH ASSEMBLY AND REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY (FOR LH AND RH DOORS)

      Power Window Operation Condition
      Power switch on (IG)
      Manual up ◦*
      Manual down
      Auto up (hold switch at auto up position) ◦*
      Auto up ◦*
      Auto down

      HINT: 

      • ◦: Operates
      • *: Jam protection can operate.
    4. LIN communication failure and pulse sensor failure

      HINT: 

      If the LIN communication line malfunctions (communication stop) and the pulse sensor for the jam protection function is malfunctioning, the power window control system prohibits operation as follows:

      MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

      Power Window Operation Condition
      Always
      Manual up X
      Manual down X
      Auto up (hold switch at auto up position) X
      Auto up X
      Auto down X

      HINT: 

      • X: Operation prohibited
      • Driver door window: When the jam protection function does not operate due to the LIN communication failure, the manual up and auto up functions will not operate.
      • Remote switch operation: Not operative during the LIN communication failure
      POWER WINDOW REGULATOR SWITCH ASSEMBLY AND REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY (FOR LH AND RH DOORS)

      Power Window Operation Condition
      Always
      Manual up X
      Manual down X
      Auto up (hold switch at auto up position) X
      Auto up X
      Auto down X

      HINT: 

      • X: Operation prohibited
    5. LIN communication failure and abnormal window position learned value or initialization failure

      HINT: 

      If the LIN communication line malfunctions (communication stop) and the window position or the learned value is abnormal, the power window control system prohibits operation as follows:

      MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

      Power Window Operation Condition
      Always
      Manual up ◦*
      Manual down
      Auto up (hold switch at auto up position) -
      Auto up -
      Auto down -

      HINT: 

      • ◦: Operates
      • *: Jam protection can operate and the window reverses upon reaching the fully closed position.
      • Remote switch operation: Operation is not possible during the LIN communication failure.
      POWER WINDOW REGULATOR SWITCH ASSEMBLY AND REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY (FOR LH AND RH DOORS)

      Power Window Operation Condition
      Always
      Manual up ◦*
      Manual down
      Auto up (hold switch at auto up position) ◦*
      Auto up X
      Auto down X

      HINT: 

      • ◦: Operates
      • X: Operation prohibited
      • *: Jam protection can operate and the window reverses upon reaching the fully closed position.