Engine Control Module: Installing
Install in reverse order of removal.
-- After that, the ECM -- must be equipped with the metal retainer.
-- Clean threaded holes for shear bolts of locking compound residue. Cleaning can be performed with a thread cutter (tap).
-- Always use new shear bolts.
- Tightening Specifications E-box cover bolts: 3.5 Nm
Perform the following step after installing a new engine control module:
-- Activate the engine control module in the "Guided Functions " operating mode under "Replace engine control module " on the vehicle diagnosis and service system VAS5051B.