Distance Regulation Control Module - J428- / Distance Regulation Control Module 2 - J850- Retaining Plate, Removing and Installing: Installing
NOTE:
- Replace the quick release
- The stud bolts in the bracket are pre-set. If necessary, correct the setting.
- If the stud bolts were removed, then the clips on the distance regulation control module must be replaced. Refer to DISTANCE REGULATION CONTROL MODULE - J428- / DISTANCE REGULATION CONTROL MODULE 2 - J850- CLIP, REPLACING .
- Place the control module on a soft and clean surface.
- Measure the dimension -a- at all stud bolts using the Digital Caliper - VAS 6335- and correct if necessary.
- The dimension -a- = 43.3 mm.
- Position the retaining plate -2- onto the distance regulation control module -item 3-.
- Carefully press the new quick release -4- onto the stud bolt -2-.
- Turn the quick release clockwise onto the retaining plate to the stop.