Monitor-Id $A2 (162): Mis-Fire Cylinder 1 Data
-- Connect the scan tool.
-- Start the engine and run at idle.
-- Select "Mode 6: Check test the results of components that are not continuously monitored".
Select "Monitor-ID $A2 (162)".
-- Select the desired "Test-ID" or "Hex-ID".
-- Check specified values at idle.
| Test-ID | DTC | Component or System | Min./Max. Values | Additional Information |
|---|---|---|---|---|
| $0B (11) | P0301 | Cylinder 1 Data averaged during last 10 drive cycles. | 0 - 65535 (counts) | Refer to DTC P0301 in the DTC summary table. DTC TABLES P0301 |
| $0C (12) | P0301 | Cylinder 1 Data averaged during current drive cycle. | 0 - 65535 (counts) | Refer to DTC P0301 in the DTC summary table. DTC TABLES P0301 |
-- If any of components or systems fail to meet the specified values. Refer to Diagnostic "Mode 03: Interrogating Fault Memory" to check for stored DTC's or the corresponding diagnostic repair procedure DIAGNOSTIC MODE 03 - READ DTC MEMORY .
-- Switch the ignition OFF.