| P0530 A/C Refrigerant Pressure Sensor "A" Circuit |
P/T Sensor Pressure Sensor |
- Corresponding internal voltage > 3.36 V; < 0.38 V
- Corresponding internal resistance > 32 mΩ; > 320 kΩ
- Internal self check for pressure sensor = invalid [-]
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0531 A/C Refrigerant Pressure Sensor "A" Circuit Range/Performance |
P/T Sensor |
- Difference between refrigerant pressure sensor value and modeled pressure value exceeds valid range ≥ pressure threshold p(T) (calculated threshold as a function p(T) out of p/T sensor temperature sensor "A" value p(T) = 3 for T < 2° C; p(T) = (1/48*T + 71/24) for 2° C ≤ T ≤ 50° C; p(T) = 4 for T > 50° C;)
|
- LIN communication = active
- Refrigerant system time off (is equal to vehicle shutdown time without refrigerant system activity) ≥ 6
- Difference between refrigerant temperature and ambient temperature < 10 K
- Difference between refrigerant temperature and battery inlet coolant temperature < 10 K
- Concerning other ECUs:
- Battery inlet coolant sensor monitoring in BECM = no failures detected
- Battery coolant distribution valve monitoring in BECM = no failures detected
- Battery cooling monitoring in BECM = no failures detected
- Battery temperature sensor monitoring in BECM = no failures detected
- Ambient air temperature sensor monitoring in ECM
|
|
|
- Difference between maximum refrigerant pressure sensor value and minimum refrigerant pressure sensor value during the DCY < 0.5 bar
|
- A/C compressor speed ≥ 800 RPM
- For at least (cumulative) ≥ 30.0 s
- For activation:
- After ignition off (during HVAC keep alive-time)
|
|
- ADC conversion timeout > 0.0025 ms
|
- LIN communication = active [-]
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- ADC conversion functional = invalid [-]
|
- ASIC internal self check = invalid [-]
|
| P0533 A/C Refrigerant Pressure Sensor "A" Circuit High |
P/T Sensor Pressure Sensor |
- Pressure value above valid range received from sensor > 35 bar
|
- LIN communication = active [-]
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0534 A/C Refrigerant Charge Loss |
Refrigerant Circuit Low Pressure Monitoring |
- Refrigerant system pressure sensor value is below valid range < 2 bar
|
- Ambient air temperature ≥ 2° C
- Concerning other ECUs:
- Ambient air temperature sensor monitoring in BCM = no failures detected
|
|
|
| P0604 Internal Control Module Random Access Memory (RAM) Error |
HVAC Detects A Control Module Ram Error |
- Pattern read/write check = invalid [-]
|
|
|
|
| P0605 Internal Control Module Read Only Memory (ROM) Error |
HVAC Detects A Control Module ROM Error |
- Calculated checksum != stored ROM checksum [-]
|
|
|
|
| P062F Internal Control Module EEPROM Error |
HVAC Detects A Control Module EEPROM Error |
- Calculated EEPROM checksum != stored EEPROM checksum [-]
|
|
|
|
| P064F Unauthorized Software/Calibration Detected |
HVAC Detects If A Not Permitted HVAC Control Module Is Installed |
- Received OBD requirement code flag != expected flag [-]
|
|
|
|
| P0D69 A/C Compressor Motor Voltage Sensor "A" Performance |
Electric A/C Compressor Voltage Sensor A |
- A/C compressor voltage sensor value > 485.0 V
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- Difference between motor voltage sensor "A" and "B" value exceeds valid range > 10 (from motor voltage sensor "B" value) %
|
| P0D6A A/C Compressor Motor Voltage Sensor "A" Circuit High |
Electric A/C Compressor Voltage Sensor A |
- A/C compressor voltage sensor value > 492.0 V
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0D6B A/C Compressor Motor Voltage Sensor "A" Circuit Low |
Electric A/C Compressor Voltage Sensor A |
- A/C compressor voltage sensor value < 3.0 V
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0D6F A/C Compressor Motor Current High |
Electric A/C Compressor Current Sensor |
- A/C compressor current sensor value > 40.0 A
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0D71 A/C Compressor Control Module Internal Temperature Sensor Performance |
Electric A/C Compressor Temperature Sensor |
- Crosscheck between refrigerant temperature sensor value and A/C compressor control module temperature sensor value exceeds valid range > 15 K
|
- LIN communication = active
- Refrigerant system time off (is equal to vehicle shutdown time without refrigerant system activity) ≥ 6.0 h
|
|
|
| P0D72 A/C Compressor Control Module Internal Temperature Sensor Circuit High |
Electric A/C Compressor Temperature Sensor |
- A/C compressor temperature sensor value > 178° C
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0D73 A/C Compressor Control Module Internal Temperature Sensor Circuit Low |
Electric A/C Compressor Temperature Sensor |
- A/C compressor temperature sensor value < -39° C
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EA9 A/C Compressor Motor Voltage Sensor "B" Circuit Performance |
Electric A/C Compressor Voltage Sensor B |
- A/C compressor reference voltage sensor value > 485.0 V
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EAA A/C Compressor Motor Voltage Sensor "B" Circuit High |
Electric A/C Compressor Voltage Sensor B |
- A/C compressor reference voltage sensor value > 492.0 V
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EAB A/C Compressor Motor Voltage Sensor "B" Circuit Low |
Electric A/C Compressor Voltage Sensor B |
- A/C compressor reference voltage sensor value < 3.0 V
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EAE A/C Compressor Motor Current Sensor Range/Performance |
Electric A/C Compressor Current Sensor |
- A/C compressor current sensor value > 1.5 A
|
- LIN communication = active
- Vehicle high voltage system = active
- Requested A/C compressor speed (standstill mode) = 0 RPM
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- Difference between A/C compressor current sensor and model based A/C compressor current out of A/C compressor phases current sensor values exceeds valid range > 25%
|
- LIN communication = active
- Vehicle high voltage system = active
- A/C compressor speed. 2, 000 RPM
- A/C compressor speed < 6, 000 RPM
- A/C compressor current sensor > 1.0 A
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EB0 A/C Compressor Motor Current Sensor Circuit High |
Electric A/C Compressor Current Sensor |
- A/C compressor current state sensor value > 65.5 A
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EB2 A/C Compressor Motor Phase U Current Sensor Circuit High |
Electric A/C Compressor Phase Current Sensor U |
- A/C compressor motor phase U sensor current value > 39.2 A
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EB3 A/C Compressor Motor Phase U Current Sensor Circuit Low |
Electric A/C Compressor Phase Current Sensor U |
- A/C compressor motor phase U sensor current value < -39.2 A
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EB4 A/C Compressor Motor Phase U Current Sensor Range/Performance |
Electric A/C Compressor Phase Current Sensor U |
- A/C compressor motor phase V sensor current value exceeds valid range > 2.0 A; < -2.0 A
|
- LIN communication = active
- Vehicle high voltage system = active
- A/C compressor speed request ≥ 800 RPM
|
- 5 failure counts out of 5 samples 100.0 ms / sample on start up and on every rerun
|
|
- Difference between measured A/C compressor motor phase U sensor current and expected phase U current value exceeds valid range > 20 (from +8, 1 A) %
|
- LIN communication = active
- Vehicle high voltage system = active
- A/C compressor speed request ≥ 800 RPM
|
- 5 failure counts out of 5 samples 100.0 ms / sample on start up and on every rerun
|
|
- Difference between A/C compressor current sensor and model based A/C compressor current out of A/C compressor phases current sensor values exceeds valid range > 25%
|
- LIN communication = active
- Vehicle high voltage system = active
- A/C compressor speed. 2, 000 RPM
- A/C compressor speed < 6, 000 RPM
- A/C compressor current sensor > 1.0 A
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- A/C compressor motor phase U sensor current value > 33.7
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- A/C compressor motor phase U sensor current value < -33.7
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EB5 A/C Compressor Motor Phase V Current Sensor Circuit High |
Electric A/C Compressor Phase Current Sensor V |
- A/C compressor motor phase V sensor current value > 39.2 A
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EB6 A/C Compressor Motor Phase V Current Sensor Circuit Low |
Electric A/C Compressor Phase Current Sensor V |
- A/C compressor motor phase V sensor current value < -39.2 A
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100 ms / sample continuous
|
|
| P0EB7 A/C Compressor Motor Phase V Current Sensor Range/Performance |
Electric A/C Compressor Phase Current Sensor V |
- A/C compressor motor phase V sensor current value > 33.7
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- A/C compressor motor phase V sensor current value < -33.7
|
- A/C compressor motor phase V sensor current value exceeds valid range > 2.0 A; < -2.0 A
|
- LIN communication = active
- Vehicle high voltage system = active
- A/C compressor speed request ≥ 800 RPM
|
- 5 failure counts out of 5 samples 100.0 ms / sample on start up and on every rerun
|
- Difference between measured A/C compressor motor phase V sensor current and expected phase U current value exceeds valid range > 20 (from -14.7 A) %
|
- Difference between A/C compressor current sensor and model based A/C compressor current out of A/C compressor phases current sensor values exceeds valid range > 25%
|
- LIN communication = active
- Vehicle high voltage system = active
- A/C compressor speed. 2, 000 RPM
- A/C compressor speed < 6, 000 RPM
- A/C compressor current sensor > 1.0 A
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
| P0EBC A/C Refrigerant Temperature Sensor "A" Circuit |
P/T Sensor Temperature Sensor "A" |
- Corresponding internal voltage > 0.32 V
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
- Corresponding internal voltage < 0.08 V
|
- Corresponding internal resistance > 32.0 mΩ
|
| P0EBD A/C Refrigerant Temperature Sensor "A" Circuit High |
P/T Sensor Temperature Sensor "A" |
- Temperature value above valid range received from sensor > 120° C
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EBE A/C Refrigerant Temperature Sensor "A" Circuit Low |
P/T Sensor Temperature Sensor "A" |
- Temperature value below valid range received from sensor < -38° C
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EBF A/C Refrigerant Temperature Sensor "A" Range/Performance |
P/T Sensor Temperature Sensor "A" |
- Difference between refrigerant temperature sensor value and internal temperature sensor value exceeds valid range > 15
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EC1 A/C Refrigerant Temperature Sensor "B" Circuit |
P/T Sensor Temperature Sensor "B" |
- Measured temperature value > 150; < -40
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EC2 A/C Refrigerant Temperature Sensor "B" Circuit High |
P/T Sensor Temperature Sensor "B" |
- Temperature value above valid range received from sensor > 120° C
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EC3 A/C Refrigerant Temperature Sensor "B" Circuit Low |
P/T Sensor Temperature Sensor "B" |
- Temperature value below valid range received from sensor < -38° C
|
- LIN communication = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EC5 A/C Compressor Motor Speed Sensor Range/Performance |
Electric A/C Compressor Motor Speed |
- Difference between requested A/C compressor speed and actual A/C compressor speed > 200 RPM
|
- LIN communication = active
- Vehicle high voltage system = active
- Constant A/C compressor speed request for > 30.0 s
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| P0EC7 A/C Power Supply Relay Control Circuit Low |
12V Relay |
- Relay driver feedback voltage < 1.5 V
|
|
|
|
| P0EC8 A/C Power Supply Relay Control Circuit High |
12V Relay |
- Relay driver feedback voltage > 3.5 V
|
|
|
|
| P0EC9 A/C Refrigerant Distribution Valve "A" Stuck/Open |
Refrigerant Distribution Valve |
- Filtered battery inlet coolant temperature decrease ≥ 1.5 K
|
- LIN communication = active
- Battery coolant request = none
- A/C compressor speed ≥ 750 RPM
- Coolant pump speed ≥ 10%
- For at least ≥ 30.0 s
- Vehicle shutdown-time (is equal to vehicle shutdown time without refrigerant system activity) ≥ 6.0 h
- Initial battery inlet coolant temperature at monitoring start (battery cooling circuit) > 25° C
- Battery inlet coolant temperature decrease before A/C compressor activity < 3 K
- Initial ambient temperature ≥ initial battery temperature + 2° C
- Ambient temperature change while monitoring < 4 K
- Concerning other ECUs:
- Vehicle shutdown time monitoring in ECM no failures detected
- Battery inlet coolant sensor monitoring in BECM no failures detected
- Battery coolant distribution valve monitoring in BECM no failures detected
- Battery cooling monitoring in BECM no failures detected
- Battery temperature sensor monitoring in BECM no failures detected
- Ambient air temperature sensor monitoring in ECM no failures detected
|
|
|
| P1296 Malfunction In Cooling System |
Refrigerant Distribution Valve |
- Filtered battery inlet coolant temperature increase ≥ 0.5 K
|
- LIN communication = active
- Battery coolant request = active
- Battery coolant distribution valve position = active battery cooling
- A/C compressor speed ≥ 750 RPM
- For at least (cumulative) ≥ 207.0 s
- Battery coolant pump speed (battery cooling circuit) ≥ 20%
- Initial battery inlet coolant temperature at active battery cooling request (battery cooling circuit) ≥ 30° C
- Battery inlet coolant temperature ≤ battery temperature + 1° C
- Concerning other ECUs:
- Battery inlet coolant sensor monitoring in BECM no failures detected
- Battery coolant distribution valve monitoring in BECM no failures detected
- Battery cooling monitoring in BECM no failures detected
- Battery temperature sensor monitoring in BECM no failures detected
|
|
|
| P165D Refrigerant Pressure Too High |
Refrigerant Circuit High Pressure Monitoring |
- Refrigerant high pressure count (high pressure is counted when system pressure exceeds 32 bar) ≥ 21 [-]
|
- LIN communication = active
- Radiator fan operating status = no error detected
- For activation:
- Refrigerant high pressure count ≥ 20 -
- Vehicle speed once ≥ 20 km/h
- A/C compressor speed once > 0 RPM
- Concerning other ECUs:
- Vehicle speed sensor monitoring in BSCM = no failures detected
- Radiator fan monitoring in ECM = no failures detected
|
|
|
- Refrigerant system pressure sensor value is between [] and [] < 32 bar; > 27 bar
|
- LIN communication = active
- Refrigerant high pressure count ≥ 1 [-]
|
|
|
| P2612 A/C Refrigerant Distribution Valve "A" Control Circuit Low |
Refrigerant Distribution Valve |
- Valve driver feedback voltage < 1.5 V
|
|
|
|
- Valve driver feedback current > 6.0 A
|
| P2613 A/C Refrigerant Distribution Valve "A" Control Circuit High |
Refrigerant Distribution Valve |
- Valve driver feedback voltage > 3.5 V
|
|
|
|
- Valve driver feedback current < 30.0 mA
|
|
| P26FD A/C Compressor Internal Control Module Performance |
Electric A/C Compressor ECU |
- CPU internal self check for bridge driver = invalid [-]
- Calculated checksum != stored checksum for any ROM-part except boot loader [-]
- Calculated EEPROM checksum != stored EEPROM Checksum [-]
- Last reset reason = watchdog timeout [-]
- ADC query time < ADC sample time [-]
|
- LIN communication = active
- Vehicle high voltage system = active
|
- 5 failure counts out of 5 samples 100.0 ms / sample continuous
|
|
| U0010 Medium Speed CAN Communication Bus |
CAN: Medium Speed CAN |
- CAN bus controller flag = bus off [-]
|
|
|
|
| U0011 Medium Speed CAN Communication Bus Performance |
CAN: Medium Speed CAN |
- Global CAN message time out counter = expired [-]
|
|
|
|
| U0073 Control Module Communication Bus "A" Off |
CAN: Engine Control Module (ECM) Engine Cooling Fan Monitoring |
- LIN controller flag = bus off
- Or
- LIN message from electric A/C compressor and refrigerant pressure and temperature sensor = no response
|
|
|
|
| U0100 Lost Communication With ECM/PCM "A" |
CAN: Engine Control Module (ECM) OBD Exhaust Type Monitoring |
- CAN message timeout counter = expired [-]
|
|
|
|
| U0111 Lost Communication With Battery Energy Control Module "A" |
CAN: Battery Energy Control Module (BECM) Temperature Monitoring |
- CAN message timeout counter = expired [-]
|
|
|
|
| U0121 Lost Communication With Anti-Lock Brake System (ABS) Control Module |
CAN: Brake System Control Module (BSCM) Vehicle Speed Sensor |
- CAN message timeout counter = expired [-]
|
|
|
|
| U0140 Lost Communication With Body Control Module |
CAN: Body Control Module (BCM) Ignition Monitoring |
- CAN message timeout counter = expired [-]
|
|
|
|
| U016B Lost Communication With A/C Compressor Control Module |
Electric A/C Compressor ECU |
- LIN message from electric A/C compressor no response [-]
|
- Time after ignition on ≥ 500.0 ms
|
|
|
| U019B Lost Communication With Battery Charger Control Module |
CAN: Battery Charger Control Module (BCCM) Pre Conditioning Monitoring |
- CAN message timeout counter = expired [-]
|
|
|
|
| U0401 Invalid Data Received From ECM/PCM "A" |
CAN: Engine Control Module (ECM) Engine Cooling Fan Monitoring |
- Information content = undefined [-]
|
|
|
|
| U0412 Invalid Data Received From Battery Energy Control Module "A" |
CAN: Battery Energy Control Module (BECM) Temperature Monitoring |
- Information content = undefined [-]
|
|
|
|
| U046C Invalid Data Received From A/C Compressor Control Module |
Electric A/C Compressor ECU |
- LIN message from electric A/C compressor = incomplete
- Or
- Value received from electric A/C compressor = response error
- Or
- LIN message checksum = invalid
- Or
- Value received from electric A/C compressor = undefined
|
|
|
|
| U0605 Lost Communication With A/C Refrigerant Sensor "A" |
P/T Sensor |
- LIN message from refrigerant pressure and temperature sensor no response [-]
|
- Time after ignition on ≥ 500.0 ms
|
|
|
- LIN message from refrigerant pressure and temperature sensor = incomplete
- Or
- Value received from slave = response error
- Or
- LIN message checksum = invalid
|
|
| U1103 Production Mode Active |
Production Vehicle Mode |
- Production mode flag = active [-]
|
|
|
|