| 1 |
Activate Monitors:
- Perform the function test in the appropriate Diagnostic Mode 06. Refer to DIAGNOSTIC MODES 01 - 0A
.
- End diagnosis and switch the ignition off.
- If the specified values are exceeded:
|
- Check the exhaust system for leaks.
- If necessary, repair the leak(s) in the exhaust system.
- GO TO: Step 2.
|
| 2 |
O2 Sensor Monitoring:
|
- Generate readiness code. Refer to READINESS CODE
.
- If no leaks are found in the exhaust system:
- Replace the catalytic converter with front exhaust pipe. Refer to appropriate service information.
- GO TO: Step 3 below.
|
| 3 |
- Final procedure:
- Perform a road test to verify repair.
|
|