BASEPLATE FOR Distance Regulation Control Module -J428-, REMOVING AND INSTALLING, VERSION 2 THROUGH MY 2016: Installing
Install in the reverse order of removal. Note the following:
NOTE:
Replace the quick release.
The stud bolts in the adapter frame are pre-set. If necessary, correct the setting.
-- Place the control module on a soft and clean surface.
-- Measure the dimension -a- at all stud bolts using the :VAS6335 and correct if necessary.
- Dimension -a- = 40.3 ± 0.5 mm
-- Position the retaining plate -3- onto the distance regulation control module -1-.
-- Carefully press the new quick release -4- onto the stud bolt -2-.
-- Turn the quick release clockwise onto the retaining plate to the stop -arrow-.