Distance Regulation Control Module -J428- Retaining Plate, Removing And Installing, Version 1: Installing
Install in the reverse order of removal. Note the following:
Replace the quick release.
The stud bolts in the bracket are pre-set. If necessary, correct the setting.
If the stud bolts were removed, then the clips on the distance regulation control module must be replaced. Refer to CLIP ON Distance Regulation Control Module -J428-, REPLACING, VERSION 1 .
-- Place the control module on a soft and clean surface.
-- Measure the dimension -a- at all stud bolts using the :VAS6335 and correct if necessary.
- Dimension -a- = 44.3 mm.
-- Position the retaining plate -3- onto the distance regulation control module -1-.
-- Carefully press the new quick release -4- onto the stud bolt -2-.
-- Turn the quick release clockwise onto the retaining plate to the stop in direction of -arrow-.