LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2018 >> Q5 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 13 (Communication) >> 91 Communication >> Navigation System >> Chip Card Reader Control Module, Removing And Installing >> Removing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Chip Card Reader Control Module, Removing And Installing: Removing

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

-- Turn off the ignition and all electrical equipment and remove the ignition key.

-- Open the glove compartment.

-- Remove the chip card from the Chip Card Reader Control Module -J676-.

-- Slide the Chip Card Reader Control Module -J676- -1- back in the direction of -arrow- until it can be removed from the trim.

GWWA91-12286Courtesy of AUDI OF AMERICA, LLC

-- Release and disconnect the connectors from the Chip Card Reader Control Module -J676- -1-.

-- Remove the Chip Card Reader Control Module -J676-.