Home >> Audi >> 2018 >> RS 7 Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System (General Information) >> 27 Starter, Generator And Battery >> Battery, Checking >> Test Sequence >> Checking The Battery - Vehicles Without A Battery Monitoring Control Module -J367- Or Energy Management Control Module -J644-
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Checking The Battery - Vehicles Without A Battery Monitoring Control Module -J367- Or Energy Management Control Module -J644-

CAUTION:

It is not possible to check the battery using "Guided Fault Finding" through MY 2010 during the following procedure, even if the vehicle has a Battery Monitoring Control Module -J367- :

  • A3 from MY 2004 (8P)
  • TT from MY 2007 (8J)
  • R8 from My 2007 (42)
WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

Perform The Tests In The Following Sequence: 

-- Visual inspection. Refer to VISUAL INSPECTION .

-- Check the visual indicator color display (if equipped). Refer to VISUAL INDICATOR COLOR DISPLAY, CHECKING .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

NOTE:

The :VAS5097A  will no longer be used for warranty testing. Only the :VAS6161  is still being used.

-- Battery test with:

-- Depending on the result of the battery load test, "perform current draw test". Refer to CURRENT DRAW TEST .