BASEPLATE FOR Distance Regulation Control Module -J428-, REMOVING AND INSTALLING, VERSION 2 AND RS3 FROM MY 2017: Removing
-- Remove the distance regulation control module. Refer to Distance Regulation Control Module -J428-, REMOVING AND INSTALLING .
-- Release the retainers -1- in direction of -arrow-.
-- Remove the cover -2- from the distance regulation control module -3-.
-- Release the locking mechanisms -2- in direction of -arrow-.
-- Remove the distance regulation control module from the stud bolts -1-.
-- Remove the retaining plate -3- from the Distance Regulation Control Module -J428- -4-.