Home >> Audi >> 2021 >> A8 e Quattro >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool [CZSE] (Hybrid) (Battery Charger Control Module) >> St Generic Scan Tool >> Diagnosis And Testing >> Battery Energy Control Module >> Battery Energy Control Module --, 2021 MY
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Battery Energy Control Module --, 2021 MY

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
Battery Energy Control Module (BECM) - Hardware/Internal Malfunctions
BECM: Performance (Self Test) P0A1F internal hardware check CPU test failed         5 [ms] On Mode Change (except to EMERGENCY_OFF or LOCAL_ACTIVE) 0 DCY
OR  
RAM test failed
OR  
ROM test failed
BECM: Internal Control Module P0604 Random Access Memory (RAM) check secured internal data exchange failed         5 [ms] continuous 0 DCY
BECM: Internal Control Module P062F EEPROM check memory checksum error detected         1 [s] multiple 0 DCY
BECM: Hybrid CAN Controller P163E CAN RAM check read/write check in hybrid CAN-RAM failed   BECM mode = INIT   5 [ms] once / DCY 0 DCY
BECM: Battery CAN Controller P163E CAN RAM check read/write check in battery CAN-RAM failed   BECM mode = INIT   5 [ms] once / DCY 0 DCY
BECM: Control Module Processor P0606 watchdog reset watchdog reset occurred         5 [ms] continuous 0 DCY
BECM: Control Module U3001 improper shutdown performance incorrect BECM postrun execution (aborted or not started) 5 times in a row   BECM mode = INIT   150 [ms] once / DCY 0 DCY
at least one OBD-relevant monitoring failed and pending
BECM: Battery Monitor Module - Daisy Chain Input P058D voltage monitoring performance (short to battery) CASE 1:     (BECM mode = AC_CHARGING   2 [s] continuous 0 DCY
ratio of BECM Daisy Chain input voltage to battery voltage > 0.9 [-]   OR
      BECM mode = EMERGENCY_OFF
CASE 2:       OR
BECM Daisy Chain input voltage > 4 [V] BECM mode = HV_OFF
Critical over voltage/under voltage condition of any cell voltage reported     OR
      BECM mode = HV_ON
        OR
      BECM mode) = INIT
      Battery CAN communication active
      error memory status flags of all CMCs valid
BECM: Battery Monitor Module - Daisy Chain Input P058D voltage monitoring performance (short to ground) BECM Daisy Chain input voltage < 4 [V] (BECM mode = AC_CHARGING   2 [s] continuous 0 DCY
No Critical over voltage/under voltage condition of any cell voltage reported   OR
    BECM mode = EMERGENCY_OFF
      OR
    BECM mode = HV_OFF
      OR
    BECM mode = HV_ON
      OR
    BECM mode) = INIT
    Battery CAN communication active
    error memory status flags of all CMCs valid
BECM: Battery Monitor Module - Daisy Chain Output P058D voltage monitoring performance (short to battery) BECM Daisy Chain output voltage > 4 [V] (BECM mode = AC_CHARGING   5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode) = INIT
BECM Daisy Chain output target value = 0
BECM: Battery Monitor Module - Daisy Chain Output P058D voltage monitoring performance (short to ground) BECM Daisy Chain output voltage < 4 [V] (BECM mode = AC_CHARGING   5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode) = INIT
BECM Daisy Chain output target value = 1
BECM: Internal Control Module - Hardware Disable Output P0E2D hybrid/EV battery monitor performance (short to battery) Hardware-Disable output voltage > 10 [V] (BECM mode = AC_CHARGING   5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode) = INIT
BECM HW Disable output target value = 0
BECM: Internal Control Module - Hardware Disable Output P0E2D hybrid/EV battery monitor performance (short to ground) Hardware-Disable output voltage < 4 [V] (BECM mode = AC_CHARGING   5 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
              OR      
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode) = INIT
BECM HW Disable output target value = 1
BECM: High-Voltage System Interlock P0A0D circuit "A" high (short to battery) voltage drop across shunt > 5 [V]       500 [ms] continuous 0 DCY
BECM: High-Voltage System Interlock P0A0C circuit "A" low (short to ground) voltage drop across shunt < 0.2 [V]       500 [ms] continuous 0 DCY
BECM: High-Voltage System Interlock P0A0A HV interlock implausible HV interlock loop current < 8 [mA]       100 [ms] continuous 0 DCY
OR      
HV interlock loop current > 12 [mA]  
BECM: High-Voltage System Interlock P0A0B performance (internal circuit) Value measured by HV interlock ADC with input signal set to ground level (0 V) > 51.57 [mV] (BECM mode = AC_CHARGING   500 [ms] continuous 0 DCY
OR       OR
Value measured by HV interlock ADC with input signal set to reference voltage (3.3 V) <3248.43 [mV] BECM mode = EMERGENCY_OFF
OR       OR
HV Interlock ADC values not received   BECM mode = HV_OFF
for time 10 [ms]   OR
      BECM mode = HV_ON
        OR
      BECM mode) = INIT
BECM: Control Module Power Off Timer P262B plausibility check A - MAX check (rationality check high) CASE 1:     BECM mode = RUN_ON [s] 0 [s] once / DCY 2 DCY
0.06 * actual postrun timer ≤ 1 [s] HV Supply switched off
AND     for time ≥ 5
actual postrun timer - HV off hardware timer value ≥ 1 [s]    
CASE 2:        
0.06 * actual postrun timer > 1 [s]    
AND        
ratio of HV off hardware timer value to actual postrun time ≥ 1.06 [-]    
BECM: Control Module Power Off Timer P262B plausibility check A - MIN check (rationality check low) CASE 1:     BECM mode = RUN_ON [s] 0 [s] once / DCY 2 DCY
0.06 * actual postrun timer ≤ 1 [s] HV Supply switched off
AND     for time ≥ 5
HV off hardware timer value - actual postrun timer ≥ 1 [s]    
CASE 2:        
0.06 * actual postrun timer > 1 [s]    
AND        
ratio of HV off hardware timer value to actual postrun time ≤ 0.94 [-]    
BECM: Control Module Power Off Timer P262B plausibility check B - MIN check (rationality check low) ratio of HV off hardware timer value to last stored internal postrun time ≤ 0.94 [-] BECM mode = INIT   0 [s] once / DCY 2 DCY
BECM: Control Module Power Off Timer P262B plausibility check C (internal circuit) Response from HV Off Hardware Timer circuit during initialization not received         40 [ms] once / DCY 2 DCY
OR  
Response from HV Off Hardware Timer circuit invalid
Battery Energy Control Module (BECM) - Software Version / Calibration Monitoring
BECM: Dataset Implausible B2012 compatibility check dataset and hardware/software not compatible   BECM mode = INIT   5 [ms] once / DCY 0 DCY
BECM: Dataset Invalid B2005 dataset check dataset invalid   BECM mode = INIT   5 [ms] once / DCY 0 DCY
BECM: Production Mode P0610 vehicle in production mode production mode active   for activation: < 100 [km] 5 [s] once / DCY 0 DCY
max mileage since initial vehicle start-up
BECM: OBD Settings Incompatible P064F compatibility check internal OBD settings and vehicle OBD settings not compatible   valid message containing vehicle OBD settings received   2.9 [s] continuous 0 DCY
Battery Energy Control Module (BECM) - Cooling System
Hybrid/EV Battery Pack Coolant Pump Supply Voltage P0C4D circuit high supply voltage @ coolant pump > 0.4 [V] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
Hybrid/EV Battery Pack Coolant Pump Supply Voltage P0C4C circuit low ratio of supply voltage @ coolant pump to 12 V supply voltage < 0.9 [-] coolant pump switched on   5 [s] continuous 2 DCY
AND  
BECM mode = AC_CHARGING
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode HV_OFF
  OR
BECM mode = HV_ON

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
Hybrid/EV Battery Pack Coolant Pump "A" Control P0C49 circuit high time duration of high signal sent by pump ≥ 10 [s] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
Hybrid/EV Battery Pack Coolant Pump "A" Control P0C48 circuit low time duration of ground signal sent by pump ≥ 2 [s] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
Hybrid/EV Battery Pack Coolant Pump "A" Control P0C47 circuit open (functional check: time out) alive signal (PWM signal) missing         39.5 [s] continuous 2 DCY
Hybrid/EV Battery Pack Coolant Pump "A" P0C4A performance (functional check: dry run) time duration of ground signal sent by pump > 900 [ms] coolant pump commanded on % 7.2 [s] continuous 2 DCY
  <1100 [ms] pump time out monitoring passed
AND     PWM duty cycle > 85
pause time between ground signal sent by pump > 900 [ms]    
  <1100 [ms]    
Hybrid/EV Battery Pack Coolant Pump P0CFF functional check: stuck/stalled time duration of ground signal sent by pump >1400 [ms] coolant pump commanded on % 21 [s] continuous 2 DCY
  < 1600 [ms] pump time out monitoring passed
AND     PWM duty cycle > 25
pause time between ground signal sent by pump > 900 [ms]    
  <1100 [ms]    
Hybrid/EV Battery Pack Coolant Pump "A" P0C4A performance (functional check: overheating) time duration of ground signal sent by pump >1900 [ms] coolant pump commanded on   8.2 [s] continuous 2 DCY
AND < 2100 [ms] pump time out monitoring passed
pause time between ground signal sent by pump > 900 [ms]    
  <1100 [ms]    
Battery Energy Control Module (BECM) - Cooling Temperature Sensors
Coolant Temperature Sensor at HV Battery Inlet P0C45 circuit high (short to battery) signal value of temperature voltage @ HV battery inlet > 3248.44 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
Coolant Temperature Sensor at HV Battery Inlet P0C44 circuit low (short to ground) signal value of temperature voltage @ HV battery inlet < 48.34 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
Coolant Temperature Sensor at HV Battery Inlet P0C42 open circuit signal value of temperature voltage @ HV battery inlet > 3125.98 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
< 3158.20 [mV]   OR
    BECM mode = EMERGENCY_OFF
      OR
    BECM mode = HV_OFF
      OR
    BECM mode = HV_ON
      OR
    BECM mode = INIT
Coolant Temperature Sensor at HV Battery Inlet P0C44 circuit low (out of range low) signal value of temperature voltage @ HV battery inlet > 48.34 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
< 325.48 [mV]   OR
    BECM mode = EMERGENCY_OFF
      OR
    BECM mode = HV_OFF
      OR
    BECM mode = HV_ON
      OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = INIT      
Coolant Temperature Sensor at HV Battery Inlet P0C45 circuit high (out of range high) signal value of temperature voltage @ HV battery inlet > 3019.63 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  < 3125.98 [mV]   OR
OR     BECM mode = EMERGENCY_OFF
signal value of temperature voltage @ HV battery inlet > 3158.20 [mV]   OR
  < 3248.44 [mV] BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
        OR
      BECM mode = INIT
Coolant Temperature Sensor at HV Battery Inlet P0C43 range/performance (rationality high) difference between coolant temperature @ HV battery inlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≥ 15...21 [°C] HV off time calculations status time calculated [min] 1.5 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Coolant Temperature Sensor at HV Battery Inlet P0C43 range/performance (rationality low) difference between coolant temperature @ HV battery inlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≤ -15...-21 [°C] HV off time calculations status time calculated [min] 1.5 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Coolant Temperature Sensor at HV Battery Outlet P0CD8 circuit high (short to battery) signal value of temperature voltage @ HV battery outlet > 3248.44 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
Coolant Temperature Sensor at HV Battery Outlet P0CD7 circuit low (short to ground) signal value of temperature voltage @ HV battery outlet < 48.34 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
Coolant Temperature Sensor at HV Battery Outlet P0CD5 open circuit signal value of temperature voltage @ HV battery outlet > 3125.98 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
< 3158.20 [mV]   OR
    BECM mode = EMERGENCY_OFF
      OR
    BECM mode = HV_OFF
      OR
    BECM mode = HV_ON
      OR
    BECM mode = INIT
Coolant Temperature Sensor at HV Battery Outlet P0CD7 circuit low (out of range low) signal value of temperature voltage @ HV battery outlet > 48.34 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
< 325.48 [mV]   OR
    BECM mode = EMERGENCY_OFF
      OR
    BECM mode = HV_OFF
      OR
    BECM mode = HV_ON

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode OR      
= INIT
Coolant Temperature Sensor at HV Battery Outlet P0CD8 circuit high (out of range high) signal value of temperature voltage @ HV battery outlet > 3019.63 [mV] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  < 3125.98 [mV]   OR
OR     BECM mode = EMERGENCY_OFF
signal value of temperature voltage @ HV battery outlet > 3158.20 [mV]   OR
  < 3248.44 [mV] BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
        OR
      BECM mode = INIT
Coolant Temperature Sensor at HV Battery Outlet P0CD6 range/performance (rationality high) difference between coolant temperature @ HV battery outlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≥ 15...21 [°C] HV off time calculations status time calculated [min] 2 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Coolant Temperature Sensor at HV Battery Outlet P0CD6 range/performance (rationality low) difference between coolant temperature @ HV battery outlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≤ -15...-21 [°C] HV off time calculations status time calculated [min] 2 [s]continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Coolant Temperature at Chiller P0CEF range/performance (rationality high) difference between pump coolant temperature and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≥ 15...21 [°C] HV off time calculations status time calculated [min] 2.2 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Coolant Temperature at Chiller P0CEF range/performance (rationality low) difference between pump coolant temperature and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≤ -15...-21 [°C] HV off time calculations status time calculated [min] 2.2 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Battery Energy Control Module (BECM) - High-Voltage System Activation
BJB State Monitoring P33F0 change to HV_ON fails BJB mode != HV_ON   BJB Target mode = HV_ON   1 [s] continuous 0 DCY
BJB State Monitoring P33F0 change to AC_CHARGING fails BJB mode != AC_CHARGING   BJB Target mode = AC_CHARGING   1 [s] continuous 0 DCY
BJB State Monitoring P33F0 emergency shutoff BJB mode = EMERGENCY_OFF   BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = INIT      
Battery Energy Control Module (BECM) - Protective Functions
BECM: Hybrid/EV Battery Charging Current P0CA6 charging current high measured HV battery charge current > 0...240 [A] BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = PRECHARGE
BECM: Hybrid/EV Battery Discharging Current P0CA7 discharging current high measured HV battery discharge current > 0...400 [A] BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = PRECHARGE
BECM: Hybrid/EV Battery System Voltage P0AFB system voltage high pack voltage signal > 448 [V] BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
BECM: Hybrid/EV Battery System Voltage P0AFA system voltage low pack voltage signal < 187 [V] BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-01: Hybrid/EV Battery Interface Control Module "A" P0B26 cell voltage high any cell voltage signal within CMC-01 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-01: Hybrid/EV Battery Interface Control Module "A" P0B25 cell voltage low any cell voltage signal within CMC-01 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-01: Hybrid/EV Battery Interface Control Module "A" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-01 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = EMERGENCY_OFF      
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-02: Hybrid/EV Battery Interface Control Module "B" P0B26 cell voltage high any cell voltage signal within CMC-02 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-02: Hybrid/EV Battery Interface Control Module "B" P0B25 cell voltage low any cell voltage signal within CMC-02 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-02: Hybrid/EV Battery Interface Control Module "B" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-02 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-02: Hybrid/EV Battery Interface Control Module "C" P0B26 cell voltage high any cell voltage signal within CMC-03 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-03: Hybrid/EV Battery Interface Control Module "C" P0B25 cell voltage low any cell voltage signal within CMC-03 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-03: Hybrid/EV Battery Interface Control Module "C" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-03 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = EMERGENCY_OFF      
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-04: Hybrid/EV Battery Interface Control Module "D" P0B26 cell voltage high any cell voltage signal within CMC-04 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-04: Hybrid/EV Battery Interface Control Module "D" P0B25 cell voltage low any cell voltage signal within CMC-04 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-04: Hybrid/EV Battery Interface Control Module "D" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-04 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-05: Hybrid/EV Battery Interface Control Module "E" P0B26 cell voltage high any cell voltage signal within CMC-05 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-05: Hybrid/EV Battery Interface Control Module "E" P0B25 cell voltage low any cell voltage signal within CMC-05 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-05: Hybrid/EV Battery Interface Control Module "E" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-05 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = EMERGENCY_OFF      
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-06: Hybrid/EV Battery Interface Control Module "F" P0B26 cell voltage high any cell voltage signal within CMC-06 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-06: Hybrid/EV Battery Interface Control Module "F" P0B25 cell voltage low any cell voltage signal within CMC-06 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-06: Hybrid/EV Battery Interface Control Module "F" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-06 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-07: Hybrid/EV Battery Interface Control Module "G" P0B26 cell voltage high any cell voltage signal within CMC-07 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-07: Hybrid/EV Battery Interface Control Module "G" P0B25 cell voltage low any cell voltage signal within CMC-07 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-07: Hybrid/EV Battery Interface Control Module "G" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-07 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = EMERGENCY_OFF      
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-08: Hybrid/EV Battery Interface Control Module "H" P0B26 cell voltage high any cell voltage signal within CMC-08 > 4.3 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-08: Hybrid/EV Battery Interface Control Module "H" P0B25 cell voltage low any cell voltage signal within CMC-08 < 1.8...2.0 [V] BECM mode = AC_CHARGING   100 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
CMC-08: Hybrid/EV Battery Interface Control Module "H" P0BBD cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-08 > 0.25 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = INIT
  OR
BECM mode = PRECHARGE
BECM: Daisy Chain Redundant Safety Shutdown P0AF8 redundant safety shutdown due to cell overvoltage/undervoltage BECM Daisy Chain input < 4 [V] BECM mode = AC_CHARGING   500 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = PRECHARGE
BJB: Main Fuse P0A95 rationality check deviation between battery voltage and voltage at main fuse > |20| [V] BECM mode = AC_CHARGING   5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
BJB: Battery Charger Fuse P0E2E rationality check deviation between system voltage and voltage at battery charger fuse > |20| [V] BECM mode = AC_CHARGING   5 [s] continuous 2 DCY
  OR
BECM mode = HV_ON
BECM: Vehicle System - 12 Volt Supply Voltage P0563 system voltage high power supply voltage > 17 [V]       9 [s] continuous 0 DCY
BECM: Vehicle System - 12 Volt Supply Voltage U1401 system voltage high power supply voltage > 17 [V]       10 [ms] continuous 0 DCY
BECM: Vehicle System - 12 Volt Supply Voltage P0562 system voltage low power supply voltage < 8 [V]       9 [s] continuous 0 DCY
BECM: Vehicle System - 12 Volt Supply Voltage U1400 system voltage low power supply voltage < 8 [V]       10 [ms] continuous 0 DCY
BECM: Vehicle System - 12 Volt Supply Voltage U1400 system voltage pre-low power supply voltage < 9 [V]       10 [ms] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
BECM: Crash Detection P1609 crash shut-off was triggered crash detected   System active   0 [ms] continuous 0 DCY
Battery Energy Control Module (BECM) - CAN Communication Monitoring
Hybrid CAN U0028 vehicle communication bus A CAN controller enters "BUS OFF" state 3 times in a row   time after ECU wake up > 500 [ms] 450 [ms] continuous 0 DCY
Hybrid CAN U0029 vehicle communication bus A performance CAN messages not received   time after ECU wake up > 500 [ms] 450 [ms] continuous 0 DCY
Hybrid CAN: Engine Control Module (ECM) U0100 lost communication with ECM/PCM "A" message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
FlexRay active
Hybrid CAN: Engine Control Module (ECM) U0100 lost communication with ECM/PCM "A" message time out detected   time after ECU wake up > 500 [ms] 800 [ms] continuous 0 DCY
FlexRay active
Hybrid CAN: Engine Control Module (ECM) U0100 lost communication with ECM/PCM "A" message time out detected   time after ECU wake up > 500 [ms] 2 [s] continuous 2 DCY
FlexRay active
Hybrid CAN: Engine Control Module (ECM) U0401 invalid data received from ECM/PCM "A" message counter error detected   time after ECU wake up > 500 [ms] 8 [s] continuous 0 DCY
valid message from ECM received
Hybrid CAN: Engine Control Module (ECM) U0401 invalid data received from ECM/PCM "A" checksum error detected   time after ECU wake up > 500 [ms] 2.5 [s] continuous 0 DCY
valid message from ECM received
Hybrid CAN: Engine Control Module (ECM) U0401 invalid data received from ECM/PCM "A" received message implausible message   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
valid message from ECM received
Hybrid CAN: Body Control Module "A" U0140 lost communication with Body Control Module message time out detected   time after ECU wake up > 500 [ms] 2 [s] continuous 2 DCY
Comfort CAN active
Hybrid CAN: Body Control Module "A" U0141 lost communication with Body Control Module "A" message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
ComfortCAN active
Hybrid CAN: Gateway "A" U0146 lost communication with Gateway "A" message time out detected   (BECM mode = AC_CHARGING [ms] 1 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
time after ECU wake up > 500
any Hybrid CAN message received
Hybrid CAN: Gateway "A" U0447 invalid data received from Gateway "A" message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from Gateway received
Hybrid CAN: Gateway "A" U0447 invalid data received from Gateway "A" checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from Gateway received
Hybrid CAN: Gateway "A" U0447 invalid data received from Gateway "A" BECM target mode != AC_CHARGING   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
!= HV_OFF valid message from Gateway received
!= HV_ON    
Hybrid CAN: Battery Charger Control Module (BCCM) U019B lost communication with Battery Charger Control Module "A" message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
    Hybrid CAN communication active
Hybrid CAN: Battery Charger Control Module (BCCM) U019B lost communication with Battery Charger Control Module "A" message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
Hybrid CAN communication active
Hybrid CAN: Battery Charger Control Module (BCCM) U019B lost communication with Battery Charger Control Module "A" message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
Hybrid CAN communication active
Hybrid CAN: Coolant Temperature Control Module U0116 lost communication with Coolant Temperature Control Module message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 2 DCY
Hybrid CAN communication active
Hybrid CAN: Coolant Temperature Control Module U0116 lost communication with Coolant Temperature Control Module message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
Hybrid CAN communication active
Hybrid CAN: Coolant Temperature Control Module U0456 invalid data received from Coolant Temperature Control Module received message implausible message   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
    valid message from VTMC received
Hybrid CAN: Coolant Temperature Control Module U0456 invalid data received from Coolant Temperature Control Module received message implausible message   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
valid message from VTMC received
Battery CAN U0037 vehicle communication bus B CAN controller enters "BUS OFF" state 3 times in a row   time after ECU wake up > 500 [ms] 10 [ms] continuous 0 DCY
Battery CAN U0038 vehicle communication bus B performance (global time out) CAN messages not received   time after ECU wake up > 500 [ms] 450 [ms] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 500 [ms] continuous 0 DCY
    any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wake up > 500 [ms] 500 [ms] continuous 0 DCY
      valid message from BJB received  
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wake up > 500 [ms] 20 [ms] continuous 0 DCY
      valid message from BJB received  
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wake up > 500 [ms] 4 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from BJB received      
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wake up > 500 [ms] 4 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wake up > 500 [ms] 4 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wake up > 500 [ms] 4 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wake up > 500 [ms] 4 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
any Battery CAN message received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 800 [ms] continuous 0 DCY
    valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 800 [ms] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 800 [ms] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from BJB received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      CMC power supply active  
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      valid message from CMC-01 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-01 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-01 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U04A1 invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-01 received
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      CMC power supply active  
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      valid message from CMC-02 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-02 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-02 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U04A2 invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-02 received
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      CMC power supply active  
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      valid message from CMC-03 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-03 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-03 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U04A3 invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-03 received
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      CMC power supply active  
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      valid message from CMC-04 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-04 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U02A0 invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-04 received
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-05 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-05 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U04A5 invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-05 received
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      valid message from CMC-06 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-06 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-06 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U04A6 invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-06 received
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      CMC power supply active  
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
      valid message from CMC-07 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
      valid message from CMC-07 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-07 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U04A7 invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-07 received
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    CMC power supply active  
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-08 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
    valid message from CMC-08 received  
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 2 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 200 [ms] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            valid message from CMC-08 received      
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) received message implausible   time after ECU wake up > 500 [ms] 1 [s] continuous 0 DCY
    valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U04A8 invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) received message implausible   time after ECU wake up > 500 [ms] 5 [s] continuous 0 DCY
valid message from CMC-08 received
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message time out detected   time after ECU wake up > 500 [ms] 5 [s] continuous 2 DCY
CMC power supply active
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) BJB error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "A" (CMC-01) P0DAF range/performance (invalid data) (CMC-01) CMC-01 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "B" (CMC-02) P0DB3 range/performance (invalid data) (CMC-02) CMC-02 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "C" (CMC-03) P0DB7 range/performance (invalid data) (CMC-03) CMC-03 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "D" (CMC-04) P0DBB range/performance (invalid data) (CMC-04) CMC-04 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "E" (CMC-05) P0DBF range/performance (invalid data) (CMC-05) CMC-05 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "F" (CMC-06) P0DC3 range/performance (invalid data) (CMC-06) CMC-06 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
              OR      
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "G" (CMC-07) P0DC7 range/performance (invalid data) (CMC-07) CMC-07 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "H" (CMC-08) P0DCB range/performance (invalid data) (CMC-08) CMC-08 error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Battery CAN communication active
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Hardware/Internal Malfunctions
BJB: Internal Hardware Check (Self Test) P0AFC internal hardware check (self test) CASE 1:     CASE 1:     CASE 1: 0 DCY
crash self test not completed   BJB mode = INIT 4.5 [s]
OR     Battery CAN communication active  
non-volatile memory reading not completed   BJB error memory status flag valid CASE 2:
OR         550 [ms]
sensor data not available   CASE 2 to 9:    
OR     Battery CAN communication active CASE 3:
hardware revision not available   BJB error memory status flag valid 1 [s]
CASE 2:         CASE 4:
contactor control command and contactor control feedback signal not equal       5500 [ms]
CASE 3:         CASE 5:
Mosfet control command and mosfet control feedback signal not equal       1 [s]
CASE 4:         CASE 6:
Difference between temperature @ control board NTC and temperature @ shunt NTC 1 > |20| [°C]     1 [s]
OR          
Difference between temperature @ shunt NTC 1 and temperature @ shunt NTC 2 > |20| [°C]     CASE 7:
CASE 5:         550 [ms]
deviation between positive battery voltage and voltage @ main fuse > |20| [V]     CASE 8:
CASE 6:         750 [ms]
deviation between positive system voltage and voltage @ battery charger fuse > |20| [V]     CASE 9:
CASE 7:         550 [ms]
ADC internal reference voltage of main processor ≥1.32 [V]      
OR          
ADC internal reference voltage of main processor ≤ 1.08 [V]      
CASE 8:          
HV isolated positive supply voltage > 7 [V]      
OR < 5.5 [V]      
HV isolated negative supply voltage > -2 [V]      
CASE 9: < -6 [V]      
3.3V supply voltage > 3.6 [V]      
OR < 3 [V]      
5V supply voltage > 5.4 [V]      
  < 4.6 [V]      

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
BJB: Internal Memory P0AFC RAM check CASE 1:     CASE 1:     CASE 1: 0 DCY
error correcting code failure detected BECM mode = INIT 850 [ms] once / DCY
CASE 2:   CASE 1 & 2:   CASE 2:
ECC correction check logic failed Battery CAN communication active 500 [ms] continuous
    BJB error memory status flag valid  
BJB: EEPROM P0AFC EEPROM check memory checksum error detected   BECM mode = INIT   850 [ms] once / DCY 0 DCY
Battery CAN communication active
BJB error memory status flag valid
BJB: Analog-to-Digital-Converter 1 P0AFC analog-to -digital converter 1 internal hardware check internal reference voltage > 5.5 [V] Battery CAN communication active   750 [ms] continuous 0 DCY
< 4.5 [V] BJB error memory status flag valid
BJB: Analog-to-Digital-Converter 2 P0AFC analog-to -digital converter 2 internal hardware check CASE 1:     CASE 1 & 2:     CASE 1 & 3 & 4: 0 DCY
internal reference voltage for current measurement >130 [mV] BECM mode = INIT 700 [ms] continuous
  <110 [mV] Battery CAN communication active  
OR     BJB error memory status flag valid CASE 2:
internal reference voltage for voltage measurement > 1.2 [V]     5.5 [s] continuous
  < 0.8 [V] CASE 3 & 4:    
OR     Battery CAN communication active  
internal resistance ratio for temperature measurement > 0.763 [%] BJB error memory status flag valid  
CASE 2: < 0.534 [%]      
main processor data not received        
CASE 3:          
ADC values not received        
CASE 4:          
shunt resistance > 1.25 [MOhm]      
BJB: Hardware Disable Malfunction P0AFC plausibility check CASE 1:     Battery CAN communication active   CASE 1: 0 DCY
Hardware-Disable output voltage > 3.703 [V] BJB error memory status flag valid 1.5 [s] continuous
Hardware-Disable comparator output 0        
OR         CASE 2 to 6:
Hardware-Disable output voltage < 2.381 [V]     2.5 [s] continuous
Hardware-Disable comparator output 1        
CASE 2:          
car crash detected        
contactor power supply activity signal active        
CASE 3:          
emergency off command issued        
contactor power supply activity signal active        
CASE 4:          
contactor power supply output voltage < 4 [V]      
contactor power supply activity signal active        
CASE 5:          
contactor power supply output voltage > 6 [V]      
contactor power supply activity signal inactive        
CASE 6:          
Hardware-Disable output voltage > 3.703 [V]      
Hardware-Disable comparator output 1        
contactor power supply input voltage < 16.2 [V]      
contactor power supply input voltage > 7.8 [V]      
car crash not detected        
contactor power supply activity signal inactive        
contactor power supply output voltage <4 [V]      
BJB: Hardware Disable Line P0E2D performance (circuit high/out of range high) CASE 1: short to battery     Battery CAN communication active   1 [s] continuous 0 DCY
measured voltage > 17 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured voltage > 16 [V]    
  ≤ 17 [V]    

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
BJB: Hardware Disable Line P0E2D performance (open circuit) actual value of Hardware-Disable state = disable   target value of Hardware-Disable state = enable   600 [ms] continuous 0 DCY
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Current Sensors
BJB: Hybrid/EV Battery Pack Current Sensor "A" P0AC2 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 0 DCY
measured shunt current > 455 [A] BJB error memory status flag valid
CASE 2: out of range high        
measured shunt current > 400 [A]    
  ≤ 455 [A]    
BJB: Hybrid/EV Battery Pack Current Sensor "A" P0AC1 circuit low/out of range low CASE 1: circuit low     Battery CAN communication active   1 [s] continuous 0 DCY
measured shunt current < -455 [A] BJB error memory status flag valid
CASE 2: out of range low        
measured current < -400 [A]    
  ≥ -455 [A]    
BJB: Hybrid/EV Battery Pack Current Sensor "A" P0AC0 circuit range/performance (internal hardware check) internal communication time out detected   Battery CAN communication active   700 [ms] continuous 0 DCY
BJB error memory status flag valid
BJB: Hybrid/EV Battery Pack Current Sensor "B" P0B11 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 2 DCY
measured hull current > 455 [A] BJB error memory status flag valid
CASE 2: out of range high        
measured hull current > 400 [A]    
  ≤ 455 [A]    
BJB: Hybrid/EV Battery Pack Current Sensor "B" P0B10 circuit low/out of range low CASE 1: circuit low     Battery CAN communication active   1 [s] continuous 2 DCY
measured hull current < -455 [A] BJB error memory status flag valid
CASE 2: out of range low        
measured hull current < -400 [A]    
  ≥ -455 [A]    
BJB: Hybrid/EV Battery Pack Current Sensor "B" P0B0F circuit range/performance (internal hardware check) deviation between sensor "B" digital value and sensor "B" analog value ≥ |50| [A] Battery CAN communication active   750 [ms] continuous 2 DCY
BJB error memory status flag valid
BJB: Hybrid/EV Battery Pack Current Sensors "A" and "B" P0B13 rationality check CASE 1:     Battery CAN communication active   CASE 1: 0 DCY
deviation between measured current value of sensor 1 and measured current value of sensor 2 > |3|+ |5% of the current value of sensor 1 | [A] BJB error memory status flag valid 1.5 [s] continuous
CASE 2:         CASE 2:
deviation between measured current value of sensor 1 and measured current value of sensor 2 > |50| [A]     750 [ms] continuous
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Temperature Sensors
BJB: Temperature Sensors P0AFC circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1.5 [s] continuous 2 DCY
signal value of control board NTC temperature voltage ≤ -45 [°C] BJB error memory status flag valid
OR        
corresponding temperature of shunt board NTC sensor signal value ≤ -45 [°C]    
OR        
signal value of shunt NTC 1 temperature voltage ≤ -45 [°C]    
OR        
signal value of shunt NTC 2 temperature voltage ≤ -45 [°C]    
CASE 2: out of range high        
signal value of control board NTC temperature voltage < - 40 [°C]    
OR > -45 [°C]    
corresponding temperature of shunt board NTC sensor signal value < - 40 [°C]    
OR > -45 [°C]    
signal value of shunt NTC 1 temperature voltage < - 40 [°C]    
OR > -45 [°C]    
signal value of shunt NTC 2 temperature voltage < - 40 [°C]    
  > -45 [°C]    
BJB: Temperature Sensors P0AFC circuit low/out of range low CASE 1: circuit low     Battery CAN communication active   1.5 [s] continuous 2 DCY
signal value of control board NTC temperature voltage ≥ 135 [°C] BJB error memory status flag valid
OR        
corresponding temperature of shunt board NTC sensor signal value ≥ 135 [°C]    
OR        
signal value of shunt NTC 1 temperature voltage ≥ 135 [°C]    
OR        
signal value of shunt NTC 2 temperature voltage ≥ 135 [°C]    

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
      CASE 2: out of range low              
signal value of control board NTC temperature voltage > 125 [°C]
OR < 135 [°C]
corresponding temperature of shunt board NTC sensor signal value > 125 [°C]
OR < 135 [°C]
signal value of shunt NTC 1 temperature voltage > 125 [°C]
OR < 135 [°C]
signal value of shunt NTC 2 temperature voltage > 125 [°C]
  < 135 [°C]
BJB: Temperature Sensors P0AFC rationality check high difference between any BJB temperature and median value of all BJB temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 1 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
BJB: Temperature Sensors P0AFC rationality check low difference between any BJB temperature and median value of all BJB temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 1 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Voltage Sensors
BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor P0ABD circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 0 DCY
measured voltage > 505 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured voltage > 465 [V]    
  ≤ 505 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor P0ABC circuit low/out of range low CASE 1: circuit low     Battery CAN communication active   1 [s] continuous 0 DCY
measured voltage < 2 [V] BJB error memory status flag valid
deviation between battery voltage and voltage @ main fuse > |20| [V]    
CASE 2: out of range low        
measured voltage < 160 [V]    
  ≥ 2 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor P0ABB circuit range/performance (rationality check high) difference between battery voltage and sum of all cell voltages > 40 [V] BECM mode = AC_CHARGING   500 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR
BECM mode = PRECHARGE
BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor P0ABB circuit range/performance (rationality check low) difference between battery voltage and sum of all cell voltages < -40 [V] BECM mode = AC_CHARGING   500 [ms] continuous 0 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = HV_ON
  OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = PRECHARGE      
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Positive Terminal Sensor P0B17 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 0 DCY
measured system voltage at positive terminal > 505 [V] BJB error memory status flag valid 1 [s] continuous 0 DCY
CASE 2: out of range high          
measured system voltage at positive terminal > 465 [V]      
  ≤ 505 [V]      
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Positive Terminal Sensor P0B16 circuit low measured system voltage at positive terminal < -30 [V] (BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
  OR
BECM mode) = HV_ON
Battery CAN communication active
BJB error memory status flag valid
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Positive Terminal Sensor P0B14 circuit open deviation between measured system voltage @ positive terminal and measured voltage @ battery charger fuse > |20| [V] (BECM mode = AC_CHARGING   1 [s] continuous 0 DCY
measured system voltage at positive terminal < 10 [V]   OR
      BECM mode) = HV_ON
      Battery CAN communication active
      BJB error memory status flag valid
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Negative Terminal Sensor P0B17 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 0 DCY
measured system voltage at negative terminal > 505 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured system voltage at negative terminal > 465 [V]    
  ≤ 505 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Negative Terminal Sensor P0B16 circuit low/out of range low CASE 1: circuit low     Battery CAN communication active   1 [s] continuous 0 DCY
measured system voltage at negative terminal < -505 [V] BJB error memory status flag valid
CASE 2: out of range low        
measured system voltage at negative terminal < -465 [V]    
  ≥ -505 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" P0B15 circuit range/performance (rationality check high) difference between system voltage and battery voltage > 40 [V] BECM mode = AC_CHARGING   2 [s] continuous 0 DCY
  OR
BECM mode = HV_ON
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" P0B15 circuit range/performance (rationality check low) difference between system voltage and battery voltage < -40 [V] BECM mode = AC_CHARGING   2 [s] continuous 0 DCY
  OR
BECM mode = HV_ON
BJB: Hybrid/EV Battery Pack Voltage Sensor "C" P0B1C circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 0 DCY
measured voltage at hybrid/EV battery pack voltage sensor "C" > 505 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured voltage at hybrid/EV battery pack voltage sensor "C" > 465 [V]    
  ≤ 505 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "C" P0B1B circuit low/out of range low CASE 1: circuit low     Battery CAN communication active   1 [s] continuous 0 DCY
measured voltage at hybrid/EV battery pack voltage sensor "C" < -30 [V] BJB error memory status flag valid
CASE 2: out of range low        
measured voltage at hybrid/EV battery pack voltage sensor "C" < 140 [V]    
  ≥ -30 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "D" P0B21 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 2 DCY
measured voltage at hybrid/EV battery pack voltage sesnor "D" > 505 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured voltage at hybrid/EV battery pack voltage sesnor "D" > 465 [V]    
  ≤ 505 [V]    
BJB: Hybrid/EV Battery Pack Voltage Sensor "D" P0B20 circuit low measured voltage at hybrid/EV battery pack voltage sesnor "D" < -30 [V] Battery CAN communication active   1 [s] continuous 2 DCY
BJB error memory status flag valid
BJB: Hybrid/EV Battery Pack Voltage Sensor "D" P0B1E open circuit deviation between measured system voltage at positive terminal and measured voltage at hybrid/EV battery pack voltage sesnor "D" > 20 [V] Battery CAN communication active   1 [s] continuous 2 DCY
measured voltage at hybrid/EV battery pack voltage sesnor "D" < 10 [V] BJB error memory status flag valid
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Low Voltage Sensors
BJB: Sensor Power Supply "B" P06B5 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 2 DCY
measured voltage > 26 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured voltage > 16.2 [V]    
  ≤ 26 [V]    
BJB: Sensor Power Supply "B" P06B4 circuit low measured voltage < 7.8 [V] Battery CAN communication active   1 [s] continuous 2 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BJB error memory status flag valid      
BJB: contactor Supply Voltage Sensor P0B36 circuit high/out of range high CASE 1: circuit high     Battery CAN communication active   1 [s] continuous 0 DCY
measured voltage > 26 [V] BJB error memory status flag valid
CASE 2: out of range high        
measured voltage > 16.2 [V]    
  ≤ 26      
BJB: contactor Supply Voltage Sensor P0B35 circuit low measured voltage < 7.8 [V] Battery CAN communication active   1 [s] continuous 0 DCY
BJB error memory status flag valid
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - contactors
BJB: Hybrid/EV Battery Positive Main contactor Circuit P0AA1 stuck closed deviation between voltages before and after the main contactor on the positive HV busbar < |20| [V] (BECM mode = HV_OFF   4.5 [s] continuous 0 DCY
  OR
BECM mode) = EMERGENCY_OFF
positive main contactor is commanded open
Battery CAN communication active
BJB error memory status flag valid
BJB: Hybrid/EV Battery Positive Main contactor Circuit P0AA2 stuck open deviation between voltage before and after the main contactor on the positive HV busbar > |60| [V] (BECM mode = AC_CHARGING   1.5 [s] continuous 0 DCY
  OR
BECM mode) = HV_ON
Battery CAN communication active
BJB error memory status flag valid
BJB: Hybrid/EV Battery Negative Main contactor Circuit P0AA4 stuck closed measured voltage after the main contactor on the negative HV busbar < 20 [V] (BECM mode = HV_OFF   4.5 [s] continuous 0 DCY
modeled voltage after the main contactor on the negative HV busbar > 20 [V]   OR
      BECM mode) = EMERGENCY_OFF
      negative main contactor is commanded open
      Battery CAN communication active
      BJB error memory status flag valid
BJB: Hybrid/EV Battery Negative Main contactor Circuit P0AA5 stuck open voltage on the negative HV busbar > 60 [V] (BECM mode = AC_CHARGING   1.5 [s] continuous 0 DCY
  OR
BECM mode) = HV_ON
Battery CAN communication active
BJB error memory status flag valid
BJB: Hybrid/EV Battery Precharge contactor Circuit P0AE3 stuck open precharge energy = 0 [Ws] BECM mode = PRECHARGE   1 [s] 0 DCY
negative main contactor remains open error (P0AA5) not detected precharge time out (P0C78) detected continuous
    Battery CAN communication active  
    BJB error memory status flag valid  
BJB: Hybrid/EV Battery Positive Main contactor Control P0AD9 circuit open (functional check) contactor supply voltage > 10 [V] Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback current > 650 [mA] BJB error memory status flag valid
BJB: Hybrid/EV Battery Positive Main contactor Control P0ADC circuit high contactor driver input OFF   Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback current > 100 [mA] BJB error memory status flag valid
  < 650 [mA]    
BJB: Hybrid/EV Battery Positive Main contactor Control P0ADB circuit low contactor driver input ON [mA] Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback current < 100 BJB error memory status flag valid
BJB: Hybrid/EV Battery Negative Main contactor Control P0ADD circuit open (functional check) contactor supply voltage > 10 [V] Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback current > 650 [mA] BJB error memory status flag valid
BJB: Hybrid/EV Battery Negative Main contactor Control P0AE0 circuit high contactor driver input OFF [mA] Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback current > 100 BJB error memory status flag valid
BJB: Hybrid/EV Battery Negative Main contactor Control P0ADF circuit low contactor driver input ON [mA] Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback current < 100 BJB error memory status flag valid
BJB: Hybrid/EV Battery Precharge contactor Control P0AE7 circuit high contactor driver input OFF   Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback ON BJB error memory status flag valid
BJB: Hybrid/EV Battery Precharge contactor Control P0AE6 circuit low contactor driver input ON   Battery CAN communication active   700 [ms] continuous 0 DCY
contactor driver feedback OFF BJB error memory status flag valid
Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Protective Functions
BJB: Precharging System P0CA7 discharging current high measured shunt current < - 8 [A] BECM mode = PRECHARGE   550 [ms] continuous 0 DCY
Battery CAN communication active
BJB error memory status flag valid
BJB: Precharging System P0C78 functional check: precharge time too long deviation between battery positive voltage and system voltage > |10| [V] BECM mode = PRECHARGE   1 [s] continuous 0 DCY
Battery CAN communication active
BJB error memory status flag valid
Battery Junction Box (BJB) - Communication Monitoring
BJB: Communication U0111 lost communication with Battery Energy Contrl Module "A" CASE 1:     CASE 1:     CASE 1: 0 DCY
message time out detected Battery CAN communication active 1.5 [s] continuous
CASE 2:   BJB error memory status flag valid CASE 2:
message counter error detected CASE 2 & 3:   1.5 [s] continuous

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
        detected   Battery CAN communication active      
CASE 3: BJB error memory status flag valid  
checksum error message from BECM received CASE 3:
      600 [ms] continuous
Cell Module Controller (CMC) - Hardware/Internal Malfunctions
CMC-01: Internal Memory P0DAC internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-01 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-01: AD Converter P0DAC AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-01 error memory status flag valid
CMC-01: Internal Error P0DAC internal error in main path CASE 1:   [%] Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error detected CMC-01 error memory status flag valid 550 [ms] continuous
CASE 2:   Additionally for CASE 2:   CASE 2:
Cell voltage deviation between FET switch on and FET switch off < 2 Start up initiated 1.5 [s] once / DCY
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-02: Internal Memory P0DB0 internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-02 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-02: AD Converter P0DB0 AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-02 error memory status flag valid
CMC-02: Internal Error P0DB0 internal error in main path CASE 1:   [%] Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error detected CMC-02 error memory status flag valid 550 [ms] continuous
CASE 2:   Additionally for CASE 2:   CASE 2:
Cell voltage deviation between FET switch on and FET switch off < 2 Start up initiated 1.5 [s] once / DCY
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-03: Internal Memory P0DB4 internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-03 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-03: AD Converter P0DB4 AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-03 error memory status flag valid
CMC-03: Internal Error P0DB4 internal error in main path CASE 1: detected   Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error CMC-03 error memory status flag valid 550 [ms] continuous
CASE 2: Additionally for CASE 2:   CASE 2:

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
      Cell voltage deviation between FET switch on and FET switch off < 2 [%] Start up initiated   1.5 [s] once / DCY  
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-04: Internal Memory P0DB8 internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-04 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-04: AD Converter P0DB8 AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-04 error memory status flag valid
CMC-04: Internal Error P0DB8 internal error in main path CASE 1:   [%] Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error detected CMC-04 error memory status flag valid 550 [ms] continuous
CASE 2:   Additionally for CASE 2:   CASE 2:
Cell voltage deviation between FET switch on and FET switch off < 2 Start up initiated 1.5 [s] once / DCY
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-05: Internal Memory P0DBC internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-05 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-05: AD Converter P0DBC AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-05 error memory status flag valid
CMC-05: Internal Error P0DBC internal error in main path CASE 1:   [%] Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error detected CMC-05 error memory status flag valid 550 [ms] continuous
CASE 2:   Additionally for CASE 2:   CASE 2:
Cell voltage deviation between FET switch on and FET switch off < 2 Start up initiated 1.5 [s] once / DCY
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-06: Internal Memory P0DC0 internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-06 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-06: AD Converter P0DC0 AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-06 error memory status flag valid
CMC-06: Internal Error P0DC0 internal error in main path CASE 1: detected   Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error CMC-06 error memory status flag valid 550 [ms] continuous
CASE 2: Additionally for CASE 2:   CASE 2:

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
      Cell voltage deviation between FET switch on and FET switch off < 2 [%] Start up initiated   1.5 [s] once / DCY  
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-07: Internal Memory P0DC4 internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-07 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-07: AD Converter P0DC4 AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-07 error memory status flag valid
CMC-07: Internal Error P0DC4 internal error in main path CASE 1:   [%] Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error detected CMC-07 error memory status flag valid 550 [ms] continuous
CASE 2:   Additionally for CASE 2:   CASE 2:
Cell voltage deviation between FET switch on and FET switch off < 2 Start up initiated 1.5 [s] once / DCY
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
CMC-08: Internal Memory P0DC8 internal memory tests CASE 1: RAM/ROM error during operation     Battery CAN communication active   CASE 1: 0 DCY
RAM/ROM error detected CMC-08 error memory status flag valid 500 [ms] continuous
CASE 2: RAM/ROM error during startup       CASE 2 & 3:
RAM/ROM error detected     500 [ms] once / DCY
CASE 3: ECC logic test error        
During ECC logic test, error code detected      
CMC-08: AD Converter P0DC8 AD converter error of main path number of communication errors between microcontroller and AD converter ≥ 20 [-] Battery CAN communication active   2.5 [s] continuous 0 DCY
CMC-08 error memory status flag valid
CMC-08: Internal Error P0DC8 internal error in main path CASE 1:   [%] Battery CAN communication active   CASE 1: 0 DCY
Daisy chain stuck error detected CMC-08 error memory status flag valid 550 [ms] continuous
CASE 2: Balancing FET monitoring   Additionally for CASE 2:   CASE 2:
Cell voltage deviation between FET switch on and FET switch off < 2 Start up initiated 1.5 [s] once / DCY
CASE 3:   Additionally for CASE 3:   CASE 3:
Watchdog test error detected Shut down initiated 500 [ms] once / DCY
CASE 4:       CASE 4:
MCU malfunction detected     500 [ms] continuous
Cell Module Controller (CMC) - Temperature Sensors
Hybrid/EV Battery Temperature Sensor "A" (CMC-01) P0A9D circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-01
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "A" (CMC-01) P0A9E circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-01
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "A" (CMC-01) P0A9C circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-01 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode = LOCAL_ACTIVE      
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "A" (CMC-01) P0A9C circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-01 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "B" (CMC-02) P0AC7 circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-02
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "B" (CMC-02) P0AC8 circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-02
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "B" (CMC-02) P0AC6 circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-02 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "B" (CMC-02) P0AC6 circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-02 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "C" (CMC-03) P0ACC circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-03
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "C" (CMC-03) P0ACD circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-03
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "C" (CMC-03) P0ACB circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-03 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "C" (CMC-03) P0ACB circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-03 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
              OR      
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "D" (CMC-04) P0AEA circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-04
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "D" (CMC-04) P0AEB circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-04
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "D" (CMC-04) P0AE9 circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-04 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "D" (CMC-04) P0AE9 circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-04 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "E" (CMC-05) P0BC4 circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-05
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "E" (CMC-05) P0BC5 circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-05
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "E" (CMC-05) P0BC3 circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-05 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "E" (CMC-05) P0BC3 circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-05 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "F" (CMC-06) P0C35 circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-06
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "F" (CMC-06) P0C36 circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-06
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
Hybrid/EV Battery Temperature Sensor "F" (CMC-06) P0C34 circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-06 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "F" (CMC-06) P0C34 circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-06 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "G" (CMC-07) P0C7E circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-07
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "G" (CMC-07) P0C7F circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-07
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "G" (CMC-07) P0C7D circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-07 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "G" (CMC-07) P0C7D circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-07 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Hybrid/EV Battery Temperature Sensor "H" (CMC-08) P0C83 circuit low (temperature out of range high) measured cell temperature (from internal cell temperature sensor 1) > 85 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-08
measured cell temperature (from internal cell temperature sensor 2) > 85 [°C]  
Hybrid/EV Battery Temperature Sensor "H" (CMC-08) P0C84 circuit high (temperature out of range low) measured cell temperature (from internal cell temperature sensor 1) < -40 [°C] Battery CAN communication active   1.5 [s] continuous 0 DCY
OR     No internal communication error in CMC-08
measured cell temperature (from internal cell temperature sensor 2) < -40 [°C]  
Hybrid/EV Battery Temperature Sensor "H" (CMC-08) P0C82 circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-08 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode) = RUN_ON      
Hybrid/EV Battery Temperature Sensor "H" (CMC-08) P0C82 circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-08 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status time calculated [min] 2.7 [s] continuous 2 DCY
HV off time ≥ 360...720
(BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode = INIT
  OR
BECM mode = LOCAL_ACTIVE
  OR
BECM mode) = RUN_ON
Cell Module Controller (CMC) - Cell Voltage Sensors
Hybrid/EV Battery Voltage Sensor "A" (CMC-01) P0B3E circuit high measured cell voltages in CMC-01 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-01 error memory status flag valid
No internal communication error in CMC-01  
Hybrid/EV Battery Voltage Sensor "A" (CMC-01) P0B3D circuit low measured cell voltages in CMC-01 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-01 error memory status flag valid
No internal communication error in CMC-01  
Hybrid/EV Battery Voltage Sensor "A" (CMC-01) P0B3B open circuit measured cell voltages of broken line and the next higher line in CMC-01 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-01 error memory status flag valid
No internal communication error in CMC-01  
Hybrid/EV Battery Voltage Sensor "A" (CMC-01) P0B3C circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-01 and ASIC voltage of CMC-01 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-01 and mean value (ASIC voltage of CMC-01 divided by number of cells in CMC-01) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "A" (CMC-01) P0B3C circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-01 and ASIC voltage of CMC-01 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-01 and mean value (ASIC voltage of CMC-01 divided by number of cells in CMC-01) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "B" (CMC-02) P0B43 circuit high measured cell voltages in CMC-02 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-02 error memory status flag valid
No internal communication error in CMC-02  
Hybrid/EV Battery Voltage Sensor "B" (CMC-02) P0B42 circuit low measured cell voltages in CMC-02 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-02 error memory status flag valid
No internal communication error in CMC-02  
Hybrid/EV Battery Voltage Sensor "B" (CMC-02) P0B40 open circuit measured cell voltages of broken line and the next higher line in CMC-02 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-02 error memory status flag valid
No internal communication error in CMC-02  
Hybrid/EV Battery Voltage Sensor "B" (CMC-02) P0B41 circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-02 and ASIC voltage of CMC-02 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-02 and mean value (ASIC voltage of CMC-02 divided by number of cells in CMC-02) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "B" (CMC-02) P0B41 circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-02 and ASIC voltage of CMC-02 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-02 and mean value (ASIC voltage of CMC-02 divided by number of cells in CMC-02) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "C" (CMC-03) P0B48 circuit high measured cell voltages in CMC-03 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-03 error memory status flag valid
No internal communication error in CMC-03  
Hybrid/EV Battery Voltage Sensor "C" (CMC-03) P0B47 circuit low measured cell voltages in CMC-03 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-03 error memory status flag valid
No internal communication error in CMC-03  
Hybrid/EV Battery Voltage Sensor "C" (CMC-03) P0B45 open circuit measured cell voltages of broken line and the next higher line in CMC-03 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            CMC-03 error memory status flag valid      
No internal communication error in CMC-03
Hybrid/EV Battery Voltage Sensor "C" (CMC-03) P0B46 circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-03 and ASIC voltage of CMC-03 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-03 and mean value (ASIC voltage of CMC-03 divided by number of cells in CMC-03) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "C" (CMC-03) P0B46 circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-03 and ASIC voltage of CMC-03 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-03 and mean value (ASIC voltage of CMC-03 divided by number of cells in CMC-03) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "D" (CMC-04) P0B4D circuit high measured cell voltages in CMC-04 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-04 error memory status flag valid
No internal communication error in CMC-04  
Hybrid/EV Battery Voltage Sensor "D" (CMC-04) P0B4C circuit low measured cell voltages in CMC-04 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-04 error memory status flag valid
No internal communication error in CMC-04  
Hybrid/EV Battery Voltage Sensor "D" (CMC-04) P0B4A open circuit measured cell voltages of broken line and the next higher line in CMC-04 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-04 error memory status flag valid
No internal communication error in CMC-04  
Hybrid/EV Battery Voltage Sensor "D" (CMC-04) P0B4B circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-04 and ASIC voltage of CMC-04 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-04 and mean value (ASIC voltage of CMC-04 divided by number of cells in CMC-04) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "D" (CMC-04) P0B4B circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-04 and ASIC voltage of CMC-04 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-04 and mean value (ASIC voltage of CMC-04 divided by number of cells in CMC-04) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "E" (CMC-05) P0B52 circuit high measured cell voltages in CMC-05 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-05 error memory status flag valid
No internal communication error in CMC-05  
Hybrid/EV Battery Voltage Sensor "E" (CMC-05) P0B51 circuit low measured cell voltages in CMC-05 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-05 error memory status flag valid
No internal communication error in CMC-05  
Hybrid/EV Battery Voltage Sensor "E" (CMC-05) P0B4F open circuit measured cell voltages of broken line and the next higher line in CMC-05 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-05 error memory status flag valid
No internal communication error in CMC-05  
Hybrid/EV Battery Voltage Sensor "E" (CMC-05) P0B50 circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-05 and ASIC voltage of CMC-05 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-05 and mean value (ASIC voltage of CMC-05 divided by number of cells in CMC-05) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "E" (CMC-05) P0B50 circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-05 and ASIC voltage of CMC-05 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-05 and mean value (ASIC voltage of CMC-05 divided by number of cells in CMC-05) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "F" (CMC-06) P0B57 circuit high measured cell voltages in CMC-06 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-06 error memory status flag valid
No internal communication error in CMC-06  
Hybrid/EV Battery Voltage Sensor "F" (CMC-06) P0B56 circuit low measured cell voltages in CMC-06 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            CMC-06 error memory status flag valid      
No internal communication error in CMC-06
Hybrid/EV Battery Voltage Sensor "F" (CMC-06) P0B54 open circuit measured cell voltages of broken line and the next higher line in CMC-06 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-06 error memory status flag valid
No internal communication error in CMC-06  
Hybrid/EV Battery Voltage Sensor "F" (CMC-06) P0B55 circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-06 and ASIC voltage of CMC-06 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-06 and mean value (ASIC voltage of CMC-06 divided by number of cells in CMC-06) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "F" (CMC-06) P0B55 circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-06 and ASIC voltage of CMC-06 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-06 and mean value (ASIC voltage of CMC-06 divided by number of cells in CMC-06) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "G" (CMC-07) P0B5C circuit high measured cell voltages in CMC-07 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-07 error memory status flag valid
No internal communication error in CMC-07  
Hybrid/EV Battery Voltage Sensor "G" (CMC-07) P0B5B circuit low measured cell voltages in CMC-07 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-07 error memory status flag valid
No internal communication error in CMC-07  
Hybrid/EV Battery Voltage Sensor "G" (CMC-07) P0B59 open circuit measured cell voltages of broken line and the next higher line in CMC-07 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-07 error memory status flag valid
No internal communication error in CMC-07  
Hybrid/EV Battery Voltage Sensor "G" (CMC-07) P0B5A circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-07 and ASIC voltage of CMC-07 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-07 and mean value (ASIC voltage of CMC-07 divided by number of cells in CMC-07) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "G" (CMC-07) P0B5A circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-07 and ASIC voltage of CMC-07 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-07 and mean value (ASIC voltage of CMC-07 divided by number of cells in CMC-07) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "H" (CMC-08) P0B61 circuit high measured cell voltages in CMC-08 > 4.5 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-08 error memory status flag valid
No internal communication error in CMC-08  
Hybrid/EV Battery Voltage Sensor "H" (CMC-08) P0B60 circuit low measured cell voltages in CMC-08 < 1 [V] Battery CAN communication active   1 [s] continuous 0 DCY
CMC-08 error memory status flag valid
No internal communication error in CMC-08  
Hybrid/EV Battery Voltage Sensor "H" (CMC-08) P0B5E open circuit measured cell voltages of broken line and the next higher line in CMC-08 = 5.6 [V] Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-08 error memory status flag valid
No internal communication error in CMC-08  
Hybrid/EV Battery Voltage Sensor "H" (CMC-08) P0B5F circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-08 and ASIC voltage of CMC-08 > 1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-08 and mean value (ASIC voltage of CMC-08 divided by number of cells in CMC-08) > 1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Hybrid/EV Battery Voltage Sensor "H" (CMC-08) P0B5F circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-08 and ASIC voltage of CMC-08 < -1 [V] BECM mode = AC_CHARGING   500 [ms] continuous 2 DCY
OR       OR
difference between any cell voltage in CMC-08 and mean value (ASIC voltage of CMC-08 divided by number of cells in CMC-08) < -1 [V] BECM mode = EMERGENCY_OFF
        OR
      BECM mode = HV_OFF
        OR
      BECM mode = HV_ON
Cell Module Controller (CMC) - Communication Monitoring

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
CMC-01: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-01 error memory status flag valid
CMC-02: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-02 error memory status flag valid
CMC-03: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-03 error memory status flag valid
CMC-04: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-04 error memory status flag valid
CMC-05: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-05 error memory status flag valid
CMC-06: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-06 error memory status flag valid
CMC-07: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-07 error memory status flag valid
CMC-08: Communication U0111 lost communication with Battery Energy Control Module "A" message time out detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-08 error memory status flag valid
CMC-01: Communication P0DAF Hybrid/EV Battery Cell Balancing Circuit "A" Bus-Off error of CMC-01 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-01 error memory status flag valid
CMC-02: Communication P0DB3 Hybrid/EV Battery Cell Balancing Circuit "B" Bus-Off error of CMC-02 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-02 error memory status flag valid
CMC-03: Communication P0DB7 Hybrid/EV Battery Cell Balancing Circuit "C" Bus-Off error of CMC-03 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-03 error memory status flag valid
CMC-04: Communication P0DBB Hybrid/EV Battery Cell Balancing Circuit "D" Bus-Off error of CMC-04 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-04 error memory status flag valid
CMC-05: Communication P0DBF Hybrid/EV Battery Cell Balancing Circuit "E" Bus-Off error of CMC-05 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-05 error memory status flag valid
CMC-06: Communication P0DC3 Hybrid/EV Battery Cell Balancing Circuit "F" Bus-Off error of CMC-06 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-06 error memory status flag valid
CMC-07: Communication P0DC7 Hybrid/EV Battery Cell Balancing Circuit "G" Bus-Off error of CMC-07 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-07 error memory status flag valid
CMC-08: Communication P0DCB Hybrid/EV Battery Cell Balancing Circuit "H" Bus-Off error of CMC-08 CAN controller detected   Battery CAN communication active   1.5 [s] continuous 0 DCY
CMC-08 error memory status flag valid
Battery Energy Control Module (BECM) - Performance Monitoring
BECM: State of charge window monitoring P057F state of charge window monitoring as per CCR J1968.2 CASE 1: first monitoring cycle after changing from HV_OFF to HV_ON and driving cycle identified     BECM mode = HV_ON   CASE 1: 2 DCY
State of charge starts above the upper limit and stays outside > 95 [%] 650 [s] once / DCY
OR      
State of charge starts below the lower limit and stays outside < 15 [%] CASE 2:
CASE 2: second and following monitoring cycles     5 [s] continuous
State of charge starts above the upper limit and stays outside > 95 [%]  
OR      
State of charge starts below the lower limit and stays outside < 15 [%]  
BECM: Performance monitoring based on resistance P0A80 performance check as per CCR J1968.2 (based on resistance) on battery level ratio between calculated battery resistance and Begin-Of-Life (BOL) resistance > 2   average cell temperatures < 50 [°C] 500 [s] continuous 2 DCY
  > -5 [°C]
deviation between maximum and minimum cell temperature < 10 [°C]
battery current for calculation < 0 [A]
battery current < -20 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.1 [-]
gradient of battery current < -1 [A/100ms]
time after ECU startup ≥ 1.5 [s]
CMC-01: Performance Check based on capacity P0A7F performance check as per CCR J1968.2 (based on capacity) for CMC01 calculated capacity for CMC01 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-02: Performance Check based on capacity P0EDD performance check as per CCR J1968.2 (based on capacity) for CMC02 calculated capacity for CMC02 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            runtime/EEPROM data are valid [-]    
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-03: Performance Check based on capacity P0EDE performance check as per CCR J1968.2 (based on capacity) for CMC03 calculated capacity for CMC03 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-04: Performance Check based on capacity P0EDF performance check as per CCR J1968.2 (based on capacity) for CMC04 calculated capacity for CMC04 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-05: Performance Check based on capacity P0EE0 performance check as per CCR J1968.2 (based on capacity) for CMC05 calculated capacity for CMC05 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-06: Performance Check based on capacity P0EE1 performance check as per CCR J1968.2 (based on capacity) for CMC06 calculated capacity for CMC06 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-07: Performance Check based on capacity P2CCC performance check as per CCR J1968.2 (based on capacity) for CMC07 calculated capacity for CMC07 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-08: Performance Check based on capacity P2CCD performance check as per CCR J1968.2 (based on capacity) for CMC08 calculated capacity for CMC08 < 27.636 [Ah] OCV-conditions fulfilled:     500 [ms] continuous 2 DCY
battery current < 1...3 [A]
for time = 7, 200...600 [s]
runtime/EEPROM data are valid [-]
difference of SOC between current and ultimate OCV measurement ≥ 60 [%]
time between current and ultimate OCV measurement < 4 [days]
max. worst CASE Ah-accounting error < 2 [%]
CMC-01: Performance Check P0A7F performance check as per CCR J1968.2 (based on resistance) for CMC01 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-02: Performance Check P0EDD performance check as per CCR J1968.2 (based on resistance) for CMC02 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-03: Performance Check P0EDE performance check as per CCR J1968.2 (based on resistance) for CMC03 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
              > -5 [°C]    
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-04: Performance Check P0EDF performance check as per CCR J1968.2 (based on resistance) for CMC04 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-05: Performance Check P0EE0 performance check as per CCR J1968.2 (based on resistance) for CMC05 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-06: Performance Check P0EE1 performance check as per CCR J1968.2 (based on resistance) for CMC06 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-07: Performance Check P2CCC performance check as per CCR J1968.2 (based on resistance) for CMC07 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-08: Performance Check P2CCD performance check as per CCR J1968.2 (based on resistance) for CMC08 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2   battery current for cell selection < -100 [A] 500 [s] continuous 2 DCY
average cell temperatures < 50 [°C]
  > -5 [°C]
deviation between max. and min. cell temperature < 5 [°C]
battery current for calculation < 0 [A]
count of calculation ratios = 100 [-]
difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set ≤ 0.15 [-]
time after cell selection ≥ 1.5 [s]
time after ECU startup ≥ 1.5 [s]
CMC-01: Balancing Check P0DAC balancing check per CCR J1968.2 for CMC01 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-02: Balancing Check P0DB0 balancing check per CCR J1968.2 for CMC02 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-03: Balancing Check P0DB4 balancing check per CCR J1968.2 for CMC03 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
OR

Table continues below

Component/System Fault Code (SAE-Code) Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illumination
            BECM mode) = LOCAL_ACTIVE      
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-04: Balancing Check P0DB8 balancing check per CCR J1968.2 for CMC04 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-05: Balancing Check P0DBC balancing check per CCR J1968.2 for CMC05 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-06: Balancing Check P0DC0 balancing check per CCR J1968.2 for CMC06 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-07: Balancing Check P0DC4 balancing check per CCR J1968.2 for CMC07 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
CMC-08: Balancing Check P0DC8 balancing check per CCR J1968.2 for CMC08 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 4 [Ah] (BECM mode = HV_OFF   500 [ms] continuous 2 DCY
  OR  
BECM mode) = LOCAL_ACTIVE  
absolute battery current < 5 [A]
OCV recovery time ≥ 11, 000...330 [s]
cell state of charge > 30 [%]
Battery Charger Control Module (BCCM) - Component errors
BCCM: Invalid Diagnostic Information U113A error memory status flag check BCCM error memory status flag not valid   (BECM mode = AC_CHARGING   2.5 [s] continuous 2 DCY
  OR
BECM mode = EMERGENCY_OFF
  OR
BECM mode = HV_OFF
  OR
BECM mode) = HV_ON
Hybrid CAN communication active