Battery Energy Control Module --, 2021 MY
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Battery Energy Control Module (BECM) - Hardware/Internal Malfunctions | ||||||||||
| BECM: Performance (Self Test) | P0A1F | internal hardware check | CPU test | failed | 5 [ms] On Mode Change (except to EMERGENCY_OFF or LOCAL_ACTIVE) | 0 DCY | ||||
| OR | ||||||||||
| RAM test | failed | |||||||||
| OR | ||||||||||
| ROM test | failed | |||||||||
| BECM: Internal Control Module | P0604 | Random Access Memory (RAM) check | secured internal data exchange | failed | 5 [ms] continuous | 0 DCY | ||||
| BECM: Internal Control Module | P062F | EEPROM check | memory checksum error | detected | 1 [s] multiple | 0 DCY | ||||
| BECM: Hybrid CAN Controller | P163E | CAN RAM check | read/write check in hybrid CAN-RAM | failed | BECM mode | = INIT | 5 [ms] once / DCY | 0 DCY | ||
| BECM: Battery CAN Controller | P163E | CAN RAM check | read/write check in battery CAN-RAM | failed | BECM mode | = INIT | 5 [ms] once / DCY | 0 DCY | ||
| BECM: Control Module Processor | P0606 | watchdog reset | watchdog reset | occurred | 5 [ms] continuous | 0 DCY | ||||
| BECM: Control Module | U3001 | improper shutdown performance | incorrect BECM postrun execution (aborted or not started) | 5 times in a row | BECM mode | = INIT | 150 [ms] once / DCY | 0 DCY | ||
| at least one OBD-relevant monitoring | failed and pending | |||||||||
| BECM: Battery Monitor Module - Daisy Chain Input | P058D | voltage monitoring performance (short to battery) | CASE 1: | (BECM mode | = AC_CHARGING | 2 [s] continuous | 0 DCY | |||
| ratio of BECM Daisy Chain input voltage to battery voltage | > 0.9 | [-] | OR | |||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| CASE 2: | OR | |||||||||
| BECM Daisy Chain input voltage | > 4 | [V] | BECM mode | = HV_OFF | ||||||
| Critical over voltage/under voltage condition of any cell voltage | reported | OR | ||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| Battery CAN communication | active | |||||||||
| error memory status flags of all CMCs | valid | |||||||||
| BECM: Battery Monitor Module - Daisy Chain Input | P058D | voltage monitoring performance (short to ground) | BECM Daisy Chain input voltage | < 4 | [V] | (BECM mode | = AC_CHARGING | 2 [s] continuous | 0 DCY | |
| No Critical over voltage/under voltage condition of any cell voltage | reported | OR | ||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| Battery CAN communication | active | |||||||||
| error memory status flags of all CMCs | valid | |||||||||
| BECM: Battery Monitor Module - Daisy Chain Output | P058D | voltage monitoring performance (short to battery) | BECM Daisy Chain output voltage | > 4 | [V] | (BECM mode | = AC_CHARGING | 5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| BECM Daisy Chain output target value | = 0 | |||||||||
| BECM: Battery Monitor Module - Daisy Chain Output | P058D | voltage monitoring performance (short to ground) | BECM Daisy Chain output voltage | < 4 | [V] | (BECM mode | = AC_CHARGING | 5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| BECM Daisy Chain output target value | = 1 | |||||||||
| BECM: Internal Control Module - Hardware Disable Output | P0E2D | hybrid/EV battery monitor performance (short to battery) | Hardware-Disable output voltage | > 10 | [V] | (BECM mode | = AC_CHARGING | 5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| BECM HW Disable output target value | = 0 | |||||||||
| BECM: Internal Control Module - Hardware Disable Output | P0E2D | hybrid/EV battery monitor performance (short to ground) | Hardware-Disable output voltage | < 4 | [V] | (BECM mode | = AC_CHARGING | 5 [s] continuous | 0 DCY | |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| BECM HW Disable output target value | = 1 | |||||||||
| BECM: High-Voltage System Interlock | P0A0D | circuit "A" high (short to battery) | voltage drop across shunt | > 5 | [V] | 500 [ms] continuous | 0 DCY | |||
| BECM: High-Voltage System Interlock | P0A0C | circuit "A" low (short to ground) | voltage drop across shunt | < 0.2 | [V] | 500 [ms] continuous | 0 DCY | |||
| BECM: High-Voltage System Interlock | P0A0A | HV interlock implausible | HV interlock loop current | < 8 | [mA] | 100 [ms] continuous | 0 DCY | |||
| OR | ||||||||||
| HV interlock loop current | > 12 | [mA] | ||||||||
| BECM: High-Voltage System Interlock | P0A0B | performance (internal circuit) | Value measured by HV interlock ADC with input signal set to ground level (0 V) | > 51.57 | [mV] | (BECM mode | = AC_CHARGING | 500 [ms] continuous | 0 DCY | |
| OR | OR | |||||||||
| Value measured by HV interlock ADC with input signal set to reference voltage (3.3 V) | <3248.43 | [mV] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | OR | |||||||||
| HV Interlock ADC values | not received | BECM mode | = HV_OFF | |||||||
| for time | 10 | [ms] | OR | |||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode) | = INIT | |||||||||
| BECM: Control Module Power Off Timer | P262B | plausibility check A - MAX check (rationality check high) | CASE 1: | BECM mode | = RUN_ON | [s] | 0 [s] once / DCY | 2 DCY | ||
| 0.06 * actual postrun timer | ≤ 1 | [s] | HV Supply | switched off | ||||||
| AND | for time | ≥ 5 | ||||||||
| actual postrun timer - HV off hardware timer value | ≥ 1 | [s] | ||||||||
| CASE 2: | ||||||||||
| 0.06 * actual postrun timer | > 1 | [s] | ||||||||
| AND | ||||||||||
| ratio of HV off hardware timer value to actual postrun time | ≥ 1.06 | [-] | ||||||||
| BECM: Control Module Power Off Timer | P262B | plausibility check A - MIN check (rationality check low) | CASE 1: | BECM mode | = RUN_ON | [s] | 0 [s] once / DCY | 2 DCY | ||
| 0.06 * actual postrun timer | ≤ 1 | [s] | HV Supply | switched off | ||||||
| AND | for time | ≥ 5 | ||||||||
| HV off hardware timer value - actual postrun timer | ≥ 1 | [s] | ||||||||
| CASE 2: | ||||||||||
| 0.06 * actual postrun timer | > 1 | [s] | ||||||||
| AND | ||||||||||
| ratio of HV off hardware timer value to actual postrun time | ≤ 0.94 | [-] | ||||||||
| BECM: Control Module Power Off Timer | P262B | plausibility check B - MIN check (rationality check low) | ratio of HV off hardware timer value to last stored internal postrun time | ≤ 0.94 | [-] | BECM mode | = INIT | 0 [s] once / DCY | 2 DCY | |
| BECM: Control Module Power Off Timer | P262B | plausibility check C (internal circuit) | Response from HV Off Hardware Timer circuit during initialization | not received | 40 [ms] once / DCY | 2 DCY | ||||
| OR | ||||||||||
| Response from HV Off Hardware Timer circuit | invalid | |||||||||
| Battery Energy Control Module (BECM) - Software Version / Calibration Monitoring | ||||||||||
| BECM: Dataset Implausible | B2012 | compatibility check | dataset and hardware/software | not compatible | BECM mode | = INIT | 5 [ms] once / DCY | 0 DCY | ||
| BECM: Dataset Invalid | B2005 | dataset check | dataset | invalid | BECM mode | = INIT | 5 [ms] once / DCY | 0 DCY | ||
| BECM: Production Mode | P0610 | vehicle in production mode | production mode | active | for activation: | < 100 | [km] | 5 [s] once / DCY | 0 DCY | |
| max mileage since initial vehicle start-up | ||||||||||
| BECM: OBD Settings Incompatible | P064F | compatibility check | internal OBD settings and vehicle OBD settings | not compatible | valid message containing vehicle OBD settings | received | 2.9 [s] continuous | 0 DCY | ||
| Battery Energy Control Module (BECM) - Cooling System | ||||||||||
| Hybrid/EV Battery Pack Coolant Pump Supply Voltage | P0C4D | circuit high | supply voltage @ coolant pump | > 0.4 | [V] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Pack Coolant Pump Supply Voltage | P0C4C | circuit low | ratio of supply voltage @ coolant pump to 12 V supply voltage | < 0.9 | [-] | coolant pump | switched on | 5 [s] continuous | 2 DCY | |
| AND | ||||||||||
| BECM mode | = AC_CHARGING | |||||||||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Hybrid/EV Battery Pack Coolant Pump "A" Control | P0C49 | circuit high | time duration of high signal sent by pump | ≥ 10 | [s] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Pack Coolant Pump "A" Control | P0C48 | circuit low | time duration of ground signal sent by pump | ≥ 2 | [s] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Pack Coolant Pump "A" Control | P0C47 | circuit open (functional check: time out) | alive signal (PWM signal) | missing | 39.5 [s] continuous | 2 DCY | ||||
| Hybrid/EV Battery Pack Coolant Pump "A" | P0C4A | performance (functional check: dry run) | time duration of ground signal sent by pump | > 900 | [ms] | coolant pump | commanded on | % | 7.2 [s] continuous | 2 DCY |
| <1100 | [ms] | pump time out monitoring | passed | |||||||
| AND | PWM duty cycle | > 85 | ||||||||
| pause time between ground signal sent by pump | > 900 | [ms] | ||||||||
| <1100 | [ms] | |||||||||
| Hybrid/EV Battery Pack Coolant Pump | P0CFF | functional check: stuck/stalled | time duration of ground signal sent by pump | >1400 | [ms] | coolant pump | commanded on | % | 21 [s] continuous | 2 DCY |
| < 1600 | [ms] | pump time out monitoring | passed | |||||||
| AND | PWM duty cycle | > 25 | ||||||||
| pause time between ground signal sent by pump | > 900 | [ms] | ||||||||
| <1100 | [ms] | |||||||||
| Hybrid/EV Battery Pack Coolant Pump "A" | P0C4A | performance (functional check: overheating) | time duration of ground signal sent by pump | >1900 | [ms] | coolant pump | commanded on | 8.2 [s] continuous | 2 DCY | |
| AND | < 2100 | [ms] | pump time out monitoring | passed | ||||||
| pause time between ground signal sent by pump | > 900 | [ms] | ||||||||
| <1100 | [ms] | |||||||||
| Battery Energy Control Module (BECM) - Cooling Temperature Sensors | ||||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C45 | circuit high (short to battery) | signal value of temperature voltage @ HV battery inlet | > 3248.44 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C44 | circuit low (short to ground) | signal value of temperature voltage @ HV battery inlet | < 48.34 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C42 | open circuit | signal value of temperature voltage @ HV battery inlet | > 3125.98 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| < 3158.20 | [mV] | OR | ||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C44 | circuit low (out of range low) | signal value of temperature voltage @ HV battery inlet | > 48.34 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| < 325.48 | [mV] | OR | ||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C45 | circuit high (out of range high) | signal value of temperature voltage @ HV battery inlet | > 3019.63 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| < 3125.98 | [mV] | OR | ||||||||
| OR | BECM mode | = EMERGENCY_OFF | ||||||||
| signal value of temperature voltage @ HV battery inlet | > 3158.20 | [mV] | OR | |||||||
| < 3248.44 | [mV] | BECM mode | = HV_OFF | |||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C43 | range/performance (rationality high) | difference between coolant temperature @ HV battery inlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature | ≥ 15...21 | [°C] | HV off time calculations status | time calculated | [min] | 1.5 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Coolant Temperature Sensor at HV Battery Inlet | P0C43 | range/performance (rationality low) | difference between coolant temperature @ HV battery inlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature | ≤ -15...-21 | [°C] | HV off time calculations status | time calculated | [min] | 1.5 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD8 | circuit high (short to battery) | signal value of temperature voltage @ HV battery outlet | > 3248.44 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD7 | circuit low (short to ground) | signal value of temperature voltage @ HV battery outlet | < 48.34 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD5 | open circuit | signal value of temperature voltage @ HV battery outlet | > 3125.98 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| < 3158.20 | [mV] | OR | ||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD7 | circuit low (out of range low) | signal value of temperature voltage @ HV battery outlet | > 48.34 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| < 325.48 | [mV] | OR | ||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | OR | |||||||||
| = INIT | ||||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD8 | circuit high (out of range high) | signal value of temperature voltage @ HV battery outlet | > 3019.63 | [mV] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| < 3125.98 | [mV] | OR | ||||||||
| OR | BECM mode | = EMERGENCY_OFF | ||||||||
| signal value of temperature voltage @ HV battery outlet | > 3158.20 | [mV] | OR | |||||||
| < 3248.44 | [mV] | BECM mode | = HV_OFF | |||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD6 | range/performance (rationality high) | difference between coolant temperature @ HV battery outlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature | ≥ 15...21 | [°C] | HV off time calculations status | time calculated | [min] | 2 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Coolant Temperature Sensor at HV Battery Outlet | P0CD6 | range/performance (rationality low) | difference between coolant temperature @ HV battery outlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature | ≤ -15...-21 | [°C] | HV off time calculations status | time calculated | [min] | 2 [s]continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Coolant Temperature at Chiller | P0CEF | range/performance (rationality high) | difference between pump coolant temperature and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature | ≥ 15...21 | [°C] | HV off time calculations status | time calculated | [min] | 2.2 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Coolant Temperature at Chiller | P0CEF | range/performance (rationality low) | difference between pump coolant temperature and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature | ≤ -15...-21 | [°C] | HV off time calculations status | time calculated | [min] | 2.2 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Battery Energy Control Module (BECM) - High-Voltage System Activation | ||||||||||
| BJB State Monitoring | P33F0 | change to HV_ON fails | BJB mode | != HV_ON | BJB Target mode | = HV_ON | 1 [s] continuous | 0 DCY | ||
| BJB State Monitoring | P33F0 | change to AC_CHARGING fails | BJB mode | != AC_CHARGING | BJB Target mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | ||
| BJB State Monitoring | P33F0 | emergency shutoff | BJB mode | = EMERGENCY_OFF | BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = INIT | |||||||||
| Battery Energy Control Module (BECM) - Protective Functions | ||||||||||
| BECM: Hybrid/EV Battery Charging Current | P0CA6 | charging current high | measured HV battery charge current | > 0...240 | [A] | BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| BECM: Hybrid/EV Battery Discharging Current | P0CA7 | discharging current high | measured HV battery discharge current | > 0...400 | [A] | BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| BECM: Hybrid/EV Battery System Voltage | P0AFB | system voltage high | pack voltage signal | > 448 | [V] | BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| BECM: Hybrid/EV Battery System Voltage | P0AFA | system voltage low | pack voltage signal | < 187 | [V] | BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-01: Hybrid/EV Battery Interface Control Module "A" | P0B26 | cell voltage high | any cell voltage signal within CMC-01 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-01: Hybrid/EV Battery Interface Control Module "A" | P0B25 | cell voltage low | any cell voltage signal within CMC-01 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-01: Hybrid/EV Battery Interface Control Module "A" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-01 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-02: Hybrid/EV Battery Interface Control Module "B" | P0B26 | cell voltage high | any cell voltage signal within CMC-02 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-02: Hybrid/EV Battery Interface Control Module "B" | P0B25 | cell voltage low | any cell voltage signal within CMC-02 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-02: Hybrid/EV Battery Interface Control Module "B" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-02 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-02: Hybrid/EV Battery Interface Control Module "C" | P0B26 | cell voltage high | any cell voltage signal within CMC-03 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-03: Hybrid/EV Battery Interface Control Module "C" | P0B25 | cell voltage low | any cell voltage signal within CMC-03 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-03: Hybrid/EV Battery Interface Control Module "C" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-03 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-04: Hybrid/EV Battery Interface Control Module "D" | P0B26 | cell voltage high | any cell voltage signal within CMC-04 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-04: Hybrid/EV Battery Interface Control Module "D" | P0B25 | cell voltage low | any cell voltage signal within CMC-04 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-04: Hybrid/EV Battery Interface Control Module "D" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-04 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-05: Hybrid/EV Battery Interface Control Module "E" | P0B26 | cell voltage high | any cell voltage signal within CMC-05 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-05: Hybrid/EV Battery Interface Control Module "E" | P0B25 | cell voltage low | any cell voltage signal within CMC-05 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-05: Hybrid/EV Battery Interface Control Module "E" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-05 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-06: Hybrid/EV Battery Interface Control Module "F" | P0B26 | cell voltage high | any cell voltage signal within CMC-06 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-06: Hybrid/EV Battery Interface Control Module "F" | P0B25 | cell voltage low | any cell voltage signal within CMC-06 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-06: Hybrid/EV Battery Interface Control Module "F" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-06 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-07: Hybrid/EV Battery Interface Control Module "G" | P0B26 | cell voltage high | any cell voltage signal within CMC-07 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-07: Hybrid/EV Battery Interface Control Module "G" | P0B25 | cell voltage low | any cell voltage signal within CMC-07 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-07: Hybrid/EV Battery Interface Control Module "G" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-07 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-08: Hybrid/EV Battery Interface Control Module "H" | P0B26 | cell voltage high | any cell voltage signal within CMC-08 | > 4.3 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-08: Hybrid/EV Battery Interface Control Module "H" | P0B25 | cell voltage low | any cell voltage signal within CMC-08 | < 1.8...2.0 | [V] | BECM mode | = AC_CHARGING | 100 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| CMC-08: Hybrid/EV Battery Interface Control Module "H" | P0BBD | cell voltage rationality check | difference between maximum cell voltage and minimum cell voltage within CMC-08 | > 0.25 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| BECM: Daisy Chain Redundant Safety Shutdown | P0AF8 | redundant safety shutdown due to cell overvoltage/undervoltage | BECM Daisy Chain input | < 4 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| BJB: Main Fuse | P0A95 | rationality check | deviation between battery voltage and voltage at main fuse | > |20| | [V] | BECM mode | = AC_CHARGING | 5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| BJB: Battery Charger Fuse | P0E2E | rationality check | deviation between system voltage and voltage at battery charger fuse | > |20| | [V] | BECM mode | = AC_CHARGING | 5 [s] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| BECM: Vehicle System - 12 Volt Supply Voltage | P0563 | system voltage high | power supply voltage | > 17 | [V] | 9 [s] continuous | 0 DCY | |||
| BECM: Vehicle System - 12 Volt Supply Voltage | U1401 | system voltage high | power supply voltage | > 17 | [V] | 10 [ms] continuous | 0 DCY | |||
| BECM: Vehicle System - 12 Volt Supply Voltage | P0562 | system voltage low | power supply voltage | < 8 | [V] | 9 [s] continuous | 0 DCY | |||
| BECM: Vehicle System - 12 Volt Supply Voltage | U1400 | system voltage low | power supply voltage | < 8 | [V] | 10 [ms] continuous | 0 DCY | |||
| BECM: Vehicle System - 12 Volt Supply Voltage | U1400 | system voltage pre-low | power supply voltage | < 9 | [V] | 10 [ms] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM: Crash Detection | P1609 | crash shut-off was triggered | crash | detected | System | active | 0 [ms] continuous | 0 DCY | ||
| Battery Energy Control Module (BECM) - CAN Communication Monitoring | ||||||||||
| Hybrid CAN | U0028 | vehicle communication bus A | CAN controller enters "BUS OFF" state | 3 times in a row | time after ECU wake up | > 500 | [ms] | 450 [ms] continuous | 0 DCY | |
| Hybrid CAN | U0029 | vehicle communication bus A performance | CAN messages | not received | time after ECU wake up | > 500 | [ms] | 450 [ms] continuous | 0 DCY | |
| Hybrid CAN: Engine Control Module (ECM) | U0100 | lost communication with ECM/PCM "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| FlexRay | active | |||||||||
| Hybrid CAN: Engine Control Module (ECM) | U0100 | lost communication with ECM/PCM "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 800 [ms] continuous | 0 DCY | |
| FlexRay | active | |||||||||
| Hybrid CAN: Engine Control Module (ECM) | U0100 | lost communication with ECM/PCM "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 2 DCY | |
| FlexRay | active | |||||||||
| Hybrid CAN: Engine Control Module (ECM) | U0401 | invalid data received from ECM/PCM "A" | message counter error | detected | time after ECU wake up | > 500 | [ms] | 8 [s] continuous | 0 DCY | |
| valid message from ECM | received | |||||||||
| Hybrid CAN: Engine Control Module (ECM) | U0401 | invalid data received from ECM/PCM "A" | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2.5 [s] continuous | 0 DCY | |
| valid message from ECM | received | |||||||||
| Hybrid CAN: Engine Control Module (ECM) | U0401 | invalid data received from ECM/PCM "A" | received message | implausible message | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| valid message from ECM | received | |||||||||
| Hybrid CAN: Body Control Module "A" | U0140 | lost communication with Body Control Module | message time out | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 2 DCY | |
| Comfort CAN | active | |||||||||
| Hybrid CAN: Body Control Module "A" | U0141 | lost communication with Body Control Module "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| ComfortCAN | active | |||||||||
| Hybrid CAN: Gateway "A" | U0146 | lost communication with Gateway "A" | message time out | detected | (BECM mode | = AC_CHARGING | [ms] | 1 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| time after ECU wake up | > 500 | |||||||||
| any Hybrid CAN message | received | |||||||||
| Hybrid CAN: Gateway "A" | U0447 | invalid data received from Gateway "A" | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from Gateway | received | |||||||||
| Hybrid CAN: Gateway "A" | U0447 | invalid data received from Gateway "A" | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from Gateway | received | |||||||||
| Hybrid CAN: Gateway "A" | U0447 | invalid data received from Gateway "A" | BECM target mode | != AC_CHARGING | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| != HV_OFF | valid message from Gateway | received | ||||||||
| != HV_ON | ||||||||||
| Hybrid CAN: Battery Charger Control Module (BCCM) | U019B | lost communication with Battery Charger Control Module "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| Hybrid CAN communication | active | |||||||||
| Hybrid CAN: Battery Charger Control Module (BCCM) | U019B | lost communication with Battery Charger Control Module "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| Hybrid CAN communication | active | |||||||||
| Hybrid CAN: Battery Charger Control Module (BCCM) | U019B | lost communication with Battery Charger Control Module "A" | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| Hybrid CAN communication | active | |||||||||
| Hybrid CAN: Coolant Temperature Control Module | U0116 | lost communication with Coolant Temperature Control Module | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 2 DCY | |
| Hybrid CAN communication | active | |||||||||
| Hybrid CAN: Coolant Temperature Control Module | U0116 | lost communication with Coolant Temperature Control Module | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| Hybrid CAN communication | active | |||||||||
| Hybrid CAN: Coolant Temperature Control Module | U0456 | invalid data received from Coolant Temperature Control Module | received message | implausible message | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| valid message from VTMC | received | |||||||||
| Hybrid CAN: Coolant Temperature Control Module | U0456 | invalid data received from Coolant Temperature Control Module | received message | implausible message | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| valid message from VTMC | received | |||||||||
| Battery CAN | U0037 | vehicle communication bus B | CAN controller enters "BUS OFF" state | 3 times in a row | time after ECU wake up | > 500 | [ms] | 10 [ms] continuous | 0 DCY | |
| Battery CAN | U0038 | vehicle communication bus B performance (global time out) | CAN messages | not received | time after ECU wake up | > 500 | [ms] | 450 [ms] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 500 [ms] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 500 [ms] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 20 [ms] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 4 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 4 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 4 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 4 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 4 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U029A | lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| any Battery CAN message | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 800 [ms] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 800 [ms] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 800 [ms] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from BJB | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U04A1 | invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-01 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "A" | U01A0 | lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U04A2 | invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-02 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "B" | U01A1 | lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U04A3 | invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-03 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "C" | U01A2 | lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U02A0 | invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-04 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "D" | U01A3 | lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U04A5 | invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-05 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "E" | U01A4 | lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U04A6 | invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-06 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "F" | U01A5 | lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U04A7 | invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-07 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "G" | U01A6 | lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 2 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 200 [ms] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message counter error | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | checksum error | detected | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | received message | implausible | time after ECU wake up | > 500 | [ms] | 1 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U04A8 | invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) | received message | implausible | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 0 DCY | |
| valid message from CMC-08 | received | |||||||||
| Battery CAN: Hybrid/EV Battery Interface Control Module "H" | U01A7 | lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) | message time out | detected | time after ECU wake up | > 500 | [ms] | 5 [s] continuous | 2 DCY | |
| CMC power supply | active | |||||||||
| Battery CAN: Hybrid/EV Battery Pack Sensor Module | U059B | invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) | BJB error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "A" (CMC-01) | P0DAF | range/performance (invalid data) (CMC-01) | CMC-01 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "B" (CMC-02) | P0DB3 | range/performance (invalid data) (CMC-02) | CMC-02 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "C" (CMC-03) | P0DB7 | range/performance (invalid data) (CMC-03) | CMC-03 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "D" (CMC-04) | P0DBB | range/performance (invalid data) (CMC-04) | CMC-04 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "E" (CMC-05) | P0DBF | range/performance (invalid data) (CMC-05) | CMC-05 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "F" (CMC-06) | P0DC3 | range/performance (invalid data) (CMC-06) | CMC-06 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "G" (CMC-07) | P0DC7 | range/performance (invalid data) (CMC-07) | CMC-07 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "H" (CMC-08) | P0DCB | range/performance (invalid data) (CMC-08) | CMC-08 error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 0 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Hardware/Internal Malfunctions | ||||||||||
| BJB: Internal Hardware Check (Self Test) | P0AFC | internal hardware check (self test) | CASE 1: | CASE 1: | CASE 1: | 0 DCY | ||||
| crash self test | not completed | BJB mode | = INIT | 4.5 [s] | ||||||
| OR | Battery CAN communication | active | ||||||||
| non-volatile memory reading | not completed | BJB error memory status flag | valid | CASE 2: | ||||||
| OR | 550 [ms] | |||||||||
| sensor data | not available | CASE 2 to 9: | ||||||||
| OR | Battery CAN communication | active | CASE 3: | |||||||
| hardware revision | not available | BJB error memory status flag | valid | 1 [s] | ||||||
| CASE 2: | CASE 4: | |||||||||
| contactor control command and contactor control feedback signal | not equal | 5500 [ms] | ||||||||
| CASE 3: | CASE 5: | |||||||||
| Mosfet control command and mosfet control feedback signal | not equal | 1 [s] | ||||||||
| CASE 4: | CASE 6: | |||||||||
| Difference between temperature @ control board NTC and temperature @ shunt NTC 1 | > |20| | [°C] | 1 [s] | |||||||
| OR | ||||||||||
| Difference between temperature @ shunt NTC 1 and temperature @ shunt NTC 2 | > |20| | [°C] | CASE 7: | |||||||
| CASE 5: | 550 [ms] | |||||||||
| deviation between positive battery voltage and voltage @ main fuse | > |20| | [V] | CASE 8: | |||||||
| CASE 6: | 750 [ms] | |||||||||
| deviation between positive system voltage and voltage @ battery charger fuse | > |20| | [V] | CASE 9: | |||||||
| CASE 7: | 550 [ms] | |||||||||
| ADC internal reference voltage of main processor | ≥1.32 | [V] | ||||||||
| OR | ||||||||||
| ADC internal reference voltage of main processor | ≤ 1.08 | [V] | ||||||||
| CASE 8: | ||||||||||
| HV isolated positive supply voltage | > 7 | [V] | ||||||||
| OR | < 5.5 | [V] | ||||||||
| HV isolated negative supply voltage | > -2 | [V] | ||||||||
| CASE 9: | < -6 | [V] | ||||||||
| 3.3V supply voltage | > 3.6 | [V] | ||||||||
| OR | < 3 | [V] | ||||||||
| 5V supply voltage | > 5.4 | [V] | ||||||||
| < 4.6 | [V] | |||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BJB: Internal Memory | P0AFC | RAM check | CASE 1: | CASE 1: | CASE 1: | 0 DCY | ||||
| error correcting code failure | detected | BECM mode | = INIT | 850 [ms] once / DCY | ||||||
| CASE 2: | CASE 1 & 2: | CASE 2: | ||||||||
| ECC correction check logic | failed | Battery CAN communication | active | 500 [ms] continuous | ||||||
| BJB error memory status flag | valid | |||||||||
| BJB: EEPROM | P0AFC | EEPROM check | memory checksum error | detected | BECM mode | = INIT | 850 [ms] once / DCY | 0 DCY | ||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Analog-to-Digital-Converter 1 | P0AFC | analog-to -digital converter 1 internal hardware check | internal reference voltage | > 5.5 | [V] | Battery CAN communication | active | 750 [ms] continuous | 0 DCY | |
| < 4.5 | [V] | BJB error memory status flag | valid | |||||||
| BJB: Analog-to-Digital-Converter 2 | P0AFC | analog-to -digital converter 2 internal hardware check | CASE 1: | CASE 1 & 2: | CASE 1 & 3 & 4: | 0 DCY | ||||
| internal reference voltage for current measurement | >130 | [mV] | BECM mode | = INIT | 700 [ms] continuous | |||||
| <110 | [mV] | Battery CAN communication | active | |||||||
| OR | BJB error memory status flag | valid | CASE 2: | |||||||
| internal reference voltage for voltage measurement | > 1.2 | [V] | 5.5 [s] continuous | |||||||
| < 0.8 | [V] | CASE 3 & 4: | ||||||||
| OR | Battery CAN communication | active | ||||||||
| internal resistance ratio for temperature measurement | > 0.763 | [%] | BJB error memory status flag | valid | ||||||
| CASE 2: | < 0.534 | [%] | ||||||||
| main processor data | not received | |||||||||
| CASE 3: | ||||||||||
| ADC values | not received | |||||||||
| CASE 4: | ||||||||||
| shunt resistance | > 1.25 | [MOhm] | ||||||||
| BJB: Hardware Disable Malfunction | P0AFC | plausibility check | CASE 1: | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| Hardware-Disable output voltage | > 3.703 | [V] | BJB error memory status flag | valid | 1.5 [s] continuous | |||||
| Hardware-Disable comparator output | 0 | |||||||||
| OR | CASE 2 to 6: | |||||||||
| Hardware-Disable output voltage | < 2.381 | [V] | 2.5 [s] continuous | |||||||
| Hardware-Disable comparator output | 1 | |||||||||
| CASE 2: | ||||||||||
| car crash | detected | |||||||||
| contactor power supply activity signal | active | |||||||||
| CASE 3: | ||||||||||
| emergency off command | issued | |||||||||
| contactor power supply activity signal | active | |||||||||
| CASE 4: | ||||||||||
| contactor power supply output voltage | < 4 | [V] | ||||||||
| contactor power supply activity signal | active | |||||||||
| CASE 5: | ||||||||||
| contactor power supply output voltage | > 6 | [V] | ||||||||
| contactor power supply activity signal | inactive | |||||||||
| CASE 6: | ||||||||||
| Hardware-Disable output voltage | > 3.703 | [V] | ||||||||
| Hardware-Disable comparator output | 1 | |||||||||
| contactor power supply input voltage | < 16.2 | [V] | ||||||||
| contactor power supply input voltage | > 7.8 | [V] | ||||||||
| car crash | not detected | |||||||||
| contactor power supply activity signal | inactive | |||||||||
| contactor power supply output voltage | <4 | [V] | ||||||||
| BJB: Hardware Disable Line | P0E2D | performance (circuit high/out of range high) | CASE 1: short to battery | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured voltage | > 17 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured voltage | > 16 | [V] | ||||||||
| ≤ 17 | [V] |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BJB: Hardware Disable Line | P0E2D | performance (open circuit) | actual value of Hardware-Disable state | = disable | target value of Hardware-Disable state | = enable | 600 [ms] continuous | 0 DCY | ||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Current Sensors | ||||||||||
| BJB: Hybrid/EV Battery Pack Current Sensor "A" | P0AC2 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured shunt current | > 455 | [A] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured shunt current | > 400 | [A] | ||||||||
| ≤ 455 | [A] | |||||||||
| BJB: Hybrid/EV Battery Pack Current Sensor "A" | P0AC1 | circuit low/out of range low | CASE 1: circuit low | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured shunt current | < -455 | [A] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range low | ||||||||||
| measured current | < -400 | [A] | ||||||||
| ≥ -455 | [A] | |||||||||
| BJB: Hybrid/EV Battery Pack Current Sensor "A" | P0AC0 | circuit range/performance (internal hardware check) | internal communication time out | detected | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | ||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Pack Current Sensor "B" | P0B11 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |||
| measured hull current | > 455 | [A] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured hull current | > 400 | [A] | ||||||||
| ≤ 455 | [A] | |||||||||
| BJB: Hybrid/EV Battery Pack Current Sensor "B" | P0B10 | circuit low/out of range low | CASE 1: circuit low | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |||
| measured hull current | < -455 | [A] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range low | ||||||||||
| measured hull current | < -400 | [A] | ||||||||
| ≥ -455 | [A] | |||||||||
| BJB: Hybrid/EV Battery Pack Current Sensor "B" | P0B0F | circuit range/performance (internal hardware check) | deviation between sensor "B" digital value and sensor "B" analog value | ≥ |50| | [A] | Battery CAN communication | active | 750 [ms] continuous | 2 DCY | |
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Pack Current Sensors "A" and "B" | P0B13 | rationality check | CASE 1: | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| deviation between measured current value of sensor 1 and measured current value of sensor 2 | > |3|+ |5% of the current value of sensor 1 | | [A] | BJB error memory status flag | valid | 1.5 [s] continuous | |||||
| CASE 2: | CASE 2: | |||||||||
| deviation between measured current value of sensor 1 and measured current value of sensor 2 | > |50| | [A] | 750 [ms] continuous | |||||||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Temperature Sensors | ||||||||||
| BJB: Temperature Sensors | P0AFC | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1.5 [s] continuous | 2 DCY | |||
| signal value of control board NTC temperature voltage | ≤ -45 | [°C] | BJB error memory status flag | valid | ||||||
| OR | ||||||||||
| corresponding temperature of shunt board NTC sensor signal value | ≤ -45 | [°C] | ||||||||
| OR | ||||||||||
| signal value of shunt NTC 1 temperature voltage | ≤ -45 | [°C] | ||||||||
| OR | ||||||||||
| signal value of shunt NTC 2 temperature voltage | ≤ -45 | [°C] | ||||||||
| CASE 2: out of range high | ||||||||||
| signal value of control board NTC temperature voltage | < - 40 | [°C] | ||||||||
| OR | > -45 | [°C] | ||||||||
| corresponding temperature of shunt board NTC sensor signal value | < - 40 | [°C] | ||||||||
| OR | > -45 | [°C] | ||||||||
| signal value of shunt NTC 1 temperature voltage | < - 40 | [°C] | ||||||||
| OR | > -45 | [°C] | ||||||||
| signal value of shunt NTC 2 temperature voltage | < - 40 | [°C] | ||||||||
| > -45 | [°C] | |||||||||
| BJB: Temperature Sensors | P0AFC | circuit low/out of range low | CASE 1: circuit low | Battery CAN communication | active | 1.5 [s] continuous | 2 DCY | |||
| signal value of control board NTC temperature voltage | ≥ 135 | [°C] | BJB error memory status flag | valid | ||||||
| OR | ||||||||||
| corresponding temperature of shunt board NTC sensor signal value | ≥ 135 | [°C] | ||||||||
| OR | ||||||||||
| signal value of shunt NTC 1 temperature voltage | ≥ 135 | [°C] | ||||||||
| OR | ||||||||||
| signal value of shunt NTC 2 temperature voltage | ≥ 135 | [°C] | ||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| CASE 2: out of range low | ||||||||||
| signal value of control board NTC temperature voltage | > 125 | [°C] | ||||||||
| OR | < 135 | [°C] | ||||||||
| corresponding temperature of shunt board NTC sensor signal value | > 125 | [°C] | ||||||||
| OR | < 135 | [°C] | ||||||||
| signal value of shunt NTC 1 temperature voltage | > 125 | [°C] | ||||||||
| OR | < 135 | [°C] | ||||||||
| signal value of shunt NTC 2 temperature voltage | > 125 | [°C] | ||||||||
| < 135 | [°C] | |||||||||
| BJB: Temperature Sensors | P0AFC | rationality check high | difference between any BJB temperature and median value of all BJB temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 1 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| BJB: Temperature Sensors | P0AFC | rationality check low | difference between any BJB temperature and median value of all BJB temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 1 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Voltage Sensors | ||||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor | P0ABD | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured voltage | > 505 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured voltage | > 465 | [V] | ||||||||
| ≤ 505 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor | P0ABC | circuit low/out of range low | CASE 1: circuit low | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured voltage | < 2 | [V] | BJB error memory status flag | valid | ||||||
| deviation between battery voltage and voltage @ main fuse | > |20| | [V] | ||||||||
| CASE 2: out of range low | ||||||||||
| measured voltage | < 160 | [V] | ||||||||
| ≥ 2 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor | P0ABB | circuit range/performance (rationality check high) | difference between battery voltage and sum of all cell voltages | > 40 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
| BECM mode | = PRECHARGE | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor | P0ABB | circuit range/performance (rationality check low) | difference between battery voltage and sum of all cell voltages | < -40 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| OR | ||||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = PRECHARGE | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Positive Terminal Sensor | P0B17 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured system voltage at positive terminal | > 505 | [V] | BJB error memory status flag | valid | 1 [s] continuous | 0 DCY | ||||
| CASE 2: out of range high | ||||||||||
| measured system voltage at positive terminal | > 465 | [V] | ||||||||
| ≤ 505 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Positive Terminal Sensor | P0B16 | circuit low | measured system voltage at positive terminal | < -30 | [V] | (BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Positive Terminal Sensor | P0B14 | circuit open | deviation between measured system voltage @ positive terminal and measured voltage @ battery charger fuse | > |20| | [V] | (BECM mode | = AC_CHARGING | 1 [s] continuous | 0 DCY | |
| measured system voltage at positive terminal | < 10 | [V] | OR | |||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Negative Terminal Sensor | P0B17 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured system voltage at negative terminal | > 505 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured system voltage at negative terminal | > 465 | [V] | ||||||||
| ≤ 505 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" - System Voltage Negative Terminal Sensor | P0B16 | circuit low/out of range low | CASE 1: circuit low | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured system voltage at negative terminal | < -505 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range low | ||||||||||
| measured system voltage at negative terminal | < -465 | [V] | ||||||||
| ≥ -505 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" | P0B15 | circuit range/performance (rationality check high) | difference between system voltage and battery voltage | > 40 | [V] | BECM mode | = AC_CHARGING | 2 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "B" | P0B15 | circuit range/performance (rationality check low) | difference between system voltage and battery voltage | < -40 | [V] | BECM mode | = AC_CHARGING | 2 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "C" | P0B1C | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured voltage at hybrid/EV battery pack voltage sensor "C" | > 505 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured voltage at hybrid/EV battery pack voltage sensor "C" | > 465 | [V] | ||||||||
| ≤ 505 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "C" | P0B1B | circuit low/out of range low | CASE 1: circuit low | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured voltage at hybrid/EV battery pack voltage sensor "C" | < -30 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range low | ||||||||||
| measured voltage at hybrid/EV battery pack voltage sensor "C" | < 140 | [V] | ||||||||
| ≥ -30 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "D" | P0B21 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |||
| measured voltage at hybrid/EV battery pack voltage sesnor "D" | > 505 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured voltage at hybrid/EV battery pack voltage sesnor "D" | > 465 | [V] | ||||||||
| ≤ 505 | [V] | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "D" | P0B20 | circuit low | measured voltage at hybrid/EV battery pack voltage sesnor "D" | < -30 | [V] | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Pack Voltage Sensor "D" | P0B1E | open circuit | deviation between measured system voltage at positive terminal and measured voltage at hybrid/EV battery pack voltage sesnor "D" | > 20 | [V] | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |
| measured voltage at hybrid/EV battery pack voltage sesnor "D" | < 10 | [V] | BJB error memory status flag | valid | ||||||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Low Voltage Sensors | ||||||||||
| BJB: Sensor Power Supply "B" | P06B5 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |||
| measured voltage | > 26 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured voltage | > 16.2 | [V] | ||||||||
| ≤ 26 | [V] | |||||||||
| BJB: Sensor Power Supply "B" | P06B4 | circuit low | measured voltage | < 7.8 | [V] | Battery CAN communication | active | 1 [s] continuous | 2 DCY | |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BJB error memory status flag | valid | |||||||||
| BJB: contactor Supply Voltage Sensor | P0B36 | circuit high/out of range high | CASE 1: circuit high | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |||
| measured voltage | > 26 | [V] | BJB error memory status flag | valid | ||||||
| CASE 2: out of range high | ||||||||||
| measured voltage | > 16.2 | [V] | ||||||||
| ≤ 26 | ||||||||||
| BJB: contactor Supply Voltage Sensor | P0B35 | circuit low | measured voltage | < 7.8 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| BJB error memory status flag | valid | |||||||||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - contactors | ||||||||||
| BJB: Hybrid/EV Battery Positive Main contactor Circuit | P0AA1 | stuck closed | deviation between voltages before and after the main contactor on the positive HV busbar | < |20| | [V] | (BECM mode | = HV_OFF | 4.5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode) | = EMERGENCY_OFF | |||||||||
| positive main contactor is commanded | open | |||||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Positive Main contactor Circuit | P0AA2 | stuck open | deviation between voltage before and after the main contactor on the positive HV busbar | > |60| | [V] | (BECM mode | = AC_CHARGING | 1.5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Negative Main contactor Circuit | P0AA4 | stuck closed | measured voltage after the main contactor on the negative HV busbar | < 20 | [V] | (BECM mode | = HV_OFF | 4.5 [s] continuous | 0 DCY | |
| modeled voltage after the main contactor on the negative HV busbar | > 20 | [V] | OR | |||||||
| BECM mode) | = EMERGENCY_OFF | |||||||||
| negative main contactor is commanded | open | |||||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Negative Main contactor Circuit | P0AA5 | stuck open | voltage on the negative HV busbar | > 60 | [V] | (BECM mode | = AC_CHARGING | 1.5 [s] continuous | 0 DCY | |
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Precharge contactor Circuit | P0AE3 | stuck open | precharge energy | = 0 | [Ws] | BECM mode | = PRECHARGE | 1 [s] | 0 DCY | |
| negative main contactor remains open error (P0AA5) | not detected | precharge time out (P0C78) | detected | continuous | ||||||
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Hybrid/EV Battery Positive Main contactor Control | P0AD9 | circuit open (functional check) | contactor supply voltage | > 10 | [V] | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | |
| contactor driver feedback current | > 650 | [mA] | BJB error memory status flag | valid | ||||||
| BJB: Hybrid/EV Battery Positive Main contactor Control | P0ADC | circuit high | contactor driver input | OFF | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | ||
| contactor driver feedback current | > 100 | [mA] | BJB error memory status flag | valid | ||||||
| < 650 | [mA] | |||||||||
| BJB: Hybrid/EV Battery Positive Main contactor Control | P0ADB | circuit low | contactor driver input | ON | [mA] | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | |
| contactor driver feedback current | < 100 | BJB error memory status flag | valid | |||||||
| BJB: Hybrid/EV Battery Negative Main contactor Control | P0ADD | circuit open (functional check) | contactor supply voltage | > 10 | [V] | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | |
| contactor driver feedback current | > 650 | [mA] | BJB error memory status flag | valid | ||||||
| BJB: Hybrid/EV Battery Negative Main contactor Control | P0AE0 | circuit high | contactor driver input | OFF | [mA] | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | |
| contactor driver feedback current | > 100 | BJB error memory status flag | valid | |||||||
| BJB: Hybrid/EV Battery Negative Main contactor Control | P0ADF | circuit low | contactor driver input | ON | [mA] | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | |
| contactor driver feedback current | < 100 | BJB error memory status flag | valid | |||||||
| BJB: Hybrid/EV Battery Precharge contactor Control | P0AE7 | circuit high | contactor driver input | OFF | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | ||
| contactor driver feedback | ON | BJB error memory status flag | valid | |||||||
| BJB: Hybrid/EV Battery Precharge contactor Control | P0AE6 | circuit low | contactor driver input | ON | Battery CAN communication | active | 700 [ms] continuous | 0 DCY | ||
| contactor driver feedback | OFF | BJB error memory status flag | valid | |||||||
| Hybrid/EV Battery Pack Sensor Module (Battery Junction Box (BJB)) - Protective Functions | ||||||||||
| BJB: Precharging System | P0CA7 | discharging current high | measured shunt current | < - 8 | [A] | BECM mode | = PRECHARGE | 550 [ms] continuous | 0 DCY | |
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| BJB: Precharging System | P0C78 | functional check: precharge time too long | deviation between battery positive voltage and system voltage | > |10| | [V] | BECM mode | = PRECHARGE | 1 [s] continuous | 0 DCY | |
| Battery CAN communication | active | |||||||||
| BJB error memory status flag | valid | |||||||||
| Battery Junction Box (BJB) - Communication Monitoring | ||||||||||
| BJB: Communication | U0111 | lost communication with Battery Energy Contrl Module "A" | CASE 1: | CASE 1: | CASE 1: | 0 DCY | ||||
| message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | ||||||
| CASE 2: | BJB error memory status flag | valid | CASE 2: | |||||||
| message counter error | detected | CASE 2 & 3: | 1.5 [s] continuous | |||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| detected | Battery CAN communication | active | ||||||||
| CASE 3: | BJB error memory status flag | valid | ||||||||
| checksum error | message from BECM | received | CASE 3: | |||||||
| 600 [ms] continuous | ||||||||||
| Cell Module Controller (CMC) - Hardware/Internal Malfunctions | ||||||||||
| CMC-01: Internal Memory | P0DAC | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-01 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-01: AD Converter | P0DAC | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-01 error memory status flag | valid | |||||||||
| CMC-01: Internal Error | P0DAC | internal error in main path | CASE 1: | [%] | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | detected | CMC-01 error memory status flag | valid | 550 [ms] continuous | ||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: | ||||||||
| Cell voltage deviation between FET switch on and FET switch off | < 2 | Start up | initiated | 1.5 [s] once / DCY | ||||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-02: Internal Memory | P0DB0 | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-02 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-02: AD Converter | P0DB0 | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-02 error memory status flag | valid | |||||||||
| CMC-02: Internal Error | P0DB0 | internal error in main path | CASE 1: | [%] | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | detected | CMC-02 error memory status flag | valid | 550 [ms] continuous | ||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: | ||||||||
| Cell voltage deviation between FET switch on and FET switch off | < 2 | Start up | initiated | 1.5 [s] once / DCY | ||||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-03: Internal Memory | P0DB4 | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-03 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-03: AD Converter | P0DB4 | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-03 error memory status flag | valid | |||||||||
| CMC-03: Internal Error | P0DB4 | internal error in main path | CASE 1: | detected | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | CMC-03 error memory status flag | valid | 550 [ms] continuous | |||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: | ||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Cell voltage deviation between FET switch on and FET switch off | < 2 | [%] | Start up | initiated | 1.5 [s] once / DCY | |||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-04: Internal Memory | P0DB8 | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-04 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-04: AD Converter | P0DB8 | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-04 error memory status flag | valid | |||||||||
| CMC-04: Internal Error | P0DB8 | internal error in main path | CASE 1: | [%] | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | detected | CMC-04 error memory status flag | valid | 550 [ms] continuous | ||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: | ||||||||
| Cell voltage deviation between FET switch on and FET switch off | < 2 | Start up | initiated | 1.5 [s] once / DCY | ||||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-05: Internal Memory | P0DBC | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-05 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-05: AD Converter | P0DBC | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-05 error memory status flag | valid | |||||||||
| CMC-05: Internal Error | P0DBC | internal error in main path | CASE 1: | [%] | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | detected | CMC-05 error memory status flag | valid | 550 [ms] continuous | ||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: | ||||||||
| Cell voltage deviation between FET switch on and FET switch off | < 2 | Start up | initiated | 1.5 [s] once / DCY | ||||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-06: Internal Memory | P0DC0 | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-06 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-06: AD Converter | P0DC0 | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-06 error memory status flag | valid | |||||||||
| CMC-06: Internal Error | P0DC0 | internal error in main path | CASE 1: | detected | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | CMC-06 error memory status flag | valid | 550 [ms] continuous | |||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Cell voltage deviation between FET switch on and FET switch off | < 2 | [%] | Start up | initiated | 1.5 [s] once / DCY | |||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-07: Internal Memory | P0DC4 | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-07 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-07: AD Converter | P0DC4 | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-07 error memory status flag | valid | |||||||||
| CMC-07: Internal Error | P0DC4 | internal error in main path | CASE 1: | [%] | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | detected | CMC-07 error memory status flag | valid | 550 [ms] continuous | ||||||
| CASE 2: | Additionally for CASE 2: | CASE 2: | ||||||||
| Cell voltage deviation between FET switch on and FET switch off | < 2 | Start up | initiated | 1.5 [s] once / DCY | ||||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| CMC-08: Internal Memory | P0DC8 | internal memory tests | CASE 1: RAM/ROM error during operation | Battery CAN communication | active | CASE 1: | 0 DCY | |||
| RAM/ROM error | detected | CMC-08 error memory status flag | valid | 500 [ms] continuous | ||||||
| CASE 2: RAM/ROM error during startup | CASE 2 & 3: | |||||||||
| RAM/ROM error | detected | 500 [ms] once / DCY | ||||||||
| CASE 3: ECC logic test error | ||||||||||
| During ECC logic test, error code | detected | |||||||||
| CMC-08: AD Converter | P0DC8 | AD converter error of main path | number of communication errors between microcontroller and AD converter | ≥ 20 | [-] | Battery CAN communication | active | 2.5 [s] continuous | 0 DCY | |
| CMC-08 error memory status flag | valid | |||||||||
| CMC-08: Internal Error | P0DC8 | internal error in main path | CASE 1: | [%] | Battery CAN communication | active | CASE 1: | 0 DCY | ||
| Daisy chain stuck error | detected | CMC-08 error memory status flag | valid | 550 [ms] continuous | ||||||
| CASE 2: Balancing FET monitoring | Additionally for CASE 2: | CASE 2: | ||||||||
| Cell voltage deviation between FET switch on and FET switch off | < 2 | Start up | initiated | 1.5 [s] once / DCY | ||||||
| CASE 3: | Additionally for CASE 3: | CASE 3: | ||||||||
| Watchdog test error | detected | Shut down | initiated | 500 [ms] once / DCY | ||||||
| CASE 4: | CASE 4: | |||||||||
| MCU malfunction | detected | 500 [ms] continuous | ||||||||
| Cell Module Controller (CMC) - Temperature Sensors | ||||||||||
| Hybrid/EV Battery Temperature Sensor "A" (CMC-01) | P0A9D | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-01 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "A" (CMC-01) | P0A9E | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-01 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "A" (CMC-01) | P0A9C | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-01 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "A" (CMC-01) | P0A9C | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-01 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "B" (CMC-02) | P0AC7 | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-02 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "B" (CMC-02) | P0AC8 | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-02 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "B" (CMC-02) | P0AC6 | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-02 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "B" (CMC-02) | P0AC6 | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-02 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "C" (CMC-03) | P0ACC | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-03 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "C" (CMC-03) | P0ACD | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-03 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "C" (CMC-03) | P0ACB | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-03 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "C" (CMC-03) | P0ACB | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-03 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "D" (CMC-04) | P0AEA | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-04 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "D" (CMC-04) | P0AEB | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-04 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "D" (CMC-04) | P0AE9 | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-04 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "D" (CMC-04) | P0AE9 | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-04 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "E" (CMC-05) | P0BC4 | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-05 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "E" (CMC-05) | P0BC5 | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-05 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "E" (CMC-05) | P0BC3 | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-05 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "E" (CMC-05) | P0BC3 | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-05 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "F" (CMC-06) | P0C35 | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-06 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "F" (CMC-06) | P0C36 | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-06 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Hybrid/EV Battery Temperature Sensor "F" (CMC-06) | P0C34 | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-06 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "F" (CMC-06) | P0C34 | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-06 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "G" (CMC-07) | P0C7E | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-07 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "G" (CMC-07) | P0C7F | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-07 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "G" (CMC-07) | P0C7D | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-07 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "G" (CMC-07) | P0C7D | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-07 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "H" (CMC-08) | P0C83 | circuit low (temperature out of range high) | measured cell temperature (from internal cell temperature sensor 1) | > 85 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-08 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | > 85 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "H" (CMC-08) | P0C84 | circuit high (temperature out of range low) | measured cell temperature (from internal cell temperature sensor 1) | < -40 | [°C] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| OR | No internal communication error in CMC-08 | |||||||||
| measured cell temperature (from internal cell temperature sensor 2) | < -40 | [°C] | ||||||||
| Hybrid/EV Battery Temperature Sensor "H" (CMC-08) | P0C82 | circuit range/performance (temperature rationality check high) | difference between cell internal temperature of CMC-08 and median value of all cell temperatures | ≥ 8...15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode) | = RUN_ON | |||||||||
| Hybrid/EV Battery Temperature Sensor "H" (CMC-08) | P0C82 | circuit range/performance (temperature rationality check low) | difference between cell internal temperature of CMC-08 and median value of all cell temperatures | ≤ -8...-15 | [°C] | HV off time calculations status | time calculated | [min] | 2.7 [s] continuous | 2 DCY |
| HV off time | ≥ 360...720 | |||||||||
| (BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = INIT | |||||||||
| OR | ||||||||||
| BECM mode | = LOCAL_ACTIVE | |||||||||
| OR | ||||||||||
| BECM mode) | = RUN_ON | |||||||||
| Cell Module Controller (CMC) - Cell Voltage Sensors | ||||||||||
| Hybrid/EV Battery Voltage Sensor "A" (CMC-01) | P0B3E | circuit high | measured cell voltages in CMC-01 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-01 error memory status flag | valid | |||||||||
| No internal communication error in CMC-01 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "A" (CMC-01) | P0B3D | circuit low | measured cell voltages in CMC-01 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-01 error memory status flag | valid | |||||||||
| No internal communication error in CMC-01 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "A" (CMC-01) | P0B3B | open circuit | measured cell voltages of broken line and the next higher line in CMC-01 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-01 error memory status flag | valid | |||||||||
| No internal communication error in CMC-01 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "A" (CMC-01) | P0B3C | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-01 and ASIC voltage of CMC-01 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-01 and mean value (ASIC voltage of CMC-01 divided by number of cells in CMC-01) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "A" (CMC-01) | P0B3C | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-01 and ASIC voltage of CMC-01 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-01 and mean value (ASIC voltage of CMC-01 divided by number of cells in CMC-01) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "B" (CMC-02) | P0B43 | circuit high | measured cell voltages in CMC-02 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-02 error memory status flag | valid | |||||||||
| No internal communication error in CMC-02 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "B" (CMC-02) | P0B42 | circuit low | measured cell voltages in CMC-02 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-02 error memory status flag | valid | |||||||||
| No internal communication error in CMC-02 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "B" (CMC-02) | P0B40 | open circuit | measured cell voltages of broken line and the next higher line in CMC-02 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-02 error memory status flag | valid | |||||||||
| No internal communication error in CMC-02 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "B" (CMC-02) | P0B41 | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-02 and ASIC voltage of CMC-02 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-02 and mean value (ASIC voltage of CMC-02 divided by number of cells in CMC-02) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "B" (CMC-02) | P0B41 | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-02 and ASIC voltage of CMC-02 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-02 and mean value (ASIC voltage of CMC-02 divided by number of cells in CMC-02) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "C" (CMC-03) | P0B48 | circuit high | measured cell voltages in CMC-03 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-03 error memory status flag | valid | |||||||||
| No internal communication error in CMC-03 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "C" (CMC-03) | P0B47 | circuit low | measured cell voltages in CMC-03 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-03 error memory status flag | valid | |||||||||
| No internal communication error in CMC-03 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "C" (CMC-03) | P0B45 | open circuit | measured cell voltages of broken line and the next higher line in CMC-03 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| CMC-03 error memory status flag | valid | |||||||||
| No internal communication error in CMC-03 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "C" (CMC-03) | P0B46 | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-03 and ASIC voltage of CMC-03 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-03 and mean value (ASIC voltage of CMC-03 divided by number of cells in CMC-03) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "C" (CMC-03) | P0B46 | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-03 and ASIC voltage of CMC-03 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-03 and mean value (ASIC voltage of CMC-03 divided by number of cells in CMC-03) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "D" (CMC-04) | P0B4D | circuit high | measured cell voltages in CMC-04 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-04 error memory status flag | valid | |||||||||
| No internal communication error in CMC-04 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "D" (CMC-04) | P0B4C | circuit low | measured cell voltages in CMC-04 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-04 error memory status flag | valid | |||||||||
| No internal communication error in CMC-04 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "D" (CMC-04) | P0B4A | open circuit | measured cell voltages of broken line and the next higher line in CMC-04 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-04 error memory status flag | valid | |||||||||
| No internal communication error in CMC-04 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "D" (CMC-04) | P0B4B | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-04 and ASIC voltage of CMC-04 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-04 and mean value (ASIC voltage of CMC-04 divided by number of cells in CMC-04) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "D" (CMC-04) | P0B4B | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-04 and ASIC voltage of CMC-04 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-04 and mean value (ASIC voltage of CMC-04 divided by number of cells in CMC-04) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "E" (CMC-05) | P0B52 | circuit high | measured cell voltages in CMC-05 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-05 error memory status flag | valid | |||||||||
| No internal communication error in CMC-05 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "E" (CMC-05) | P0B51 | circuit low | measured cell voltages in CMC-05 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-05 error memory status flag | valid | |||||||||
| No internal communication error in CMC-05 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "E" (CMC-05) | P0B4F | open circuit | measured cell voltages of broken line and the next higher line in CMC-05 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-05 error memory status flag | valid | |||||||||
| No internal communication error in CMC-05 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "E" (CMC-05) | P0B50 | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-05 and ASIC voltage of CMC-05 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-05 and mean value (ASIC voltage of CMC-05 divided by number of cells in CMC-05) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "E" (CMC-05) | P0B50 | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-05 and ASIC voltage of CMC-05 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-05 and mean value (ASIC voltage of CMC-05 divided by number of cells in CMC-05) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "F" (CMC-06) | P0B57 | circuit high | measured cell voltages in CMC-06 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-06 error memory status flag | valid | |||||||||
| No internal communication error in CMC-06 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "F" (CMC-06) | P0B56 | circuit low | measured cell voltages in CMC-06 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| CMC-06 error memory status flag | valid | |||||||||
| No internal communication error in CMC-06 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "F" (CMC-06) | P0B54 | open circuit | measured cell voltages of broken line and the next higher line in CMC-06 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-06 error memory status flag | valid | |||||||||
| No internal communication error in CMC-06 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "F" (CMC-06) | P0B55 | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-06 and ASIC voltage of CMC-06 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-06 and mean value (ASIC voltage of CMC-06 divided by number of cells in CMC-06) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "F" (CMC-06) | P0B55 | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-06 and ASIC voltage of CMC-06 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-06 and mean value (ASIC voltage of CMC-06 divided by number of cells in CMC-06) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "G" (CMC-07) | P0B5C | circuit high | measured cell voltages in CMC-07 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-07 error memory status flag | valid | |||||||||
| No internal communication error in CMC-07 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "G" (CMC-07) | P0B5B | circuit low | measured cell voltages in CMC-07 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-07 error memory status flag | valid | |||||||||
| No internal communication error in CMC-07 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "G" (CMC-07) | P0B59 | open circuit | measured cell voltages of broken line and the next higher line in CMC-07 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-07 error memory status flag | valid | |||||||||
| No internal communication error in CMC-07 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "G" (CMC-07) | P0B5A | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-07 and ASIC voltage of CMC-07 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-07 and mean value (ASIC voltage of CMC-07 divided by number of cells in CMC-07) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "G" (CMC-07) | P0B5A | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-07 and ASIC voltage of CMC-07 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-07 and mean value (ASIC voltage of CMC-07 divided by number of cells in CMC-07) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "H" (CMC-08) | P0B61 | circuit high | measured cell voltages in CMC-08 | > 4.5 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-08 error memory status flag | valid | |||||||||
| No internal communication error in CMC-08 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "H" (CMC-08) | P0B60 | circuit low | measured cell voltages in CMC-08 | < 1 | [V] | Battery CAN communication | active | 1 [s] continuous | 0 DCY | |
| CMC-08 error memory status flag | valid | |||||||||
| No internal communication error in CMC-08 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "H" (CMC-08) | P0B5E | open circuit | measured cell voltages of broken line and the next higher line in CMC-08 | = 5.6 | [V] | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | |
| CMC-08 error memory status flag | valid | |||||||||
| No internal communication error in CMC-08 | ||||||||||
| Hybrid/EV Battery Voltage Sensor "H" (CMC-08) | P0B5F | circuit range/performance (rationality check high) | difference between sum of all cell voltages in CMC-08 and ASIC voltage of CMC-08 | > 1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-08 and mean value (ASIC voltage of CMC-08 divided by number of cells in CMC-08) | > 1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Hybrid/EV Battery Voltage Sensor "H" (CMC-08) | P0B5F | circuit range/performance (rationality check low) | difference between sum of all cell voltages in CMC-08 and ASIC voltage of CMC-08 | < -1 | [V] | BECM mode | = AC_CHARGING | 500 [ms] continuous | 2 DCY | |
| OR | OR | |||||||||
| difference between any cell voltage in CMC-08 and mean value (ASIC voltage of CMC-08 divided by number of cells in CMC-08) | < -1 | [V] | BECM mode | = EMERGENCY_OFF | ||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_ON | |||||||||
| Cell Module Controller (CMC) - Communication Monitoring | ||||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| CMC-01: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-01 error memory status flag | valid | |||||||||
| CMC-02: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-02 error memory status flag | valid | |||||||||
| CMC-03: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-03 error memory status flag | valid | |||||||||
| CMC-04: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-04 error memory status flag | valid | |||||||||
| CMC-05: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-05 error memory status flag | valid | |||||||||
| CMC-06: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-06 error memory status flag | valid | |||||||||
| CMC-07: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-07 error memory status flag | valid | |||||||||
| CMC-08: Communication | U0111 | lost communication with Battery Energy Control Module "A" | message time out | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-08 error memory status flag | valid | |||||||||
| CMC-01: Communication | P0DAF | Hybrid/EV Battery Cell Balancing Circuit "A" | Bus-Off error of CMC-01 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-01 error memory status flag | valid | |||||||||
| CMC-02: Communication | P0DB3 | Hybrid/EV Battery Cell Balancing Circuit "B" | Bus-Off error of CMC-02 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-02 error memory status flag | valid | |||||||||
| CMC-03: Communication | P0DB7 | Hybrid/EV Battery Cell Balancing Circuit "C" | Bus-Off error of CMC-03 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-03 error memory status flag | valid | |||||||||
| CMC-04: Communication | P0DBB | Hybrid/EV Battery Cell Balancing Circuit "D" | Bus-Off error of CMC-04 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-04 error memory status flag | valid | |||||||||
| CMC-05: Communication | P0DBF | Hybrid/EV Battery Cell Balancing Circuit "E" | Bus-Off error of CMC-05 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-05 error memory status flag | valid | |||||||||
| CMC-06: Communication | P0DC3 | Hybrid/EV Battery Cell Balancing Circuit "F" | Bus-Off error of CMC-06 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-06 error memory status flag | valid | |||||||||
| CMC-07: Communication | P0DC7 | Hybrid/EV Battery Cell Balancing Circuit "G" | Bus-Off error of CMC-07 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-07 error memory status flag | valid | |||||||||
| CMC-08: Communication | P0DCB | Hybrid/EV Battery Cell Balancing Circuit "H" | Bus-Off error of CMC-08 CAN controller | detected | Battery CAN communication | active | 1.5 [s] continuous | 0 DCY | ||
| CMC-08 error memory status flag | valid | |||||||||
| Battery Energy Control Module (BECM) - Performance Monitoring | ||||||||||
| BECM: State of charge window monitoring | P057F | state of charge window monitoring as per CCR J1968.2 | CASE 1: first monitoring cycle after changing from HV_OFF to HV_ON and driving cycle identified | BECM mode | = HV_ON | CASE 1: | 2 DCY | |||
| State of charge starts above the upper limit and stays outside | > 95 | [%] | 650 [s] once / DCY | |||||||
| OR | ||||||||||
| State of charge starts below the lower limit and stays outside | < 15 | [%] | CASE 2: | |||||||
| CASE 2: second and following monitoring cycles | 5 [s] continuous | |||||||||
| State of charge starts above the upper limit and stays outside | > 95 | [%] | ||||||||
| OR | ||||||||||
| State of charge starts below the lower limit and stays outside | < 15 | [%] | ||||||||
| BECM: Performance monitoring based on resistance | P0A80 | performance check as per CCR J1968.2 (based on resistance) on battery level | ratio between calculated battery resistance and Begin-Of-Life (BOL) resistance | > 2 | average cell temperatures | < 50 | [°C] | 500 [s] continuous | 2 DCY | |
| > -5 | [°C] | |||||||||
| deviation between maximum and minimum cell temperature | < 10 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| battery current | < -20 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.1 | [-] | ||||||||
| gradient of battery current | < -1 | [A/100ms] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-01: Performance Check based on capacity | P0A7F | performance check as per CCR J1968.2 (based on capacity) for CMC01 | calculated capacity for CMC01 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-02: Performance Check based on capacity | P0EDD | performance check as per CCR J1968.2 (based on capacity) for CMC02 | calculated capacity for CMC02 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-03: Performance Check based on capacity | P0EDE | performance check as per CCR J1968.2 (based on capacity) for CMC03 | calculated capacity for CMC03 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-04: Performance Check based on capacity | P0EDF | performance check as per CCR J1968.2 (based on capacity) for CMC04 | calculated capacity for CMC04 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-05: Performance Check based on capacity | P0EE0 | performance check as per CCR J1968.2 (based on capacity) for CMC05 | calculated capacity for CMC05 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-06: Performance Check based on capacity | P0EE1 | performance check as per CCR J1968.2 (based on capacity) for CMC06 | calculated capacity for CMC06 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-07: Performance Check based on capacity | P2CCC | performance check as per CCR J1968.2 (based on capacity) for CMC07 | calculated capacity for CMC07 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-08: Performance Check based on capacity | P2CCD | performance check as per CCR J1968.2 (based on capacity) for CMC08 | calculated capacity for CMC08 | < 27.636 | [Ah] | OCV-conditions fulfilled: | 500 [ms] continuous | 2 DCY | ||
| battery current | < 1...3 | [A] | ||||||||
| for time | = 7, 200...600 | [s] | ||||||||
| runtime/EEPROM data are | valid | [-] | ||||||||
| difference of SOC between current and ultimate OCV measurement | ≥ 60 | [%] | ||||||||
| time between current and ultimate OCV measurement | < 4 | [days] | ||||||||
| max. worst CASE Ah-accounting error | < 2 | [%] | ||||||||
| CMC-01: Performance Check | P0A7F | performance check as per CCR J1968.2 (based on resistance) for CMC01 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-02: Performance Check | P0EDD | performance check as per CCR J1968.2 (based on resistance) for CMC02 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-03: Performance Check | P0EDE | performance check as per CCR J1968.2 (based on resistance) for CMC03 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-04: Performance Check | P0EDF | performance check as per CCR J1968.2 (based on resistance) for CMC04 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-05: Performance Check | P0EE0 | performance check as per CCR J1968.2 (based on resistance) for CMC05 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-06: Performance Check | P0EE1 | performance check as per CCR J1968.2 (based on resistance) for CMC06 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-07: Performance Check | P2CCC | performance check as per CCR J1968.2 (based on resistance) for CMC07 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-08: Performance Check | P2CCD | performance check as per CCR J1968.2 (based on resistance) for CMC08 | ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance | > 2 | battery current for cell selection | < -100 | [A] | 500 [s] continuous | 2 DCY | |
| average cell temperatures | < 50 | [°C] | ||||||||
| > -5 | [°C] | |||||||||
| deviation between max. and min. cell temperature | < 5 | [°C] | ||||||||
| battery current for calculation | < 0 | [A] | ||||||||
| count of calculation ratios | = 100 | [-] | ||||||||
| difference of minimum and maximum ratio between calculated resistance and begin of life resistance within a calculation set | ≤ 0.15 | [-] | ||||||||
| time after cell selection | ≥ 1.5 | [s] | ||||||||
| time after ECU startup | ≥ 1.5 | [s] | ||||||||
| CMC-01: Balancing Check | P0DAC | balancing check per CCR J1968.2 for CMC01 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-02: Balancing Check | P0DB0 | balancing check per CCR J1968.2 for CMC02 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-03: Balancing Check | P0DB4 | balancing check per CCR J1968.2 for CMC03 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR |
Table continues below
| Component/System | Fault Code (SAE-Code) | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illumination | ||
|---|---|---|---|---|---|---|---|---|---|---|
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-04: Balancing Check | P0DB8 | balancing check per CCR J1968.2 for CMC04 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-05: Balancing Check | P0DBC | balancing check per CCR J1968.2 for CMC05 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-06: Balancing Check | P0DC0 | balancing check per CCR J1968.2 for CMC06 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-07: Balancing Check | P0DC4 | balancing check per CCR J1968.2 for CMC07 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| CMC-08: Balancing Check | P0DC8 | balancing check per CCR J1968.2 for CMC08 | | amount of electric charge of each cell - average amount of electric charge of all cells | | ≥ 4 | [Ah] | (BECM mode | = HV_OFF | 500 [ms] continuous | 2 DCY | |
| OR | ||||||||||
| BECM mode) | = LOCAL_ACTIVE | |||||||||
| absolute battery current | < 5 | [A] | ||||||||
| OCV recovery time | ≥ 11, 000...330 | [s] | ||||||||
| cell state of charge | > 30 | [%] | ||||||||
| Battery Charger Control Module (BCCM) - Component errors | ||||||||||
| BCCM: Invalid Diagnostic Information | U113A | error memory status flag check | BCCM error memory status flag | not valid | (BECM mode | = AC_CHARGING | 2.5 [s] continuous | 2 DCY | ||
| OR | ||||||||||
| BECM mode | = EMERGENCY_OFF | |||||||||
| OR | ||||||||||
| BECM mode | = HV_OFF | |||||||||
| OR | ||||||||||
| BECM mode) | = HV_ON | |||||||||
| Hybrid CAN communication | active | |||||||||