| 1 |
- PERFORM: Preliminary Check to verify the customers concern. Refer to
.
-- Was Complaint verified? |
-- YES:
-- NO:
- GATHER more information from customer about the complaint.
|
| 2 |
- IGNITION: OFF.
- DISCONNECT: Motronic Engine Control Module Power Supply Relay -J271- from the Fuse Panel B -SB- in the engine compartment (refer to appropriate wiring diagram).
- IGNITION: ON.
- CHECK: Motronic Engine Control Module Power Supply Relay -J271- socket terminals 1/86 and 5/87 to ground for voltage.
- IGNITION: OFF.
- SPECIFIED VALUE: Battery voltage.
-- Were Values obtained? |
-- YES:
-- NO:
- PERFORM: Visual Inspection of wiring and component.
- CHECK: Wiring for open, high resistance, short or harness connector for damage, corrosion, loose or broken terminals.
- REPAIR: Faulty wiring or connector.
- GO TO: Step 6.
|
| 3 |
- REMOVE: Engine/Motor Control Module - J623-. Refer to appropriate Service Information.
- CONNECT: Jumper wire, between the Motronic Engine Control Module Power Supply Relay -J271- socket terminals 5/87 and 3/30.
- IGNITION: ON.
- CHECK: Engine/Motor Control Module -J623- harness connector T91 / 5 and T91 / 6 to ground for voltage.
- IGNITION: OFF.
- SPECIFIED VALUE: Battery voltage.
-- Were Values obtained? |
-- YES:
-- NO:
|
| 4 |
- REMOVE: Jumper wire, between the Motronic Engine Control Module Power Supply Relay -J271- socket terminals 5/87 and 3/30.
- CHECK: Motronic Engine Control Module Power Supply Relay -J271- socket terminal 2/85 to the Engine/Motor Control Module -J623- harness connector T91 / 7 for resistance.
- SPECIFIED VALUE: 0.5 Ω (± 0.3 Ω).
-- Was Value obtained? |
-- YES:
- REPLACE: Motronic Engine Control Module Power Supply Relay -J271-. Refer to appropriate Service Information.
- GO TO: Step 6.
-- NO:
- PERFORM: Visual Inspection of wiring and component.
- CHECK: Wiring for open, high resistance, short or harness connector for damage, corrosion, loose or broken terminals.
- REPAIR: Faulty wiring or connector.
- GO TO: Step 6.
|
| 5 |
- REMOVE: Jumper wire, between the Motronic Engine Control Module Power Supply Relay -J271- socket terminals 5/87 and 3/30.
- REMOVE: Appropriate Fuse (refer to appropriate wiring diagram for correct fuse).
- CHECK: Downstream (output) side of Appropriate Fuse to the Engine/Motor Control Module -J623- harness connector T91 / 5 and T91 / 6 for resistance (refer to appropriate wiring diagram for correct fuse).
- SPECIFIED VALUE: 0.5 Ω (± 0.3 Ω).
-- Were Values obtained? |
-- YES:
- REPLACE: Fuse Panel B -SB- fuse box. Refer to appropriate Service Information.
- GO TO: Step 6.
-- NO:
- PERFORM: Visual Inspection of wiring and component.
- CHECK: Wiring for open, high resistance, short or harness connector for damage, corrosion, loose or broken terminals.
- REPAIR: Faulty wiring or connector.
- GO TO: Step 6.
|
| 6 |
- Final Procedure
- Perform a road test to verify repair.
-- Does the original DTC return? |
-- YES:
- CHECK: Engine/Motor Control Module -J623- harness connector for any damaged, pushed-out pins.
- REPAIR: As necessary.
- If all electrical connections are OK:
- REPLACE: Engine/Motor Control Module -J623-. Refer to appropriate Service Information.
- Clear the DTC's. Refer to
.
- Repair is complete. Generate Readiness Code. Refer to
.
- Return vehicle to Customer.
-- NO:
- Perform the diagnostic procedure for any DTC's.
- If no DTC's return, the repair is complete.
- Return vehicle to customer.
|