Home >> Audi >> 2023 >> A8 Quattro >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool CWGD,DECA,CZSE,DCBD,DWNB,DWLA,DWPA,DWKA,DWRP,DLZA,DKMB (General Information) >> St Generic Scan Tool >> Description And Operation >> Evaporative Emission System >> Natural Vacuum Leak Detection (NVLD) EVAP System
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Natural Vacuum Leak Detection (NVLD) EVAP System

The system utilizes an engine-off natural vacuum evaporative system integrity check that tests for leaks with a diameter of 0.020 inch while the engine is off and the ignition is off. The natural vacuum leak detection (NVLD) evaporative system integrity check uses a pressure switch to detect evaporative system leaks. The correlation between the pressure and the temperature in a sealed system is used to generate a vacuum in the tank when the temperature drops. If a sufficient temperature drop is detected for a minimum time period, the vacuum level in a sealed system will exceed the threshold to close the NVLD pressure switch. Therefore, if the switch does not close under these conditions, a leak is detected. If the switch closes, the system is considered to be leak-free.