Home >> Audi >> 2025 >> Q5 e Premium Plus >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Generic Scan Tool (DSMA) (Battery Energy Control Module DTC Tables) >> St Generic Scan Tool >> Diagnosis And Testing >> Battery Energy Control Module DTC Tables >> Battery Energy Control Module (BECM) --, 2025 MY
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Battery Energy Control Module (BECM) --, 2025 MY

Component/System DTC / DTC Description Monitor Strategy Description Malfunction Criteria Threshold Value   Secondary Parameters Enable Condition   Monitoring Time Length MIL Illum.
BECM: Performance (Self Test) P0A1F - Battery Energy Control Module "A" Performance internal hardware check CPU test OR RAM test OR ROM test failed failed failed         5 [ms] On Mode Change (except to EMERGENCY_OFF or LOCAL_ACTIVE) 0 DCY
BECM: Internal Control Module P0604 - Internal Control Module Random Access Memory (RAM) Error Random Acces Memory (RAM) check secured internal data exchange failed         5 [ms] continuous 0 DCY
P062F - Internal Control Module EEPROM Error EEPROM check memory checksum error detected         1 [sec] multiple 0 DCY
BECM: Hybrid CAN Controller P163E - Faulty control module CAN RAM check read/write check in hybrid CAN-RAM failed   BECM mode = INIT   5 [ms] once / DCY 0 DCY
BECM: Battery CAN Controller CAN RAM check read/write check in battery CAN-RAM failed   BECM mode = INIT   5 [ms] once / DCY 0 DCY
BECM: Control Module Processor P0606 - Control Module Processor watchdog reset watchdog reset occured         5 [ms] continuous 0 DCY
BECM: Control Module U3001 - Control Module Improper Shutdown Performance improper shutdown performance incorrect BECM postrun execution (aborted or not started) at least one OBD-relevant monitoring 5 times in a row failed and pending   BECM mode = INIT   150 [ms] once / DCY 0 DCY
BECM: Battery Monitor Module - Daisy Chain Input P058D - Battery Monitor Module "A" Voltage Monitoring Performance voltage monitoring performance (short to battery) CASE 1:     (BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT active valid   2 [sec] continuous 0 DCY
  ratio of BECM Daisy Chain input voltage to battery voltage > 0.9 [-]      
        BECM mode    
  CASE 2: BECM Daisy Chain input voltage Critical overvoltage/undervoltage condition of any cell voltage > 4 reported [V] BECM mode    
        BECM mode    
        BECM mode) Battery CAN communication error memory status flags of all CMCs    
voltage monitoring performance (short to ground) BECM Daisy Chain input voltage < 4 [V] (BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT active valid   2 [sec] continuous 0 DCY
  No critical overvoltage/undervoltage condition of any cell voltage reported        
        BECM mode    
        BECM mode    
        BECM mode    
        BECM mode) Battery CAN communication error memory status flags of all CMCs    
BECM: Battery Monitor Module - Daisy Chain Output voltage monitoring performance (short to battery) BECM Daisy Chain output voltage > 4 [V] (BECM mode BECM mode BECM mode BECM mode BECM mode) BECM Daisy Chain output target value = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT = 0 [-] 5 [sec] continuous 0 DCY
voltage monitoring performance (short to ground) BECM Daisy Chain output voltage < 4 [V] (BECM mode BECM mode BECM mode BECM mode BECM mode) BECM Daisy Chain output target value = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT = 1 [-] 5 [sec] continuous 0 DCY
BECM: Internal Control Module - Hardware Disable Output P0E2D - Internal Control Module Hybrid/EV Battery Monitor Performance hybrid/EV battery monitor performance (short to battery) Hardware-Disable output voltage > 10 [V] (BECM mode BECM mode BECM mode BECM mode BECM mode) BECM HW Disable output target value = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT = 0 [-] 5 [sec] continuous 0 DCY
hybrid/EV battery monitor performance (short to ground) Hardware-Disable output voltage < 4 [V] (BECM mode BECM mode BECM mode BECM mode BECM mode) BECM HW Disable output target value = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT = 1 [-] 5 [sec] continuous 0 DCY
BECM: High-Voltage System Interlock P0A0D - High Voltage System Interlock Circuit "A" High circuit "A" high (short to battery) voltage drop across shunt > 5 [V]       500 [ms] continuous 0 DCY
P0A0C - High Voltage System Interlock Circuit "A" Low circuit "A" low (short to ground) voltage drop across shunt < 0.2 [V]       500 [ms] continuous 0 DCY
P0A0A - High Voltage System Interlock Circuit "A" HV interlock implausible HV interlock loop current < 8 [mA]       50 [ms] continuous 0 DCY
  OR        
  HV interlock loop current > 12 [mA]    
P0A0B - High Voltage System Interlock Circuit "A" Performance performance (internal circuit) Value measured by HV interlock ADC with input signal set to ground level (0 V) > 51.57 [mV] (BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   500 [ms] continuous 0 DCY
  OR Value measured by HV interlock ADC with input signal set to reference voltage (3.3 V) OR HV Interlock ADC values for time <3248.43 not received 10 [mV] [ms] BECM mode BECM mode    
        BECM mode    
        BECM mode)    
BECM: Control Module Power Off Timer P262B - Control Module Power Off Timer Performance plausibility check A - MAX check (rationality check high) CASE 1: 0.06 * actual postrun timer AND actual postrun timer - HV off hardware timer value CASE 2: 0.06 * actual postrun timer AND ratio of HV off hardware timer value to actual postrun time ≤ 1 ≥ 1 > 1 ≥ 1.06 [sec] [sec] [sec] [-] BECM mode HV Supply for time = RUN_ON switched off ≥ 5 [sec] 0 [sec] once / DCY 2 DCY
plausibility check A - MIN check (rationality check low) CASE 1: 0.06 * actual postrun timer AND HV off hardware timer value - actual postrun timer CASE 2: 0.06 * actual postrun timer AND ratio of HV off hardware timer value to actual postrun time ≤ 1 ≥ 1 > 1 ≤ 0.94 [sec] [sec] [sec] [-] BECM mode HV Supply for time = RUN_ON switched off ≥ 5 [sec] 0 [sec] once / DCY 2 DCY
plausibility check B - MIN check (rationality check low) ratio of HV off hardware timer value to last stored internal postrun time ≤ 0.94 [-] BECM mode = INIT   0 [sec] once / DCY 2 DCY
plausibility check C (internal circuit) Response from HV Off Hardware Timer circuit during initialization OR Response from HV Off Hardware Timer circuit not received invalid         40 [ms] once / DCY 2 DCY
BECM: Production Mode P0610 - Control Module Vehicle Options Error vehicle in production mode production mode active   for activation: max mileage since initial vehicle start-up < 100 [km] 5 [sec] once / DCY 0 DCY
BECM: OBD Settings Incompatible P064F - Unauthorized Software/Calibration Detected compatibility check internal OBD settings and vehicle OBD settings not compatible   valid message containing vehicle OBD settings received   2.9 [sec] continuous 0 DCY
Hybrid/EV Battery Pack Coolant Pump Supply Voltage P0C4D - Hybrid/EV Battery Pack Coolant Pump Supply Voltage Circuit High circuit high supply voltage @ coolant pump > 0.4 [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   5 [sec] continuous 2 DCY
P0C4C - Hybrid/EV Battery Pack Coolant Pump Supply Voltage Circuit Low circuit low ratio of supply voltage @ coolant pump to 12V supply voltage < 0.9 [-] coolant pump (BECM mode BECM mode BECM mode BECM mode) switched on = AC_CHARGING OR = EMERGENCY_OFF OR HV_OFF OR = HV_ON   5 [sec] continuous 2 DCY
Hybrid/EV Battery Pack Coolant Pump "A" Control P0C49 - Hybrid/EV Battery Pack Coolant Pump "A" Control Circuit High circuit high time duration of high signal sent by pump ≥ 10 [sec] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   5 [sec] continuous 2 DCY
P0C48 - Hybrid/EV Battery Pack Coolant Pump "A" Control Circuit Low circuit low time duration of ground signal sent by pump ≥ 2 [sec] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   5 [sec] continuous 2 DCY
P0C47 - Hybrid/EV Battery Pack Coolant Pump "A" Control Circuit/Open circuit open (functional check: timeout) alive signal (PWM signal) missing         39.5 [sec] continuous 2 DCY
Hybrid/EV Battery Pack Coolant Pump "A" P0C4A - Hybrid/EV Battery Pack Coolant Pump "A" Control Performance performance (functional check: dry run) time duration of ground signal sent by pump AND pause time between ground signal sent by pump > 900 <1100 > 900 <1100 [ms] [ms] [ms] [ms] coolant pump pump timeout monitoring PWM duty cycle commanded on passed > 85 % 7.2 [sec] continuous 2 DCY
Hybrid/EV Battery Pack Coolant Pump P0CFF - Hybrid/EV Battery Pack Coolant Pump "A" Stuck/Stalled functional check: stuck/stalled time duration of ground signal sent by pump AND pause time between ground signal sent by pump >1400 < 1600 > 900 <1100 [ms] [ms] [ms] [ms] coolant pump pump timeout monitoring PWM duty cycle commanded on passed > 25 % 21 [sec] continuous 2 DCY
Hybrid/EV Battery Pack Coolant Pump "A" P0C4A - Hybrid/EV Battery Pack Coolant Pump "A" Control Performance performance (functional check: overheating) time duration of ground signal sent by pump AND pause time between ground signal sent by pump >1900 < 2100 > 900 <1100 [ms] [ms] [ms] [ms] coolant pump pump timeout monitoring commanded on passed   8.2 [sec] continuous 2 DCY
Coolant Temperature Sensor at HV Battery Inlet P0C45 - Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit High circuit high (short to battery) signal value of temperature voltage @ HV battery inlet > 3248.44 [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0C44 - Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit Low circuit low (short to ground) signal value of temperature voltage @ HV battery inlet < 48.34 [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0C42 - Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit open circuit signal value of temperature voltage @ HV battery inlet > 3125.98 < 3158.20 [mV] [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0C44 - Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit Low circuit low (out of range low) signal value of temperature voltage @ HV battery inlet > 48.34 < 325.48 [mV] [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0C45 - Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit High circuit high (out of range high) signal value of temperature voltage @ HV battery inlet OR signal value of temperature voltage @ HV battery inlet > 3019.63 < 3125.98 > 3158.20 < 3248.44 [mV] [mV] [mV] [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0C43 - Hybrid/EV Battery Pack Coolant Temperature Sensor "A" Circuit Range/Performance range/performance (rationality high) difference between coolant temperature @ HV battery inlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≥ 15•••21 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT [min] 1.5 [sec] continuous 2 DCY
range/performance (rationality low) difference between coolant temperature @ HV battery inlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≤ -15...-21 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT [min] 1.5 [sec] continuous 2 DCY
Coolant Temperature Sensor at HV Battery Outlet P0CD8 - Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit High circuit high (short to battery) signal value of temperature voltage @ HV battery outlet > 3248.44 [mV] BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR   5 [sec] continuous 2 DCY
        BECM mode BECM mode BECM mode = HV_OFF OR = HV_ON OR = INIT      
P0CD7 - Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit Low circuit low (short to ground) signal value of temperature voltage @ HV battery outlet < 48.34 [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0CD5 - Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit open circuit signal value of temperature voltage @ HV battery outlet > 3125.98 < 3158.20 [mV] [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0CD7 - Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit Low circuit low (out of range low) signal value of temperature voltage @ HV battery outlet > 48.34 < 325.48 [mV] [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0CD8 - Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit High circuit high (out of range high) signal value of temperature voltage @ HV battery outlet OR signal value of temperature voltage @ HV battery outlet > 3019.63 < 3125.98 > 3158.20 < 3248.44 [mV] [mV] [mV] [mV] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   5 [sec] continuous 2 DCY
P0CD6 - Hybrid/EV Battery Pack Coolant Temperature Sensor "B" Circuit Range/Performance range/performance (rationality high) difference between coolant temperature @ HV battery outlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≥ 15•••21 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT [min] 2 [sec] continuous 2 DCY
range/performance (rationality low) difference between coolant temperature @ HV battery outlet and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≤ -15...-21 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT [min] 2 [sec] continuous 2 DCY
Coolant Temperature at Chiller P0CEF - Hybrid/EV Electronics Coolant Temperature Sensor "A" Circuit Range/Perfomance range/performance (rationality high) difference between pump coolant temperature and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≥ 15•••21 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT [min] 2.2 [sec] continuous 2 DCY
range/performance (rationality low) difference between pump coolant temperature and median value of the coolant temperatures @ HV battery inlet, HV battery outlet and pump coolant temperature ≤ -15...-21 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT [min] 2.2 [sec] continuous 2 DCY
BJB State Monitoring P33F0 - High-voltage system activation Malfunction change to HV_ON fails BJB mode != HV_ON   BJB target mode = HV_ON   1 [sec] continuous 0 DCY
change to AC_CHARGING fails BJB mode != AC_CHARGING   BJB target mode = AC_CHARGING   1 [sec] continuous 0 DCY
P33F1 - High-voltage system deactivation Malfunction change to HV_OFF fails BJB mode != HV_OFF OR != EMERGENCY_OFF OR != INIT   BJB target mode = HV_OFF   1 [sec] continuous 0 DCY
P33F0 - High-voltage system activation Malfunction emergency shutoff BJB mode = EMERGENCY_OFF   BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   1 [sec] continuous 0 DCY
BECM: High Voltage Service Disconnect Open P0B37 - High Voltage Service Disconnect Open Service Disconnect opened service disconnect not closed   BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT   100 [ms] continuous 0 DCY
BECM: Hybrid/EV Battery Charging Current P0CA6 - Hybrid/EV Battery Charging Current High charging current high measured HV battery charge current > 0•••218 [A] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = PRECHARGE   1 [sec] continuous 0 DCY
BECM: Hybrid/EV Battery Discharging Current P0CA7 - Hybrid/EV Battery Discharging Current High discharging current high measured HV battery discharge current > 0...395 [A] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = PRECHARGE   1 [sec] continuous 0 DCY
BECM: Hybrid/EV Battery Pack Over Temperature P0A7E - Hybrid/EV Battery Pack "A" Over Temperature BJB temperature too high critical BJB temperature > 124 [°C] BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR   5 [sec] continuous 0 DCY
        BECM mode = HV_ON      
BJB: Hybrid/EV Battery Pack Over Temperature BJB temperature too high CASE 1: shunt 1 temperature CASE 2: shunt 2 temperature CASE 3: main board temperature CASE 4: MCU junction temperature > 130 > 130 ≥ 130 ≥ 140 [°C] [°C] [°C] [°C]       CASE 1 to 3: 10.5 [sec] continuous CASE 4: 5.5 [sec] continuous 0 DCY
BECM: Hybrid/EV Battery Pack Over Temperature CMC temperature too high any temperature @ CMC01 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC02 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC03 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC04 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC05 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC06 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC07 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
CMC temperature too high any temperature @ CMC08 > 65 [°C] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 0 DCY
BECM: Hybrid/EV Battery System Voltage P0AFB - Hybrid/EV Battery System Voltage High system voltage high pack voltage signal > 448 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   1 [sec] continuous 0 DCY
P0AFA - Hybrid/EV Battery System Voltage Low system voltage low pack voltage signal < 187 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   1 [sec] continuous 0 DCY
BECM: Hybrid/EV Battery State Of Charge P0B29 - Hybrid/EV Battery "B" Voltage Low state of charge low level 2 state of charge < 3 [%] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [sec] continuous 0 DCY
P0A80 - Replace Hybrid/EV Battery Pack state of charge low level 3 state of charge ≤ 0 [%] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [sec] continuous 0 DCY
BECM: Recharging Performance P1B16 - Charging hybrid battery no external charge detected recharging current too low state of charge AND charging current < 6 < 2 [%] [A] BECM mode BECM mode = AC_CHARGING OR = HV_ON   30 [min] continuous 0 DCY
Hybrid/EV Battery Interface Control Module "A" (CMC-01) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-01 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-01 < 1.85 [V] BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF   100 [ms] continuous 0 DCY
        BECM mode BECM mode BECM mode OR = HV_ON OR = INIT OR = PRECHARGE      
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-01 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "B" (CMC-02) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-02 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-02 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-02 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "C" (CMC-03) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-03 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-03 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-03 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "D" (CMC-04) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-04 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-04 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-04 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "E" (CMC-05) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-05 > 4.25 [V] BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR   100 [ms] continuous 0 DCY
        BECM mode BECM mode BECM mode BECM mode = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE      
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-05 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-05 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "F" (CMC-06) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-06 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-06 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-06 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "G" (CMC-07) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-07 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-07 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-07 > 0.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   500 [ms] continuous 2 DCY
Hybrid/EV Battery Interface Control Module "H" (CMC-08) P0B26 - Hybrid/EV Battery "A" Voltage High cell voltage high any cell voltage signal within CMC-08 > 4.25 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0B25 - Hybrid/EV Battery "A" Voltage Low cell voltage low any cell voltage signal within CMC-08 < 1.85 [V] BECM mode BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   100 [ms] continuous 0 DCY
P0BBD - Hybrid/EV Battery Pack Voltage Variation Exceeded Limit cell voltage rationality check difference between maximum cell voltage and minimum cell voltage within CMC-08 > 0.25 [V] BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF   500 [ms] continuous 2 DCY
        BECM mode BECM mode BECM mode BECM mode OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE      
BECM: Daisy Chain Redundant Safety Shutdown P0AF8 - Hybrid/EV Battery System Voltage redundant safety shutdown due to cell overvoltage/undervoltage BECM Daisy Chain input < 4 [V] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = PRECHARGE   500 [ms] continuous 0 DCY
BJB: Main Fuse P0A95 - High Voltage Fuse "A" rationality check deviation between battery voltage and voltage at main fuse < 60 [V] time after ECU wakeup valid message from BJB > 500 received [ms] 1.5 [sec] continuous 0 DCY
BJB: Battery Charger Fuse P0E2E - Battery Charger "A" Fuse rationality check voltage at battery charger fuse < 60 [V] time after ECU wakeup valid message from BJB > 500 received [ms] 1.5 [sec] continuous 2 DCY
BECM: Vehicle System - 12 Volt Supply Voltage P0563 - System Voltage High system voltage high power supply voltage > 17 [V]       9 [sec] continuous 0 DCY
U1401-Function restriction due to excessive voltage system voltage high power supply voltage > 17 [V]       10 [ms] continuous 0 DCY
P0562 - System Voltage Low system voltage low power supply voltage < 8 [V]       9 [sec] continuous 0 DCY
U1400-Function restriction Function restriction due to low voltage system voltage low power supply voltage < 8 [V]       10 [ms] continuous 0 DCY
system voltage pre-low power supply voltage < 9 [V]       10 [ms] continuous 0 DCY
BECM: Crash Detection P1609 - Crash shut-off was triggered crash shut-off was triggered crash detected   System active   0 [ms] continuous 0 DCY
BECM: Reversible Crash Detection P168A - Reversible crash shut-off was triggered reversible crash shut-off was triggered reversible crash detected   System active   0 [ms] continuous 2 DCY
Hybrid CAN U0028 - Vehicle Communication Bus A vehicle communication bus A CAN controller enters "BUS OFF" state 3 times in a row   time after ECU wakeup > 500 [ms] 450 [ms] continuous 0 DCY
U0029 - Vehicle Communication Bus A Performance vehicle communication bus A performance CAN messages not received   time after ECU wakeup > 500 [ms] 450 [ms] continuous 0 DCY
Hybrid CAN: Engine Control Module (ECM) U0100 - Lost Communication With ECM/PCM "A" lost communication with ECM/PCM "A" message timeout detected   time after ECU wakeup FlexRay > 500 active [ms] 5 [sec] continuous 0 DCY
lost communication with ECM/PCM "A" message timeout detected   time after ECU wakeup FlexRay > 500 active [ms] 800 [ms] continuous 0 DCY
lost communication with ECM/PCM "A" message timeout detected   time after ECU wakeup FlexRay > 500 active [ms] 2 [sec] continuous 2 DCY
U0401 - Invalid Data Received From ECM/PCM "A" invalid data received from ECM/PCM "A" message counter error detected   time after ECU wakeup valid message from ECM > 500 received [ms] 8 [sec] continuous 0 DCY
invalid data received from ECM/PCM "A" checksum error detected   time after ECU wakeup valid message from ECM > 500 received [ms] 2.5 [sec] continuous 0 DCY
invalid data received from ECM/PCM "A" received message implausible message   time after ECU wakeup valid message from ECM > 500 received [ms] 5 [sec] continuous 2 DCY
Hybrid CAN: Body Control Module "A" U0141 - Lost Communication With Body Control Module "A" lost communication with Body Control Module "A" message timeout detected   time after ECU wakeup ComfortCAN > 500 active [ms] 1 [sec] continuous 0 DCY
U0431 - Invalid Data Received From Body Control Module "A" invalid data received from ECM/PCM "A" message counter error detected   time after ECU wakeup ComfortCAN > 500 active [ms] 1 [sec] continuous 0 DCY
invalid data received from ECM/PCM "A" checksum error detected   time after ECU wakeup ComfortCAN > 500 active [ms] 200 [ms] continuous 0 DCY
Hybrid CAN: Gateway "A" U0146 - Lost Communication With Serial Data Gateway Module "A" lost communication with Gateway "A" message timeout detected   (BECM mode BECM mode BECM mode BECM mode) time after ECU wakeup any Hybrid CAN message = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON > 500 received [ms] 1 [sec] continuous 0 DCY
U0447 - Invalid Data Received From Serial Data Gateway Module "A" invalid data received from Gateway "A" message counter error detected   time after ECU wakeup valid message from Gateway > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Gateway "A" checksum error detected   time after ECU wakeup valid message from Gateway > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Gateway "A" BECM target mode BECM target mode BECM target mode != AC_CHARGING != HV_OFF != HV_ON   time after ECU wakeup valid message from Gateway > 500 received [ms] 2 [sec] continuous 0 DCY
Hybrid CAN: Battery Charger Control Module (BCCM) U019B - Lost Communication With Battery Charger Control Module "A" lost communication with Battery Charger Control Module "A" message timeout detected   time after ECU wakeup Hybrid CAN communication > 500 active [ms] 5 [sec] continuous 2 DCY
Hybrid CAN: Coolant Temperature Control Module U0116 - Lost Communication With Coolant Temperature Control Module lost communication with Coolant Temperature Control Module message timeout detected   time after ECU wakeup Hybrid CAN communication > 500 active [ms] 1 [sec] continuous 2 DCY
lost communication with Coolant Temperature Control Module message timeout detected   time after ECU wakeup Hybrid CAN communication > 500 active [ms] 5 [sec] continuous 2 DCY
U0456 - Invalid Data Received From Coolant Temperature Control Module invalid data received from Coolant Temperature Control Module received message implausible message   time after ECU wakeup valid message from VTMC > 500 received [ms] 5 [sec] continuous 2 DCY
Battery CAN U0037 - Vehicle Communication Bus B vehicle communication bus B CAN controller enters "BUS OFF" state 3 times in a row   time after ECU wakeup > 500 [ms] 10 [ms] continuous 0 DCY
U0038 - Vehicle Communication Bus B Performance vehicle communication bus B performance (global timeout) CAN messages not received   time after ECU wakeup CMC power supply > 500 active [ms] 450 [ms] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Pack Sensor Module U029A - Lost Communication With Hybrid/EV Battery Pack Sensor Module lost communication with Hybrid/EV Battery Pack Sensor Module (BJB) message timeout detected   time after ECU wakeup any Battery CAN message > 500 received [ms] 500 [ms] continuous 0 DCY
U059B - Invalid Data Received From Hybrid/EV Battery Pack Sensor Module invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) message counter error detected   time after ECU wakeup valid message from BJB > 500 received [ms] 500 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) checksum error detected   time after ECU wakeup valid message from BJB > 500 received [ms] 20 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) received message implausible   time after ECU wakeup valid message from BJB > 500 received [ms] 800 [ms] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "A" U01A0 - Lost Communication with Hybrid/EV Battery Interface Control Module "A" lost communication with Hybrid/EV Battery Interface Control Module "A" (CMC-01) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U04A1 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "A" invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) message counter error detected   time after ECU wakeup valid message from CMC-01 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) checksum error detected   time after ECU wakeup valid message from CMC-01 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "A" (CMC-01) received message implausible   time after ECU wakeup valid messsage from CMC-01 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "B" U01A1 - Lost Communication with Hybrid/EV Battery Interface Control Module "B" lost communication with Hybrid/EV Battery Interface Control Module "B" (CMC-02) message timeout detected   time after ECU wakeup > 500 [ms] 1 [sec] continuous 0 DCY
        CMC power supply active      
U04A2 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "B" invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) message counter error detected   time after ECU wakeup valid message from CMC-02 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) checksum error detected   time after ECU wakeup valid message from CMC-02 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "B" (CMC-02) received message implausible   time after ECU wakeup valid messsage from CMC-02 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "C" U01A2 - Lost Communication with Hybrid/EV Battery Interface Control Module "C" lost communication with Hybrid/EV Battery Interface Control Module "C" (CMC-03) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U04A3 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "C" invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) message counter error detected   time after ECU wakeup valid message from CMC-03 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) checksum error detected   time after ECU wakeup valid message from CMC-03 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "C" (CMC-03) received message implausible   time after ECU wakeup valid messsage from CMC-03 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "D" U01A3 - Lost Communication with Hybrid/EV Battery Interface Control Module "D" lost communication with Hybrid/EV Battery Interface Control Module "D" (CMC-04) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U02A0 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "D" invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) message counter error detected   time after ECU wakeup valid message from CMC-04 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) checksum error detected   time after ECU wakeup valid message from CMC-04 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "D" (CMC-04) received message implausible   time after ECU wakeup valid messsage from CMC-04 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "E" U01A4 - Lost Communication with Hybrid/EV Battery Interface Control Module "E" lost communication with Hybrid/EV Battery Interface Control Module "E" (CMC-05) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U04A5 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "E" invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) message counter error detected   time after ECU wakeup valid message from CMC-05 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) checksum error detected   time after ECU wakeup valid message from CMC-05 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "E" (CMC-05) received message implausible   time after ECU wakeup valid messsage from CMC-05 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "F" U01A5 - Lost Communication with Hybrid/EV Battery Interface Control Module "F" lost communication with Hybrid/EV Battery Interface Control Module "F" (CMC-06) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U04A6 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "F" invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) message counter error detected   time after ECU wakeup valid message from CMC-06 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) checksum error detected   time after ECU wakeup valid message from CMC-06 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "F" (CMC-06) received message implausible   time after ECU wakeup valid messsage from CMC-06 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "G" U01A6 - Lost Communication with Hybrid/EV Battery Interface Control Module "G" lost communication with Hybrid/EV Battery Interface Control Module "G" (CMC-07) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U04A7 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "G" invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) message counter error detected   time after ECU wakeup valid message from CMC-07 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) checksum error detected   time after ECU wakeup valid message from CMC-07 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "G" (CMC-07) received message implausible   time after ECU wakeup valid messsage from CMC-07 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Interface Control Module "H" U01A7 - Lost Communication with Hybrid/EV Battery Interface Control Module "H" lost communication with Hybrid/EV Battery Interface Control Module "H" (CMC-08) message timeout detected   time after ECU wakeup CMC power supply > 500 active [ms] 1 [sec] continuous 0 DCY
U04A8 - Invalid Data Received From Hybrid/EV Battery Interface Control Module "H" invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) message counter error detected   time after ECU wakeup valid message from CMC-08 > 500 received [ms] 1 [sec] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) checksum error detected   time after ECU wakeup valid message from CMC-08 > 500 received [ms] 200 [ms] continuous 0 DCY
invalid data received from Hybrid/EV Battery Interface Control Module "H" (CMC-08) received message implausible   time after ECU wakeup valid messsage from CMC-08 > 500 received [ms] 1 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Pack Sensor Module U059B - Invalid Data Received From Hybrid/EV Battery Pack Sensor Module invalid data received from Hybrid/EV Battery Pack Sensor Module (BJB) BJB error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "A" (CMC-01) P0DAF - Hybrid/EV Battery Cell Balancing Circuit "A" Range/Performance range/performance (invalid data) (CMC-01) CMC-01 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "B" (CMC-02) P0DB3 - Hybrid/EV Battery Cell Balancing Circuit "B" Range/Performance range/performance (invalid data) (CMC-02) CMC-02 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "C" (CMC-03) P0DB7 - Hybrid/EV Battery Cell Balancing Circuit "C" Range/Performance range/performance (invalid data) (CMC-03) CMC-03 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "D" (CMC-04) P0DBB - Hybrid/EV Battery Cell Balancing Circuit "D" Range/Performance range/performance (invalid data) (CMC-04) CMC-04 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "E" (CMC-05) P0DBF - Hybrid/EV Battery Cell Balancing Circuit "E" Range/Performance range/performance (invalid data) (CMC-05) CMC-05 error memory status flag not valid   (BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF   2.5 [sec] continuous 0 DCY
        BECM mode BECM mode) Battery CAN communication OR = HV_OFF OR = HV_ON active      
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "F" (CMC-06) P0DC3 - Hybrid/EV Battery Cell Balancing Circuit "F" Range/Performance range/performance (invalid data) (CMC-06) CMC-06 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "G" (CMC-07) P0DC7 - Hybrid/EV Battery Cell Balancing Circuit "G" Range/Performance range/performance (invalid data) (CMC-07) CMC-07 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
Battery CAN: Hybrid/EV Battery Cell Balancing Circuit "H" (CMC-08) P0DCB - Hybrid/EV Battery Cell Balancing Circuit "H" Range/Performance range/performance (invalid data) (CMC-08) CMC-08 error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Battery CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 0 DCY
BJB: Internal Harwdare Check (Self Test) P0AFC - Hybrid/EV Battery Pack Sensor Module internal hardware check (self test) CASE 1: current measurement test current measurement values CASE 2: voltage measurement test voltage measurement values CASE 3: contactor supply voltage monitoring redundant measurement of contactor supply voltage < 0 > 450 invalid not equal [A] [A] Battery CAN communication BJB error memory status flag Additionally for CASE 1 & 2: BJB mode Additionally for CASE 3: BJB mode active valid = AC_CHARGING OR = EMRGENCY_OFF OR = HV_OFF OR = HV_ON OR = PRECHARGE = INIT   CASE 1: 580 [ms] continous CASE 2 & 3: 600 [ms] once / DCY 0 DCY
BJB: Internal Memory RAM check error correcting code (ECC) failure detected   Battery CAN communication BJB error memory status flag active valid   500 [ms] once / DCY 0 DCY
BJB: EEPROM EEPROM check memory checksum error detected   Battery CAN communication BJB error memory status flag BJB mode active valid = INIT   500 [ms] once / DCY 0 DCY
BJB: FlashEEPROM FlashEEPROM check memory checksum error detected   Battery CAN communication BJB error memory status flag BJB mode active valid = INIT   500 [ms] once / DCY 0 DCY
BJB: Hardware Disable Malfunction plausibility check value of Hardware Disable path 1 and value of Hardware Disable path 2 not equal   Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   580 [ms] continous 0 DCY
BJB: Hardware Disable Line P0E2D - Internal Control Module Hybrid/EV Battery Monitor Performance performance (out of range high) measured voltage > 28.6 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   515 [ms] continuous 0 DCY
performance (open circuit) actual value of Hardware-Disable state = disable   target value of Hardware-Disable state = enable   600 [ms] continuous 0 DCY
BJB: Hybrid/EV Battery Pack Current Sensor "A" P0AC2 - Hybrid/EV Battery Pack Current Sensor "A" Circuit High circuit high CASE 1: Short to battery status of measurement chip 1 or status of measurment chip 2 or status of both measurement chips CASE 2: Out of range high measured current open circuit open circuit open circuit > 600 [A] Battery CAN communication BJB error memory status flag active valid   510 [ms] continuous 0 DCY
P0AC1 - Hybrid/EV Battery Pack Current Sensor "A" Circuit Low circuit low measured current < -600 [A] Battery CAN communication BJB error memory status flag active valid   510 [ms] continuous 0 DCY
P0AC0 - Hybrid/EV Battery Pack Current Sensor "A" Circuit Range/Performance circuit range/performance (internal hardware check) CASE 1: measurement configuration of shunt hardware CASE 2: calibration data of shunt hardware CASE 3: startup time current and voltage gauge CASE 4: heartbeat monitoring CASE 5: message timeout between gauge and BJB OR memory checksum error between gauge and BJB OR message counter error between gauge and BJB CASE 6: shunt temperature plausibility check invalid invalid exceeded invalid detected detected detected invalid   Battery CAN communication BJB error memory status flag Additionally for CASE 2 & 3: BJB mode Additionally for CASE 4: BJB mode Additionally for CASE 5 & 6: BJB mode active valid = INIT = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGING = INIT OR = PRECHARGING   CASE 1 : 501 [ms] continuous CASE 2: 500 [ms] once / DCY CASE 3: 820 [ms] once / DCY CASE 4 & 5: 510 [ms] continuous CASE 6: 10.5 [s] continuous 0 DCY
BJB: Hybrid/EV Battery Pack Current Sensors "A" and "B" P0B13 - Hybrid/EV Battery Pack Current Sensor "A"/"B" Correlation rationality check CASE 1: battery current ≤ 100 A deviation between measured shunt current 1 and measured shunt current 2 CASE 2: battery current > 100 A deviation between measured shunt current 1 and measured shunt current 2 > 2.6 > 2.6 [A] [%] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARHING OR = HV_OFF   900 [ms] continuous 0 DCY
          OR = HV_ON OR = INIT OR = PRECHARGE      
BJB: Temperature Sensors P0AFC - Hybrid/EV Battery Pack Sensor Module circuit high CASE 1: short to battery ADC digital value of T1 or ADC digital value of shunt NTC 1 (T3) OR NTC2(T4) CASE 2: out of range high measured temperature @ T1 OR measured temperature @ shunt NTC 1 (T3) OR measured temperature @ shunt NTC 2 (T4) ≥ 3, 800 > 64, 000 > 170 > 150 > 150 [-] [-] [°C] [°C] [°C] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   1.5 [s] continuous 2 DCY
circuit low CASE 1: short to ground ADC digital value of T1 or ADC digital value of shunt NTC 1 (T3) OR NTC2(T4) CASE 2: out of range low measured temperature @ T1 OR measured temperature @ shunt NTC 1 (T3) OR measured temperature @ shunt NTC 2 (T4) ≤ 10 < 1, 500 < -40 < -35 < -35 [-] [-] [°C] [°C] [°C] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   1.5 [s] continuous 2 DCY
rationality check high difference between single temperature of any BJB temperature sensor and median value of all BJB temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 1 [sec] continuous 2 DCY
rationality check low difference between single temperature of any BJB temperature sensor and median value of all BJB temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 1 [sec] continuous 2 DCY
BJB: Hybrid/EV Battery Pack Voltage Sense "A" P0ABD - Hybrid/EV Battery Pack Voltage Sense "A" Circuit High circuit high CASE 1: short to battery measured voltage CASE 2: out of range high measured voltage ≥ 815.7 > 500 [V] [V] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   510 [ms] continuous 0 DCY
BJB: Hybrid/EV Battery Pack Voltage Sense "A" BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor P0ABC - Hybrid/EV Battery Pack Voltage Sense "A" Circuit Low circuit low CASE 1: short to ground measured voltage CASE 2: out of range low measured voltage difference between battery voltage and sum of all cell voltages < 0 < 100 > 40 [V] [V] [V] Battery CAN communication BJB error memory status flag BJB mode BECM mode BECM mode BECM mode BECM mode BECM mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = PRECHARGE   510 [ms] continuous 500 [ms] continuous 0 DCY 0 DCY
P0ABB - Hybrid/EV Battery Pack Voltage Sense "A" Circuit Range/Performance circuit range/performance (rationality check high)
BJB: Hybrid/EV Battery Pack Voltage Sensor "A" - Battery Voltage Positive Terminal Sensor circuit range/performance (rationality check low) difference between battery voltage and sum of all cell voltages < -40 [V] BECM mode BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = PRECHARGE   500 [ms] continuous 0 DCY
BJB: Hybrid/EV Battery Pack Voltage Sense "B" - System Voltage Positive Terminal Sensor P0B17 - Hybrid/EV Battery Pack Voltage Sense "B" Circuit High circuit high measured system voltage @ positive terminal > 914 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   510 [ms] continuous 0 DCY
P0B16 - Hybrid/EV Battery Pack Voltage Sense "B" Circuit Low circuit low measured system voltage @ positive terminal < -547 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   510 [ms] continuous 0 DCY
BJB: Hybrid/EV Battery Pack Voltage Sense "B" - System Voltage Negative Terminal Sensor P0B17 - Hybrid/EV Battery Pack Voltage Sense "B" Circuit High circuit high measured system voltage @ negative terminal > 914 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR   510 [ms] continuous 0 DCY
P0B17 - Hybrid/EV Battery Pack Voltage Sense "B" Circuit High           = HV_ON OR = INIT OR = PRECHARGE      
P0B16 - Hybrid/EV Battery Pack Voltage Sense "B" Circuit Low circuit low measured system voltage @ negative terminal < -547 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = AC_CHARGING OR = HV_OFF OR = HV_ON OR = INIT OR = PRECHARGE   510 [ms] continuous 0 DCY
BJB: Hybrid/EV Battery Pack Voltage Sensor "B" P0B15 - Hybrid/EV Battery Pack Voltage Sense "B" Circuit Range/Performance circuit range/performance (rationality check high) difference between system voltage and battery voltage > 40 [V] BECM mode BECM mode = AC_CHARGING OR = HV_ON   2 [sec] continuous 0 DCY
circuit range/performance (rationality check low) difference between system voltage and battery voltage < -40 [V] BECM mode BECM mode = AC_CHARGING OR = HV_ON   2 [sec] continuous 0 DCY 0 DCY
BJB: Sensor Power Supply "B" P06B5 - Sensor Power Supply "B" Circuit High circuit high measured voltage > 26.3 [V] Battery CAN communication BJB error memory status flag active valid   510 [ms] continuous 2 DCY
P06B4 - Sensor Power Supply "B" Circuit Low circuit low measured voltage < 5.6 [V] Battery CAN communication BJB error memory status flag active valid   510 [ms] continuous 2 DCY
BJB: High-Voltage Service Disconnect P0B36 - High Voltage Service Disconnect Circuit High circuit high measured voltage > 24.3 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = INIT OR = PRECHARGE   510 [ms] continuous 0 DCY
P0B35 - High Voltage Service Disconnect Circuit Low circuit low measured voltage < 6.0 [V] Battery CAN communication BJB error memory status flag BJB mode active valid = INIT OR = PRECHARGE   510 [ms] continuous 0 DCY
BJB: Hybrid/EV Battery Positive Main Contactor Circuit P0AA1 - Hybrid/EV Battery Positive Contactor "A" Stuck Closed stuck closed deviation between battery voltage and system positive voltage < |5| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = HV_OFF OR = EMERGENCY_OFF   6 [s] multiple 0 DCY
P0AA2 - Hybrid/EV Battery Positive Contactor "A" Stuck Open stuck open deviation between battery voltage and system positive voltage > |10| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = PRECHARGE   600 [ms] multiple 0 DCY
BJB: Hybrid/EV Battery Negative Main Contactor Circuit P0AA4 - Hybrid/EV Battery Negative Contactor "A" Stuck Closed stuck closed system negative voltage < |10| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = HV_OFF OR = EMERGENCY_OFF   6 [s] multiple 0 DCY
P0AA5 - Hybrid/EV Battery Negative Contactor "A" Stuck Open stuck open system negative voltage > |3| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = PRECHARGE   530 [ms] multiple 0 DCY
BJB: Hybrid/EV Battery Precharge Contactor Circuit P0AE2 - Hybrid/EV Battery Precharge Contactor Circuit Stuck Closed stuck closed deviation between battery voltage and system positive voltage < |5| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = HV_OFF OR = EMERGENCY_OFF   6 [s] multiple 0 DCY
P0AE3 - Hybrid/EV Battery Precharge Contactor Circuit Stuck Open stuck open deviation between battery voltage and system positive voltage > |10| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = PRECHARGE   600 [ms] multiple 0 DCY
BJB: Hybrid/EV Battery Positive Main Contactor Control P0AD9 - Hybrid/EV Battery Positive Contactor Control Circuit/Open circuit open CASE 1: high side on, low side off ratio of the contactor supply voltage and the actually applied contactor voltage CASE 2: high side off, low side on ratio of contactor supply voltage and actually applied contactor voltage < 0.828 > 0.0912 [-] [-] Battery CAN communication BJB error memory status flag BJB mode Contactor supply voltage active valid = INIT > 6 < 28.5 [V] [V] 550 [ms] once / DCY 0 DCY
P0ADC - Hybrid/EV Battery Positive Contactor "A" Control Circuit High circuit high CASE 1: short to battery ratio of contactor supply voltage and actually applied contactor voltage CASE 2: coil current out of range high coil current > 0.828 > 914 [-] [mA] Battery CAN communication BJB error memory status flag Additionally for CASE 1: BJB mode Contactor supply voltage Additionally for CASE 2: BJB mode Contactor driver active valid = INIT > 6 < 28.5 = AC_CHARGING OR = HV_ON OR = PRECHARGE activated [V] [V] CASE 1: 550 [ms] once / DCY CASE 2: 1.5 [s] continous 0 DCY
P0ADB - Hybrid/EV Battery Positive Contactor "A" Control Circuit Low circuit low CASE 1: short to ground ratio of contactor supply voltage and actually applied contactor voltage CASE 2: coil current out of range low coil current > 0.0912 < 748 [-] [mA] Battery CAN communication BJB error memory status flag Additionally for CASE 1: BJB mode Contactor supply voltage Additionally for CASE 2: BJB mode Contactor driver active valid = INIT > 6 < 28.5 = AC_CHARGING OR = HV_ON OR = PRECHARGE activated [V] [V] CASE 1: 550 [ms] once / DCY CASE 2: 510 [ms] continous 0 DCY
BJB: Hybrid/EV Battery Negative Main Contactor Control P0ADD - Hybrid/EV Battery Negative Contactor Control Circuit/Open functional check (open circuit) CASE 1: high side on, low side off ratio of the contactor supply voltage and the actually applied contactor voltage CASE 2: high side off, low side on ratio of contactor supply voltage and actually applied contactor voltage < 0.828 > 0.0912 [-] [-] Battery CAN communication BJB error memory status flag BJB mode Contactor supply voltage active valid = INIT > 6 < 28.5 [V] [V] 550 [ms] once / DCY 0 DCY
P0AE0 - Hybrid/EV Battery Negative Contactor "A" Control Circuit High circuit high CASE 1: short to battery ratio of contactor supply voltage and actually applied contactor voltage CASE 2: coil current out of range high coil current > 0.828 > 914 [-] [mA] Battery CAN communication BJB error memory status flag Additionally for CASE 1: BJB mode Contactor supply voltage active valid = INIT > 6 < 28.5 [V] [V] CASE 1: 550 [ms] once / DCY CASE 2: 1.5 [s] continous 0 DCY
P0AE0 - Hybrid/EV Battery Negative Contactor "A" Control Circuit High         Additionally for CASE 2: BJB mode Contactor driver = AC_CHARGING OR = HV_ON OR = PRECHARGE activated      
P0ADF - Hybrid/EV Battery Negative Contactor "A" Control Circuit Low circuit low CASE 1: short to ground ratio of contactor supply voltage and actually applied contactor voltage CASE 2: coil current out of range low coil current > 0.0912 < 748 [-] [mA] Battery CAN communication BJB error memory status flag Additionally for CASE 1: BJB mode Contactor supply voltage Additionally for CASE 2: BJB mode Contactor driver active valid = INIT > 6 < 28.5 = AC_CHARGING OR = HV_ON OR = PRECHARGE activated [V] [V] CASE 1: 550 [ms] once / DCY CASE 2: 510 [ms] continous 0 DCY
BJB: Hybrid/EV Battery Precharge Contactor Control P0AE4 - Hybrid/EV Battery Precharge Contactor Control Circuit "A" Open functional check (open circuit) CASE 1: high side on, low side off ratio of the contactor supply voltage and the actually applied contactor voltage CASE 2: high side off, low side on ratio of contactor supply voltage and actually applied contactor voltage < 0.828 > 0.0912 [-] [-] Battery CAN communication BJB error memory status flag BJB mode Contactor supply voltage active valid = INIT > 6 < 28.5 [V] [V] 550 [ms] once / driving cycle 0 DCY
P0AE7 - Hybrid/EV Battery Precharge Contactor Control Circuit "A" High circuit high CASE 1: short to battery ratio of contactor supply voltage and actually applied contactor voltage CASE 2: coil current out of range high coil current > 0.828 > 2.689 [-] [A] Battery CAN communication BJB error memory status flag Additionally for CASE 1: BJB mode Contactor supply voltage Additionally for CASE 2: BJB mode active valid = INIT > 6 < 28.5 = PRECHARGE [V] [V] CASE 1: 550 [ms] once / DCY CASE 2: 550 [ms] continous 0 DCY
P0AE6 - Hybrid/EV Battery Precharge Contactor Control Circuit "A" Low circuit low ratio of contactor supply voltage and actually applied contactor voltage > 0.0912 [-] Battery CAN communication BJB error memory status flag BJB mode Contactor supply voltage active valid = INIT > 6 < 28.5 [V] [V] 550 [ms] once / driving cycle 0 DCY
BJB: Precharging System P0CA7 - Hybrid/EV Battery Discharging Current High discharging current high measured current within > |12| 80 [A] [ms] Battery CAN communication BJB error memory status flag BJB mode active valid = PRECHARGE   510 [ms] multiple 0 DCY
P0C78 - Hybrid/EV Battery System Precharge "A" Time Too Long functional check: precharge time too long deviation between battery voltage and system voltage > |10| [V] Battery CAN communication BJB error memory status flag BJB mode active valid = PRECHARGE   1 [s] multiple 0 DCY
P1B15 - Hybrid Battery Precharge Resistance Excess Temperature functional check: precharge failed precharge counter > 300 [-] BECM mode Battery CAN communication BJB error memory status flag = PRECHARGE active valid   500 [ms] continuous 0 DCY 0 DCY
BJB: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Contrl Module "A" CASE 1: message timeout CASE 2: message counter error CASE 3: checksum error detected detected detected   Battery CAN communication BJB error memory status flag BJB mode Additionally for CASE 2 & 3: message from BECM active valid = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON OR = INIT OR =PRECHARGE received   CASE 1: 1.6 [s] continuous CASE 2: 500 [ms] continuous CASE 3: 1.5 [s] continous 0 DCY
CMC-01: Battery Monitoring Chip P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-01 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-01 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY 0 DCY
CMC-01: Configuration P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A" data integrity check checksum error detected   Battery CAN communication CMC-01 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-01: Alarm Signaling P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-01 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-01: Internal Memory P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-01: Power Supply P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 [V] [V] [V] Battery CAN communication CMC-01 error memory status flag active valid   1 [sec] continuous 0 DCY
P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A"     OR > 2.6 [V]          
CMC-02: Battery Monitoring Chip P0DB0 - Hybrid/EV Battery Cell Balancing Circuit "B" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-02 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-02 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY 0 DCY
CMC-02: Configuration P0DB0 - Hybrid/EV Battery Cell Balancing Circuit "B" data integrity check checksum error detected   Battery CAN communication CMC-02 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-02: Alarm Signaling P0DB0 - Hybrid/EV Battery Cell Balancing Circuit "B" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-02 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-02: Internal Memory P0DB0 - Hybrid/EV Battery Cell Balancing Circuit "B" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-02: Power Supply P0DB0 - Hybrid/EV Battery Cell Balancing Circuit "B" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-02 error memory status flag active valid   1 [sec] continuous 0 DCY
CMC-03: Battery Monitoring Chip P0DB4 - Hybrid/EV Battery Cell Balancing Circuit "C" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-03 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-03 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY 0 DCY
CMC-03: Configuration P0DB4 - Hybrid/EV Battery Cell Balancing Circuit "C" data integrity check checksum error detected   Battery CAN communication CMC-03 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-03: Alarm Signaling P0DB4 - Hybrid/EV Battery Cell Balancing Circuit "C" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-03 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-03: Internal Memory P0DB4 - Hybrid/EV Battery Cell Balancing Circuit "C" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-03: Power Supply P0DB4 - Hybrid/EV Battery Cell Balancing Circuit "C" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-03 error memory status flag active valid   1 [sec] continuous 0 DCY
CMC-04: Battery Monitoring Chip P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-04 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-04 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 0 DCY
P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D"   window comparator (digital) functionality check failed         500 [ms] once/DCY  
CMC-04: Configuration P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D" data integrity check checksum error detected   Battery CAN communication CMC-04 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-04: Alarm Signaling P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-04 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-04: Internal Memory P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-04: Power Supply P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-04 error memory status flag active valid   1 [sec] continuous 0 DCY
CMC-05: Battery Monitoring Chip P0DBC - Hybrid/EV Battery Cell Balancing Circuit "E" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-05 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-05 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY 0 DCY
CMC-05: Configuration P0DBC - Hybrid/EV Battery Cell Balancing Circuit "E" data integrity check checksum error detected   Battery CAN communication CMC-05 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-05: Alarm Signaling P0DBC - Hybrid/EV Battery Cell Balancing Circuit "E" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-05 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-05: Internal Memory P0DBC - Hybrid/EV Battery Cell Balancing Circuit "E" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-05: Power Supply P0DBC - Hybrid/EV Battery Cell Balancing Circuit "E" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-05 error memory status flag active valid   1 [sec] continuous 0 DCY
CMC-06: Battery Monitoring Chip P0DC0 - Hybrid/EV Battery Cell Balancing Circuit "F" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-06 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-06 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY 0 DCY
CMC-06: Configuration P0DC0 - Hybrid/EV Battery Cell Balancing Circuit "F" data integrity check checksum error detected   Battery CAN communication CMC-06 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-06: Alarm Signaling P0DC0 - Hybrid/EV Battery Cell Balancing Circuit "F" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-06 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-06: Internal Memory P0DC0 - Hybrid/EV Battery Cell Balancing Circuit "F" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-06: Power Supply P0DC0 - Hybrid/EV Battery Cell Balancing Circuit "F" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-06 error memory status flag active valid   1 [sec] continuous 0 DCY
CMC-07: Battery Monitoring Chip P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor > |100| [mV] CASE 1 to 4: Battery CAN communication active   CASE 1 : 1 [sec] continous 0 DCY
P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G"   CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [V] [V] [V] [°C] CMC-07 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-07 error memory status flag valid = INIT active valid   CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY  
CMC-07: Configuration P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G" data integrity check checksum error detected   Battery CAN communication CMC-07 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-07: Alarm Signaling P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-07 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-07: Internal Memory P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-07: Power Supply P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-07 error memory status flag active valid   1 [sec] continuous 0 DCY
CMC-08: Battery Monitoring Chip P0DC8 - Hybrid/EV Battery Cell Balancing Circuit "H" internal hardware check CASE 1: difference between cell voltage measured by battery monitoring chip and cell voltage measured by main processor CASE 2: failed communication attempts between main processor and battery monitoring chip CASE 3: battery monitoring chip internal reference voltage CASE 4: difference between sampled values of auxiliary ADC-inputs with and without internal pullup resistors activated CASE 5: battery monitoring chip internal temperature CASE 6: window comparator (analog) functionality check CASE 7: window comparator (digital) functionality check > |100| ≥ 20 > 4.75 < 4.25 > 4.5 ≥ 140 failed failed [mV] [V] [V] [V] [°C] CASE 1 to 4: Battery CAN communication CMC-08 error memory status flag CASE 5 to 7: BECM mode Battery CAN communication CMC-08 error memory status flag active valid = INIT active valid   CASE 1 : 1 [sec] continous CASE 2: 600 [ms] continous CASE 3: 500 [ms] continous CASE 4: 5.5 [sec] continous CASE 5: 1.5 [sec] once/DCY CASE 6: 500 [ms] once/DCY CASE 7: 500 [ms] once/DCY 0 DCY
CMC-08: Configuration P0DC8 - Hybrid/EV Battery Cell Balancing Circuit "H" data integrity check checksum error detected   Battery CAN communication CMC-08 error memory status flag active valid   600 [ms] continuous 0 DCY
CMC-08: Alarm Signaling P0DC8 - Hybrid/EV Battery Cell Balancing Circuit "H" internal hardware check CASE 1: main processor daisy chain output battery monitoring chip alarm line readback CASE 2: alarm input pin and out pin high state threshold alarm input pin and out pin low state threshold < 2 > 2 > 3.75 < 2.25 [V] [V] [V] [V] Battery CAN communication CMC-08 error memory status flag active valid   CASE 1: 550 [ms] continuous CASE 2: 1 [sec] continuous 0 DCY
CMC-08: Internal Memory P0DC8 - Hybrid/EV Battery Cell Balancing Circuit "H" RAM/ROM check read/write-check in RAM OR ROM checksum error OR Flash memory error correction code error 5 errors detected during driving cycle 5 errors detected during driving cycle 5 errors detected during driving cycle   Battery CAN communication CMC-01 error memory status flag active valid   500 [ms] continuous 0 DCY
CMC-08: Power Supply P0DC8 - Hybrid/EV Battery Cell Balancing Circuit "H" out of range battery monitoring chip power supply voltage OR battery monitoring chip reference voltage < 16 OR > 58.5 < 2.4 OR > 2.6 [V] [V] [V] [V] Battery CAN communication CMC-08 error memory status flag active valid   1 [sec] continuous 0 DCY
Hybrid/EV Battery Temperature Sensor "A" (CMC-01) P0A9D - Hybrid/EV Battery Temperature Sensor "A" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-01 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0A9E - Hybrid/EV Battery Temperature Sensor "A" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-01 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0A9C - Hybrid/EV Battery Temperature Sensor "A" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-01 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0A9C - Hybrid/EV Battery Temperature Sensor "A" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-01 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR [min] 2.7 [sec] continuous 2 DCY
P0A9C - Hybrid/EV Battery Temperature Sensor "A" Circuit Range/Performance         BECM mode) = RUN_ON      
Hybrid/EV Battery Temperature Sensor "B" (CMC-02) P0AC7 - Hybrid/EV Battery Temperature Sensor "B" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-02 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0AC8 - Hybrid/EV Battery Temperature Sensor "B" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-02 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0AC6 - Hybrid/EV Battery Temperature Sensor "B" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-02 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0AC6 - Hybrid/EV Battery Temperature Sensor "B" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-02 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Temperature Sensor "C" (CMC-03) P0ACC - Hybrid/EV Battery Temperature Sensor "C" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-03 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0ACD - Hybrid/EV Battery Temperature Sensor "C" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-03 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0ACB - Hybrid/EV Battery Temperature Sensor "C" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-03 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0ACB - Hybrid/EV Battery Temperature Sensor "C" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-03 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Temperature Sensor "D" (CMC-04) P0AEA - Hybrid/EV Battery Temperature Sensor "D" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-04 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0AEB - Hybrid/EV Battery Temperature Sensor "D" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-04 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0AE9 - Hybrid/EV Battery Temperature Sensor "D" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-04 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0AE9 - Hybrid/EV Battery Temperature Sensor "D" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-04 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Temperature Sensor "E" (CMC-05) P0BC4 - Hybrid/EV Battery Temperature Sensor "E" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-05 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0BC5 - Hybrid/EV Battery Temperature Sensor "E" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-05 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0BC3 - Hybrid/EV Battery Temperature Sensor "E" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-05 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0BC3 - Hybrid/EV Battery Temperature Sensor "E" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-05 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Temperature Sensor "F" (CMC-06) P0C35 - Hybrid/EV Battery Temperature Sensor "F" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-06 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0C36 - Hybrid/EV Battery Temperature Sensor "F" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-06 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0C34 - Hybrid/EV Battery Temperature Sensor "F" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-06 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0C34 - Hybrid/EV Battery Temperature Sensor "F" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-06 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Temperature Sensor "G" (CMC-07) P0C7E - Hybrid/EV Battery Temperature Sensor "G" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-07 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0C7F - Hybrid/EV Battery Temperature Sensor "G" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-07 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0C7D - Hybrid/EV Battery Temperature Sensor "G" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-07 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0C7D - Hybrid/EV Battery Temperature Sensor "G" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-07 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Temperature Sensor "H" (CMC-08) P0C83 - Hybrid/EV Battery Temperature Sensor "H" Circuit Low circuit low (temperature high) CASE 1: short to ground measured cell temperature (internal OR external sensor) CASE 2: out of range high measured cell temperature (internal OR external sensor) > 120 > 86 ≤ 120 [°C] [°C] [°C] CASE 1 & 2: Battery CAN communication CMC-08 error memory status flag active valid   CASE 1 & 2: 5.5 [sec] continuous 0 DCY
P0C84 - Hybrid/EV Battery Temperature Sensor "H" Circuit High circuit high (temperature low) measured cell temperature (internal OR external sensor) < -40 [°C] Battery CAN communication CMC-08 error memory status flag active valid   5.5 [sec] continuous 0 DCY
P0C82 - Hybrid/EV Battery Temperature Sensor "H" Circuit Range/Performance circuit range/performance (temperature rationality check high) difference between cell internal temperature of CMC-08 and median value of all cell temperatures ≥ 8...15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
P0C82 - Hybrid/EV Battery Temperature Sensor "H" Circuit Range/Performance circuit range/performance (temperature rationality check low) difference between cell internal temperature of CMC-08 and median value of all cell temperatures ≤ -8...-15 [°C] HV off time calculations status HV off time (BECM mode BECM mode BECM mode BECM mode BECM mode) time calculated ≥ 360...720 = EMERGENCY_OFF OR = HV_OFF OR = INIT OR = LOCAL_ACTIVE OR = RUN_ON [min] 2.7 [sec] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-01) P0B3E - Hybrid/EV Battery Voltage Sense "A" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-01 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-01 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-01 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B3D - Hybrid/EV Battery Voltage Sense "A" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-01 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-01 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-01 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-01) P0B3B - Hybrid/EV Battery Voltage Sense "A" Circuit open circuit deviation between CMC-01 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-01 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "A" (CMC-01) P0B3C - Hybrid/EV Battery Voltage Sense "A" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-01 and ASIC voltage of CMC-01 OR difference between any cell voltage in CMC-01 and mean value (ASIC voltage of CMC-01 divided by number of cells in CMC-01) Application Specific Integrated Circuit > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B3C - Hybrid/EV Battery Voltage Sense "A" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-01 and ASIC voltage of CMC-01 OR difference between any cell voltage in CMC-01 and mean value (ASIC voltage of CMC-01 divided by number of cells in CMC-01) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-02) P0B43 - Hybrid/EV Battery Voltage Sense "B" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-02 OR > 4.95 [V] CASE 1 & 2: Battery CAN communication CMC-02 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B43 - Hybrid/EV Battery Voltage Sense "B" Circuit High   module voltage CASE 2: out of range high any measured cell voltage in CMC-02 OR module voltage > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V]          
P0B42 - Hybrid/EV Battery Voltage Sense "B" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-02 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-02 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-02 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-02) P0B40 - Hybrid/EV Battery Voltage Sense "B" Circuit open circuit deviation between CMC-02 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-02 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "B" (CMC-02) P0B41 - Hybrid/EV Battery Voltage Sense "B" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-02 and ASIC voltage of CMC-02 OR difference between any cell voltage in CMC-02 and mean value (ASIC voltage of CMC-02 divided by number of cells in CMC-02) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B41 - Hybrid/EV Battery Voltage Sense "B" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-02 and ASIC voltage of CMC-02 OR difference between any cell voltage in CMC-02 and mean value (ASIC voltage of CMC-02 divided by number of cells in CMC-02) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-03) P0B48 - Hybrid/EV Battery Voltage Sense "C" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-03 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-03 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-03 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B47 - Hybrid/EV Battery Voltage Sense "C" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-03 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-03 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-03 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-03) P0B45 - Hybrid/EV Battery Voltage Sense "C" Circuit open circuit deviation between CMC-03 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-03 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "C" (CMC-03) P0B46 - Hybrid/EV Battery Voltage Sense "C" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-03 and ASIC voltage of CMC-03 OR difference between any cell voltage in CMC-03 and mean value (ASIC voltage of CMC-03 divided by number of cells in CMC-03) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B46 - Hybrid/EV Battery Voltage Sense "C" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-03 and ASIC voltage of CMC-03 OR difference between any cell voltage in CMC-03 and mean value (ASIC voltage of CMC-03 divided by number of cells in CMC-03) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-04) P0B4D - Hybrid/EV Battery Voltage Sense "D" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-04 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-04 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-04 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B4C - Hybrid/EV Battery Voltage Sense "D" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-04 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-04 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-04 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-04) P0B4A - Hybrid/EV Battery Voltage Sense "D" Circuit open circuit deviation between CMC-04 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-04 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "D" (CMC-04) P0B4B - Hybrid/EV Battery Voltage Sense "D" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-04 and ASIC voltage of CMC-04 OR difference between any cell voltage in CMC-04 and mean value (ASIC voltage of CMC-04 divided by number of cells in CMC-04) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B4B - Hybrid/EV Battery Voltage Sense "D" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-04 and ASIC voltage of CMC-04 OR difference between any cell voltage in CMC-04 and mean value (ASIC voltage of CMC-04 divided by number of cells in CMC-04) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-05) P0B52 - Hybrid/EV Battery Voltage Sense "E" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-05 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-05 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-05 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B51 - Hybrid/EV Battery Voltage Sense "E" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-05 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-05 < 0.1 < 8 < 1 ≥ 0.1 [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-05 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B51 - Hybrid/EV Battery Voltage Sense "E" Circuit Low   OR module voltage < 16 ≥ 8 [V] [V]          
Hybrid/EV Battery Voltage Sense "A" (CMC-05) P0B4F - Hybrid/EV Battery Voltage Sense "E" Circuit open circuit deviation between CMC-05 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-05 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "E" (CMC-05) P0B50 - Hybrid/EV Battery Voltage Sense "E" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-05 and ASIC voltage of CMC-05 OR difference between any cell voltage in CMC-05 and mean value (ASIC voltage of CMC-05 divided by number of cells in CMC-05) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B50 - Hybrid/EV Battery Voltage Sense "E" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-05 and ASIC voltage of CMC-05 OR difference between any cell voltage in CMC-05 and mean value (ASIC voltage of CMC-05 divided by number of cells in CMC-05) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-06) P0B57 - Hybrid/EV Battery Voltage Sense "F" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-06 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-06 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-06 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B56 - Hybrid/EV Battery Voltage Sense "F" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-06 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-06 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-06 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-06) P0B54 - Hybrid/EV Battery Voltage Sense "F" Circuit open circuit deviation between CMC-06 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-06 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "F" (CMC-06) P0B55 - Hybrid/EV Battery Voltage Sense "F" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-06 and ASIC voltage of CMC-06 OR difference between any cell voltage in CMC-06 and mean value (ASIC voltage of CMC-06 divided by number of cells in CMC-06) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B55 - Hybrid/EV Battery Voltage Sense "F" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-06 and ASIC voltage of CMC-06 OR difference between any cell voltage in CMC-06 and mean value (ASIC voltage of CMC-06 divided by number of cells in CMC-06) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-07) P0B5C - Hybrid/EV Battery Voltage Sense "G" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-07 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-07 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-07 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B5B - Hybrid/EV Battery Voltage Sense "G" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-07 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-07 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-07 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-07) P0B59 - Hybrid/EV Battery Voltage Sense "G" Circuit open circuit deviation between CMC-07 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-07 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "G" (CMC-07) P0B5A - Hybrid/EV Battery Voltage Sense "G" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-07 and ASIC voltage of CMC-07 OR difference between any cell voltage in CMC-07 and mean value (ASIC voltage of CMC-07 divided by number of cells in CMC-07) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B5A - Hybrid/EV Battery Voltage Sense "G" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-07 and ASIC voltage of CMC-07 OR difference between any cell voltage in CMC-07 and mean value (ASIC voltage of CMC-07 divided by number of cells in CMC-07) < -1 < -1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-08) P0B61 - Hybrid/EV Battery Voltage Sense "H" Circuit High circuit high CASE 1: short to battery any measured cell voltage in CMC-08 OR module voltage CASE 2: out of range high any measured cell voltage in CMC-08 OR module voltage > 4.95 > 65 > 4.5 ≤ 4.95 > 58.5 ≤ 65 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-08 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
P0B60 - Hybrid/EV Battery Voltage Sense "H" Circuit Low circuit low CASE 1: short to ground any measured cell voltage in CMC-08 OR module voltage CASE 2: out of range low any measured cell voltage in CMC-08 OR module voltage < 0.1 < 8 < 1 ≥ 0.1 < 16 ≥ 8 [V] [V] [V] [V] [V] [V] CASE 1 & 2: Battery CAN communication CMC-08 error memory status flag active valid   CASE 1 & 2: 1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sense "A" (CMC-08) P0B5E - Hybrid/EV Battery Voltage Sense "H" Circuit open circuit deviation between CMC-08 cell voltages with even and odd cell-balancing resistors activated > |152| [mV] Battery CAN communication CMC-08 error memory status flag active valid   1.1 [sec] continuous 0 DCY
Hybrid/EV Battery Voltage Sensor "H" (CMC-08) P0B5F - Hybrid/EV Battery Voltage Sense "H" Circuit Range/Performance circuit range/performance (rationality check high) difference between sum of all cell voltages in CMC-08 and ASIC voltage of CMC-08 OR difference between any cell voltage in CMC-08 and mean value (ASIC voltage of CMC-08 divided by number of cells in CMC-08) > 1 > 1 [V] [V] BECM mode BECM mode BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON   500 [ms] continuous 2 DCY
P0B5F - Hybrid/EV Battery Voltage Sense "H" Circuit Range/Performance circuit range/performance (rationality check low) difference between sum of all cell voltages in CMC-08 and ASIC voltage of CMC-08 OR difference between any cell voltage in CMC-08 and mean value (ASIC voltage of CMC-08 divided by number of cells in CMC-08) < -1 < -1 [V] [V] BECM mode BECM mode = AC_CHARGING OR = EMERGENCY_OFF OR   500 [ms] continuous 2 DCY
P0B5F - Hybrid/EV Battery Voltage Sense "H" Circuit Range/Performance         BECM mode BECM mode = HV_OFF OR = HV_ON      
CMC-01: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-01 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-02: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-02 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-03: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-03 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-04: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-04 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-05: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-05 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-06: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-06 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-07: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-07 error memory status flag active valid   1.5 [sec] continuous 0 DCY
CMC-08: Communication U0111 - Lost Communication With Battery Energy Control Module "A" lost communication with Battery Energy Control Module "A" message timeout detected   Battery CAN communication CMC-08 error memory status flag active valid   1.5 [sec] continuous 0 DCY
BECM: State of charge window monitoring P057F - Battery "A" State of Charge Performance state of charge window monitoring as per CCR J1968.2 CASE 1: first monitoring cycle after changing from HV_OFF to HV_ON and driving cycle identified State of charge starts above the upper limit and stays outside OR State of charge starts below the lower limit and stays outside CASE 2: second and following monitoring cycles State of charge starts above the upper limit and stays outside OR State of charge starts below the lower limit and stays outside > 95 < 15 > 95 < 15 [%] [%] [%] [%] BECM mode = HV_ON   CASE 1: 650 [sec] once / DCY CASE 2: 5 [sec] continuous 2 DCY
BECM: Performance monitoring based on resistance P0A80 - Replace Hybrid/EV Battery Pack performance check as per CCR J1968.2 (based on resistance) on battery level ratio between calculated battery resistance and Begin-Of-Life (BOL) resistance > 2 [-] maximum battery temperature deviation between maximum and minimum cell temperature battery current for calculation battery current count of calculation ratios maximal deviation between minimum and maximum factor in current measurement gradient of battery current time after ECU startup ≤ 50 > -5 < 10 < 0 < -20 = 100 ≤ 0.1 < -1 ≥ 1.5 [°C] [°C] [°C] [A] [A] [-] [-] [A/100ms] [sec] 500 [ms] continuous 2 DCY
CMC-01: Performance Check based on capacity P0A7F - Hybrid/EV Battery Pack "A" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC01 calculated capacity for CMC01 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-02: Performance Check based on capacity P0EDD - Hybrid/EV Battery Pack "B" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC02 calculated capacity for CMC02 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-03: Performance Check based on capacity P0EDE - Hybrid/EV Battery Pack "C" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC03 calculated capacity for CMC03 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-04: Performance Check based on capacity P0EDF - Hybrid/EV Battery Pack "D" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC04 calculated capacity for CMC04 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-05: Performance Check based on capacity P0EE0 - Hybrid/EV Battery Pack "E" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC05 calculated capacity for CMC05 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-06: Performance Check based on capacity P0EE1 - Hybrid/EV Battery Pack "F" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC06 calculated capacity for CMC06 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-07: Performance Check based on capacity P2CCC - Hybrid/EV Battery Pack "G" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC07 calculated capacity for CMC07 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-08: Performance Check based on capacity P2CCD - Hybrid/EV Battery Pack "H" Deterioration performance check as per CCR J1968.2 (based on capacity) for CMC08 calculated capacity for CMC08 < 24 [Ah] OCV-conditions fullfilled: battery current for time runtime/ EEPROM data are difference of SOC between current and ultimate OCV measurement time between current and ultimate OCV measurement max. worst case Ah-accounting error < 1...3 = 7, 200...600 valid ≥ 60 < 4 < 2 [A] [sec] [-] [%] [days] [%] 500 [ms] continuous 2 DCY
CMC-01: Performance Check P0A7F - Hybrid/EV Battery Pack "A" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC01 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-02: Performance Check P0EDD - Hybrid/EV Battery Pack "B" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC02 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-03: Performance Check P0EDE - Hybrid/EV Battery Pack "C" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC03 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-04: Performance Check P0EDF - Hybrid/EV Battery Pack "D" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC04 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-05: Performance Check P0EE0 - Hybrid/EV Battery Pack "E" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC05 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-06: Performance Check P0EE1 - Hybrid/EV Battery Pack "F" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC06 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-07: Performance Check P2CCC - Hybrid/EV Battery Pack "G" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC07 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-08: Performance Check P2CCD - Hybrid/EV Battery Pack "H" Deterioration performance check as per CCR J1968.2 (based on resistance) for CMC08 ratio between calculated cell resistance and Begin-Of-Live (BOL) resistance > 2 [-] battery current for cell selection maximum cell temperature deviation between max. and min. cell temperature battery current for calculation count of calculation ratios maximal deviation between minimum and maximum factor in current measurement time after cell selection time after ECU startup < -100 ≤ 50 > -5 < 5 < 0 = 10 ≤ 0.15 ≥ 1.5 ≥ 1.5 [A] [°C] [°C] [°C] [A] [-] [-] [sec] [sec] 500 [ms] continuous 2 DCY
CMC-01: Balancing Check P0DAC - Hybrid/EV Battery Cell Balancing Circuit "A" balancing check per CCR J1968.2 for CMC01 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-02: Balancing Check P0DB0 - Hybrid/EV Battery Cell Balancing Circuit "B" balancing check per CCR J1968.2 for CMC02 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-03: Balancing Check P0DB4 - Hybrid/EV Battery Cell Balancing Circuit "C" balancing check per CCR J1968.2 for CMC03 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-04: Balancing Check P0DB8 - Hybrid/EV Battery Cell Balancing Circuit "D" balancing check per CCR J1968.2 for CMC04 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-05: Balancing Check P0DBC - Hybrid/EV Battery Cell Balancing Circuit "E" balancing check per CCR J1968.2 for CMC05 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-06: Balancing Check P0DC0 - Hybrid/EV Battery Cell Balancing Circuit "F" balancing check per CCR J1968.2 for CMC06 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-07: Balancing Check P0DC4 - Hybrid/EV Battery Cell Balancing Circuit "G" balancing check per CCR J1968.2 for CMC07 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
CMC-08: Balancing Check P0DC8 - Hybrid/EV Battery Cell Balancing Circuit "H" balancing check per CCR J1968.2 for CMC08 | amount of electric charge of each cell - average amount of electric charge of all cells | ≥ 5 [Ah] (BECM mode BECM mode) absolute battery current for time cell state of charge = HV_OFF OR = LOCAL_ACTIVE < 5 ≥ 11, 000...330 > 30 < 95 [A] [sec] [%] [%] 500 [ms] continuous 2 DCY
BCCM: Invalid Diagnostic Information U113A-High-Voltage Battery Charger implausible message error memory status flag check BCCM error memory status flag not valid   (BECM mode BECM mode BECM mode BECM mode) Hybrid CAN communication = AC_CHARGING OR = EMERGENCY_OFF OR = HV_OFF OR = HV_ON active   2.5 [sec] continuous 2 DCY