| CAN communication |
U0146 - Lost Communication With Serial Data Gateway Module "A" |
Lost Communication With Gateway "A" (time out) |
Message time out |
|
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
5.000 |
[ms] |
2 DCY |
| |
Data length |
= invalid |
[-] |
|
|
|
|
|
|
|
| U0116 - Lost Communication With Coolant Temperature Control Module |
Lost Communication With Coolant Temperature Control Module (time out) |
Message time out |
|
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
5.000 |
[ms] |
2 DCY |
| |
Data length |
= invalid |
[-] |
|
|
|
|
|
|
|
| U0447 - Invalid Data Received From Serial Data Gateway Module "A" |
Gateway plausibility fault |
Information content |
= not plausible |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
500 |
[ms] |
2 DCY |
| U0028 - Vehicle Communication Bus A |
Vehicle Communication Bus A |
Three unsuccessful transmissions in a row |
|
[-] |
None |
None |
[-] |
other event |
n/a |
[-] |
2 DCY |
| U0029 - Vehicle Communication Bus A Performance |
Vehicle Communication Bus A Performance |
Global message time out |
|
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
450 |
[ms] |
2 DCY |
| U0447 - Invalid Data Received From Serial Data Gateway Module "A" |
Invalid data received from gateway "A" |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
150 |
[ms] |
2 DCY |
| U0456 - Invalid Data Received From Coolant Temperature Control Module |
Invalid data received from coolant temperature control module |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
1.500 |
[ms] |
2 DCY |
| Control module for pwr |
|
|
|
|
|
|
|
|
|
|
|
| electronic, output |
P33D7 - Control module for pwr electronic output module 1 internal malfunction |
Inverter U phase opened |
| U phase current DC component | |
> 70.27 |
[A] |
CPLD switching mode |
= PWM |
[-] |
Continuous |
80 |
[ms] |
1 DCY |
| module 1 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
Ignition |
= on |
[-] |
|
|
|
|
| |
|
|
|
Drive motor speed |
> 2, 500.. 5, 500 |
[rpm] |
|
|
|
|
| |
|
|
|
Drive motor torque |
> 20 |
[Nm] |
|
|
|
|
| |
|
|
|
HV voltage |
≥ 150 |
[V] |
|
|
|
|
| Inverter V phase opened |
| V phase current DC component | |
> 70.27 |
[A] |
CPLD switching mode |
= PWM |
[-] |
Continuous |
80 |
[ms] |
1 DCY |
| |
|
|
|
Ignition |
= on |
[-] |
|
|
|
|
| |
|
|
|
Drive motor speed |
> 2, 500.. 5, 500 |
[rpm] |
|
|
|
|
| |
|
|
|
Drive motor torque |
> 20 |
[Nm] |
|
|
|
|
| |
|
|
|
HV voltage |
≥ 150 |
[V] |
|
|
|
|
| Inverter W phase opened |
| W phase current DC component | |
> 70.27 |
[A] |
CPLD switching mode |
= PWM |
[-] |
Continuous |
80 |
[ms] |
1 DCY |
| |
|
|
|
Ignition |
= on |
[-] |
|
|
|
|
| |
|
|
|
Drive motor speed |
> 2, 500.. 5, 500 |
[rpm] |
|
|
|
|
| Drive motor torque |
> 20 |
[Nm] |
| HV voltage |
≥ 150 |
[V] |
| Hardware fault |
Drive motor inverter current |
> 2, 635 |
[A] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
50 |
[ms] |
1 DCY |
| |
OR |
|
|
|
|
|
|
|
|
|
| |
Drive motor inverter temperature |
> 174 |
[°C] |
|
|
|
|
|
|
|
| |
OR |
|
|
|
|
|
|
|
|
|
| |
Gate driver power supply |
< 20 |
[V] |
|
|
|
|
|
|
|
| Inverter initial HW check fault |
Inverter signal at startup |
= failed |
[-] |
HV voltage |
< 13 |
[V] |
Continuous |
50 |
[ms] |
1 DCY |
| Control module processor |
P0606 - Control Module Processor |
ECU error: ROM check |
Checksum error |
|
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| ECU error: analog digital converter check |
Error is detected in one of the following ADC tests: |
|
[-] |
None |
None |
[-] |
once / DCY |
|
|
1 DCY |
| |
Broken wire monitoring |
= failed |
|
|
|
|
|
|
| |
Pull-Down monitoring |
= failed |
|
|
|
|
|
|
| |
Converter monitoring |
= failed |
|
|
|
|
|
|
| ECU error: Program flow check |
API calling within the predetermined time |
= failed |
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| ECU error: Program flash ROM and RAM check |
Checksum error |
|
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| ECU error: Processor check |
Lock step dual core (LSDC) monitoring |
=failed |
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| ECU error: Controller RAM check |
Checksum error |
|
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| ECU error: Controller configuration register check |
Configuration register set value and its read back |
= mismatch |
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| System controller monitoring |
System bus error |
|
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| |
OR |
|
|
|
|
|
|
| |
Clock error |
|
[-] |
|
|
|
|
|
|
|
| OR |
|
| Voltage error |
[-] |
| OR |
|
| Internal watchdog error |
[-] |
| Peripheral startup monitoring |
CRC instruction error |
= detected |
[-] |
None |
None |
[-] |
once / DCY |
|
|
1 DCY |
| |
OR |
|
|
|
|
|
|
|
| |
Reset status error |
= detected |
[-] |
|
|
|
|
|
| Cyclic peripheral monitoring |
STM timer error |
= detected |
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| |
OR |
|
|
|
|
|
|
|
| |
LMU read/write check error |
= detected |
[-] |
|
|
|
|
|
| |
OR |
|
|
|
|
|
|
|
| |
Interrupt error |
= detected |
[-] |
|
|
|
|
|
| Safe Tlib SW monitoring |
Safe Tlib SW monitoring |
= failed |
[-] |
None |
None |
[-] |
once / DCY |
|
|
1 DCY |
| Bus memory / register access protection |
Illegal write access to CPU resource from other masters |
= detected |
[-] |
None |
None |
[-] |
Instantly |
|
|
1 DCY |
| External watchdog monitoring |
External watchdog timer communication |
= failed |
[-] |
None |
None |
[-] |
Continuous |
192 |
[ms] |
1 DCY |
| Shutoff path test for DCDC |
Shutoff path test for DCDC |
= failed |
[V] |
Shutoff path test monitoring |
= ready to be done |
[-] |
Continuous |
5 |
[ms] |
2 DCY |
| |
|
|
[V] |
Previous microprocessor shutdown |
= successfully |
[-] |
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
(Derating by transformer estimated temperature |
= detected |
|
|
= HvOn |
|
|
|
|
|
| Backup current plausibility fault |
OR |
|
[-] |
DCDC Current state |
OR |
[-] |
Continuous |
150 |
[ms] |
2 DCY |
| |
Derating by HV voltage) |
= detected |
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
AND |
|
|
|
|
|
|
|
|
|
| |
(| reserve current - estimated reserve current |) |
> 255 |
[A] |
|
|
|
|
|
|
|
| |
OR |
|
|
|
|
|
|
|
|
|
| (Derating by transformer estimated temperature |
|
|
| OR |
= not detected |
[-] |
| Derating by HV voltage) |
|
|
| AND |
|
|
| (| reserve current - estimated reserve current |) |
> 60.0 |
[A] |
| DCDC state plausibility fault |
Internal state comparison of safety and quality management |
= failed |
[-] |
Shut off path test |
= finished |
[-] |
Continuous |
140 |
[ms] |
2 DCY |
| |
|
|
|
Time elapse after DCDC current state or DCDC estimated state has changed |
> 1, 000 |
[ms] |
|
|
|
|
| ECU Error by Level 3 ext. Monitor |
Level 3 Shut off path test failed |
> 4 |
[-] |
None |
None |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| Control pilot |
P0CF5 - Control Pilot Circuit Low |
Circuit low |
Control pilot voltage |
< 0.038 |
[V] |
None |
None |
[-] |
Continuous |
40 |
[ms] |
1 DCY |
| P0CF3 - Control Pilot Circuit /Open |
Open circuit |
Control pilot voltage |
≥ 0.038 ≤ 2.60 |
[V] |
None |
None |
[-] |
Continuous |
50 |
[ms] |
1 DCY |
| P0CF6 - Control Pilot Circuit High |
Circuit high |
Control pilot voltage |
> 4.67 |
[V] |
None |
None |
[-] |
Continuous |
40 |
[ms] |
1 DCY |
| Out of range high |
Control pilot voltage |
≥ 3.92 |
[V] |
None |
None |
[-] |
Continuous |
50 |
[ms] |
2 DCY |
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| DC/DC converter |
P0D33 - DC/DC Converter Current High |
Current high on HV side (HW) |
HV current on HW comparator |
≥ 44.6 |
[A] |
DCDC Current state |
OR |
[-] |
Continuous |
140 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| Current high on HV side (DSP) |
HV current on DSP |
≥ 25 |
[A] |
DCDC Current state |
OR |
[-] |
Continuous |
150 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| Current high on positive LV side (HW) |
LV current on HW comparator positive |
≥ 342 |
[A] |
DCDC Current state |
OR |
[-] |
Continuous |
130 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| Current high on LV side (DSP) |
LV current on DSP |
≥ 335 |
[A] |
DCDC Current state |
OR |
[-] |
Continuous |
140 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| P0D32 - DC/DC Converter "A" Over Temperature |
Over temperature on LV side |
LV MOSFET temperature |
≥ 120 |
[°C] |
DCDC Current state |
OR |
[-] |
Continuous |
200 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| Over temperature on HV side |
HV MOSFET temperature |
≥ 130 |
[°C] |
DCDC Current state |
OR |
[-] |
Continuous |
200 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| Over temperature on transformer |
Transformer temperature |
≥ 145 |
[°C] |
DCDC Current state |
OR |
[-] |
Continuous |
200 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= HvOn |
|
|
|
|
|
| Over temperature on safety switch |
Safety switch temperature |
≥ 120 |
[°C] |
DCDC Current state |
OR |
[-] |
Continuous |
200 |
[ms] |
2 DCY |
| |
|
|
|
|
= Buck |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| P0A08 - DC/DC Converter Status Circuit |
Over voltage |
DSP Power supply voltage filtered value |
> 3.5 |
[V] |
DC/DC Converter monitoring |
= passed |
[-] |
Continuous |
20 |
[ms] |
2 DCY |
| |
|
|
|
|
= Standby |
|
|
|
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
≥ 9.8 |
[V] |
|
= HvOn |
|
|
Depends on |
|
|
| P33D0 - DC/DC converter LV output voltage low voltage |
Under voltage and reverse current on LV side |
(DCDC converter voltage sensor 2 |
and |
|
DCDC Current state |
OR |
[-] |
Continuous |
"Malfunction |
[-] |
2 DCY |
| |
|
< 10.5 |
[V] |
|
= Buck |
|
|
Criteria" |
|
|
| |
|
|
|
|
OR |
|
|
|
|
|
| |
|
|
|
|
= Error |
|
|
|
|
|
| |
AND |
|
|
LV current sensors plausibility monitoring |
= passed |
[-] |
|
|
|
|
| |
DCDC converter current sensor C |
< -10 |
[A] |
|
|
|
|
|
|
|
| |
AND |
|
|
|
|
|
|
|
|
|
| |
for a period of time) |
> 500 |
[ms] |
|
|
|
|
|
|
|
| |
OR |
|
|
|
|
|
|
|
|
|
| |
|
≥ 9.8 |
[V] |
|
|
|
|
|
|
|
| |
(DCDC converter voltage sensor C |
and |
|
|
|
|
|
|
|
|
| |
|
< 10.5 |
[V] |
|
|
|
|
|
|
|
| |
AND |
|
|
|
|
|
|
|
|
|
| |
DCDC converter current sensor C |
< -10 |
[A] |
|
|
|
|
|
|
|
| |
AND |
|
|
|
|
|
|
|
|
|
| |
for a period of time) |
> 500 |
[ms] |
|
|
|
|
|
|
|
| |
OR |
|
|
|
|
|
|
|
|
|
| |
|
≥ 8.2 |
[V] |
|
|
|
|
|
|
|
| |
(DCDC converter voltage sensor 2 |
and |
|
|
|
|
|
|
|
|
| |
|
< 9.8 |
[V] |
|
|
|
|
|
|
|
| |
AND |
|
|
|
|
|
|
|
|
|
| |
DCDC converter current sensor C |
< -10 |
[A] |
|
|
|
|
|
|
|
| |
AND |
|
|
|
|
|
|
|
|
|
| |
for a period of time) OR (DCDC converter voltage sensor C AND DCDC converter current sensor C AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor C AND for a period of time) OR (DCDC converter voltage sensor C AND DCDC converter current sensor C AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor C AND for a period of time) |
> 200 ≥ 8.2 and < 9.8 < -10 > 200 ≥ 7.5 and < 8.2 < -10 > 50 ≥ 7.5 and < 8.2 < -10 > 50 < 7.5 < -10 > 0.2 |
[ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] |
|
|
|
|
|
|
|
| |
| |
OR (DCDC converter voltage sensor C AND DCDC converter current sensor C AND for a period of time) |
< 7.5 < -10 > 0.2 |
[V] [V] [A] [ms] |
|
|
|
|
|
|
|
| P33CF - DC/DC converter LV output voltage excessive voltage |
Over voltage on LV side |
(DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 1 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR |
> 16.5 and ≤ 17.0 > 10 > 500 > 17.3 and ≤ 17.8 > 10 > 500 > 17 and ≤ 18 > 10 > 200 |
[V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
Depends on "Malfunction Criteria" |
[-] |
2 DCY |
| |
(DCDC converter voltage sensor 1 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 1 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 2 AND DCDC converter current sensor "C" AND for a period of time) OR (DCDC converter voltage sensor 1 |
> 17.8 and ≤ 18.8 > 10 > 200 > 18 and ≤ 19.5 > 10 > 50 > 18.8 and ≤ 20.3 > 10 > 50 > 19.5 > 10 > 0.2 > 20.3 |
[V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] [A] [ms] [V] [V] |
|
|
|
|
|
|
|
| |
| |
AND DCDC converter current sensor "C" AND for a period of time) |
> 10 > 0.2 |
[A] [ms] |
|
|
|
|
|
|
|
| P0E57 - DC/DC Converter Input Voltage Too High |
HV side Input voltage too high |
HV voltage |
> 490 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
105 |
[ms] |
2 DCY |
| P0A94 - DC/DC Converter "A" Performance |
Voltage high on clamp capacitor |
Clamp capacitor voltage |
≥ 95 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
280 |
[ms] |
2 DCY |
| P0A08 - DC/DC Converter Status Circuit |
Under voltage |
DSP Power supply voltage filtered value |
< 3.1 |
[V] |
DC/DC Converter monitoring |
= passed |
[-] |
Continuous |
20 |
[ms] |
2 DCY |
| P33CE - DC/DC converter LV voltage implausible |
LV battery plus open |
CASE 1: LV battery voltage - LV voltage value AND LV battery voltage - 2x (DC/DC converter voltage sensor 3) CASE 2: | LV voltage value - LV battery voltage | AND | 2x (DC/DC converter voltage sensor 3) - LV battery voltage | |
> 3.0 > 3.0 > 3.0 > 3.0 |
[V] [V] [V] [V] |
CASE 1: DCDC Current state CASE 2: DCDC Current state LV Battery plus diagnosis |
= Standby OR = HvOn OR = Error = Buck = not completed |
[-] [-] [-] |
Continuous |
400 |
[ms] |
2 DCY |
| P0D33 - DC/DC Converter Current High |
Current high on HV side |
DC/DC converter current sensor "A" |
> 25 |
[A] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
120, 2 |
[ms] |
2 DCY |
| P0E56 - DC/DC Converter Input Voltage Too Low |
Under voltage on HV side |
DC/DC converter voltage sensor "A" |
< 200 |
[V] |
Desired DCDC Current state Bus signal received state monitoring |
= Buck = passed |
[-] [-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| P0A08 - DC/DC Converter Status Circuit |
Voltage sensor 1 short to battery |
| DC/DC converter voltage sensor 1 - DC/DC converter voltage sensor "C" | AND DC/DC converter voltage sensor "C" |
≤ 1.12 > 5.2 |
[V] [V] |
DCDC Current state |
= HvOn OR = Buck OR = Error |
[-] |
Continuous |
160 |
[ms] |
2 DCY |
| Voltage sensor 3 short to ground |
DC/DC converter voltage sensor 3 AND DC/DC converter voltage sensor 1 |
≤ 0.1 > 2.3 |
[V] [V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
150 |
[ms] |
2 DCY |
| Voltage sensor 3 short to battery |
| DC/DC converter voltage sensor 3 - DC/DC converter voltage sensor 1 | AND DC/DC converter voltage sensor 1 |
≤ 1.74 > 5.2 |
[V] [V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
160 |
[ms] |
2 DCY |
| DC/DC converter current sensor "A" |
P0E54 - DC/DC Converter Current Sensor "A" Circuit High |
Circuit high |
DC/DC Converter Current Sensor "A" AD voltage |
≥ 3.2 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0E53 - DC/DC Converter Current Sensor "A" Circuit Low |
Circuit low |
DC/DC Converter Current Sensor "A" AD voltage |
≤ 0.1 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0E52 - DC/DC Converter Current Sensor "A" Circuit Range/Performance |
DCDC HV current out of range low |
HV current before filtering |
< - 10 |
[A] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| DC/DC converter current sensor "B" |
P0E9E - DC/DC Converter Current Sensor "B" Circuit High |
Circuit high |
DC/DC converter current sensor "B" AD voltage |
≥ 2.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
50 |
[ms] |
2 DCY |
| P0E9D - DC/DC Converter Current Sensor "B" Circuit Low |
Circuit low |
DC/DC converter current sensor "B" AD voltage |
≤ 0.1 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
50 |
[ms] |
2 DCY |
| P0E9C - DC/DC Converter Current Sensor "B" Circuit Range/Performance |
Plausibility fault |
| Calculation 1 - constant 1 | (see technical description) |
> calculation 2 |
[A] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
150 |
[ms] |
2 DCY |
| P0E9E - DC/DC Converter Current Sensor "B" Circuit High |
Out of range high |
DC/DC Converter Current Sensor "B" |
> 20 |
[A] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
100 |
[ms] |
2 DCY |
| P0E9D - DC/DC Converter Current Sensor "B" Circuit Low |
Out of range low |
DC/DC Converter Current Sensor "B" |
< - 20 |
[A] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
100 |
[ms] |
2 DCY |
| DC/DC converter current sensor "C" |
P0EA3 - DC/DC Converter Current Sensor "C" Circuit High |
Circuit high |
DC/DC Converter Current Sensor "C" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0EA2 - DC/DC Converter Current Sensor "C" Circuit Low |
Circuit low |
DC/DC Converter Current Sensor "C" A/D voltage value |
≤ 0.1 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0EA1 - DC/DC Converter Current Sensor "C" Circuit Range/Performance |
Plausibility fault |
| DC/DC Converter Current Sensor "C" - LV estimated current | |
> 75 |
[A] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
110 |
[ms] |
2 DCY |
| DC/DC converter temperature sensor "A" |
P0C3B - DC/DC Converter Temperature Sensor "A" High |
Circuit high |
DC/DC Converter Temperature Sensor "A" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0C3A - DC/DC Converter Temperature Sensor "A" Low |
Circuit low |
DC/DC Converter Temperature Sensor "A" A/D voltage value |
≤ 0.10 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| DC/DC converter temperature sensor "B" |
P0C3D - DC/DC Converter Temperature Sensor "B" Circuit |
Plausibility fault |
| Transformator temperature - Estimated transformator temperature | |
≥ 35 |
[°C] |
DCDC Current state Elapse time after switching ignition from off to on |
= Standby OR = HvOn OR = Buck OR = Error > 1000 |
[-] [ms] |
Continuous |
120 |
[ms] |
2 DCY |
| Estimated transformer temperature out of range |
Transformer estimated temperature OR |
≥ 150 |
[°C] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
110 |
[ms] |
2 DCY |
| |
Transformer estimated temperature |
≤ - 40 |
[°C] |
|
|
|
|
|
|
|
| P0C40 - DC/DC Converter Temperature Sensor "B" High |
Circuit high |
DC/DC Converter Temperature Sensor "B" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0C3F - DC/DC Converter Temperature Sensor "B" Low |
Circuit low |
DC/DC Converter Temperature Sensor "B" A/D voltage value |
≤ 0.10 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| DC/DC converter temperature sensor "C" |
P0E5B - DC/DC Converter Temperature Sensor "C" Circuit High |
Circuit high |
DC/DC Converter Temperature Sensor "C" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0E5A - DC/DC Converter Temperature Sensor "C" Circuit Low |
Circuit low |
DC/DC Converter Temperature Sensor "C" A/D voltage value |
≤ 0.10 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| DC/DC converter temperature sensor "D" |
P2C8F - DC/DC Converter Temperature Sensor "D" Circuit High |
Circuit high |
DC/DC Converter Temperature Sensor "D" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P2C8E - DC/DC Converter Temperature Sensor "D" Circuit Low |
Circuit low |
DC/DC Converter Temperature Sensor "D" A/D voltage value |
≤ 0.10 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| DC/DC converter temperature sensors |
P0C39 - DC/DC Converter Temperature Sensor "A" Range/Performance |
Temperature plausibility fault (crosscheck), sensors comparison |
(Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 |
[°C] [°C] [°C] [°C] [°C] |
Ignition Previous microprocessor shutdown Elapsed time after ignition on |
= on = successfully > 68 |
[-] [-] [min] |
Continuous |
40 |
[ms] |
2 DCY |
| |
Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 |
[°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] |
|
|
|
|
|
|
|
| P0C3E - DC/DC Converter Temperature Sensor "B" Range/Performance |
Temperature plausibility fault (crosscheck), sensors comparison |
(Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 |
[°C] [°C] [°C] [°C] |
Ignition Previous microprocessor shutdown Elapsed time after ignition on |
= on = successfully > 68 |
[-] [-] [min] |
Continuous |
40 |
[ms] |
2 DCY |
| |
Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 |
[°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] |
|
|
|
|
|
|
|
| P0E59 - DC/DC Converter Temperature Sensor "C" Circuit Range/Performance |
Temperature plausibility fault (crosscheck), sensors comparison |
(Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR |
> 50.. 20 > 50.. 20 > 50.. 20 |
[°C] [°C] [°C] |
Ignition Previous microprocessor shutdown Elapsed time after ignition on |
= on = successfully > 68 |
[-] [-] [min] |
Continuous |
40 |
[ms] |
2 DCY |
| |
Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 |
[°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] |
|
|
|
|
|
|
|
| P2C8D - DC/DC Converter Temperature Sensor "D" Circuit Range/Performance |
Temperature plausibility fault (crosscheck), sensors comparison |
(Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR |
> 50.. 20 > 50.. 20 |
[°C] [°C] |
Ignition Previous microprocessor shutdown Elapsed time after ignition on |
= on = successfully > 68 |
[-] [-] [min] |
Continuous |
40 |
[ms] |
2 DCY |
| |
Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up AND Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 14 > 14 > 14 |
[°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] |
|
|
|
|
|
|
|
| |
| DC/DC converter voltage sensor "A" |
P0E34 - DC/DC Converter Voltage Sensor "A" High |
Circuit high |
DC/DC Converter Voltage Sensor "A" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0E33 - DC/DC Converter Voltage Sensor "A" Low |
Circuit low |
DC/DC Converter Voltage Sensor "A" A/D voltage value AND Drive motor inverter voltage sensor "A" measured value |
≤ 0.1 > 32.7 |
[V] [V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0E32 - DC/DC Converter Voltage Sensor "A" Range/Performance |
Plausibility fault |
| Estimated DC/DC Converter voltage Sensor "A" voltage value - DC/DC Converter voltage Sensor "A" voltage value | |
> 43.63 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
100 |
[ms] |
1 DCY |
| DC/DC converter voltage sensor "B" |
P0E39 - DC/DC Converter Voltage Sensor "B" High |
Circuit high |
DSP clamp capacitor voltage |
≥ 2.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
150 |
[ms] |
2 DCY |
| P0E38 - DC/DC Converter Voltage Sensor "B" Low |
Circuit low |
DC/DC Converter Voltage Sensor "B" A/D voltage AND DC/DC Converter Voltage Sensor "C" |
≤ 0.1 > 5.6 |
[V] [V] |
DCDC Current state time elapse after safety switch is turned from OFF to ON |
= HvOn OR = Buck OR = Error > 50 |
[-] [ms] |
Continuous |
150 |
[ms] |
2 DCY |
| P0E37 - DC/DC Converter Voltage Sensor "B" Range/Performance |
Plausibility fault |
CASE 1: For H1 PWM duty average value (| DC/DC converter voltage sensor "B" - DC/DC converter voltage sensor "C" | AND | DC/DC converter voltage sensor "B" - 2x (DC/DC converter voltage sensor 1) |) CASE 2: For H1 PWM duty average value OR |
= 0 > 1.5 > 3.72 != 0 |
[-] [V] [V] [-] |
DCDC Current state Elapsed time after DC/DC PWM was stopped DC/DC converter voltage sensor "A" circuit low monitoring |
= Standby OR = HvOn OR > 60 = passed |
[-] [ms] [-] |
Continuous |
200 |
[ms] |
2 DCY |
| |
(| DC/DC converter voltage sensor "B" - HV voltage | AND | DC/DC converter voltage sensor "B" - HV redundant voltage |) |
> 23.32 > 36.54 |
[V] [V] |
|
|
|
|
|
|
|
| DC/DC converter voltage sensor "C" |
P0E99 - DC/DC Converter Voltage Sensor "C" Circuit High |
Circuit high |
DC/DC Converter Voltage Sensor "C" A/D voltage |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0E98 - DC/DC Converter Voltage Sensor "C" Circuit Low |
Circuit low |
DC/DC Converter Voltage Sensor "C" A/D voltage AND DC/DC converter voltage sensor 1 |
≤ 0.1 ≥ 1.0 |
[V] [V] |
DCDC Current state Voltage sensor 1 short to battery monitoring |
= HvOn OR = Buck OR = Error = Passed |
[-] [-] |
Continuous |
80 |
[ms] |
2 DCY |
| P0E97 - DC/DC Converter Voltage Sensor "C" Circuit Range/Performance |
Plausibility fault |
Case 1: For safety switches AND DCDC switch | DC/DC converter voltage sensor "C" - 2x (DC/DC converter voltage sensor 1) | | DC/DC converter voltage sensor "C" - DC/DC converter voltage sensor 3 | Case 2: For safety switches OR DCDC switch (DC/DC converter voltage sensor "C" AND DC/DC converter voltage sensor 1) OR DC/DC converter voltage sensor "C" |
= on > 1.84 > 2.1 = off > 1.62 ≤ 0.4 > 21.74 |
[-] [V] [V] [-] [V] [V] [V] |
DCDC Current state Elapse time after PWM duty has changed Voltage sensor 1 short to battery monitoring |
= Standby OR = HvOn OR = Buck OR = Error > 50 = Passed |
[-] [ms] [-] |
Continuous |
110 |
[ms] |
2 DCY |
| DC/DC converter voltage sensor 1 |
P32A5 - DC/DC converter voltage sensor 1 Short circuit to B+ |
Short to battery |
DC/DC converter voltage sensor 1 A/D voltage |
≥ 3.2 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P32A6 - DC/DC converter voltage sensor 1 Short circuit to Ground (GND) |
Short to ground |
DC/DC converter voltage sensor 1 AD voltage |
≤ 0.1 |
[V] |
DCDC Current state |
= HvOn OR = Buck OR = Error |
[-] |
Continuous |
100 |
[ms] |
2 DCY |
| |
AND DC/DC converter voltage sensor "C" AD voltage |
> 2.74 |
[V] |
|
|
|
|
|
|
|
| P32A7 - DC/DC converter voltage sensor 1 Range/Performance |
Out of range high |
DC/DC converter voltage sensor 1 voltage |
> 15 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| DC/DC converter voltage sensor 2 |
P32AA - DC/DC converter voltage sensor 2 Short circuit to B+ |
Short to battery |
DC/DC converter voltage sensor 2 AD voltage |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P32AB - DC/DC converter voltage sensor 2 Short circuit to Ground (GND) |
Short to ground |
DC/DC converter voltage sensor 2 AD voltage AND DC/DC converter voltage sensor 3 |
≤ 0.1 > 1.0 |
[V] [V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P32AC - DC/DC converter voltage sensor 2 Range/Performance |
Plausibility fault |
CASE 1: | DC/DC converter voltage sensor 2 - 2x (DC/DC converter voltage sensor 3) | AND | DC/DC converter voltage sensor 2 - DC/DC converter voltage sensor "C" | CASE 2: | DC/DC converter voltage sensor 2 - 2x (DC/DC converter voltage sensor 3) | AND | DC/DC converter voltage sensor 2 - Terminal 30 voltage | |
> 3.18 > 2.26 > 3.18 > 1.76 |
[V] [V] [V] [V] |
DCDC Current state Only for CASE 1: safety switches AND DCDC Switching Only for CASE 2: safety switches OR DCDC Switching |
= Standby OR = HvOn OR = Buck OR = Error = on = on = off = off |
[-] [-] [-] [-] [-] |
Continuous |
100 |
[ms] |
2 DCY |
| DC/DC converter voltage sensor 3 |
P32AF - DC/DC converter voltage sensor 3 Short circuit to B+ |
Short to battery |
DC/DC converter voltage sensor 3 AD value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P32B1 - DC/DC converter voltage sensor 3 Range/Performance |
Out of range high |
DC/DC converter voltage sensor 3 |
> 16.6 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| Drive motor |
P0C01 - Drive Motor "A" Current High |
Current high |
| AC current | |
≥ 900 |
[A] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
60 |
[ms] |
2 DCY |
| P0A2F - Drive Motor "A" Over Temperature |
Stator over temperature |
Drive motor stator temperature |
≥ 205 |
[°C] |
Drive mode Range switch of drive motor temperature sensor |
!= Standby Restart processing OR != Init. OR != Standby post run = initialized |
[-] [-] [-] [-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| |
| P0C4E - Drive Motor "A" Position Exceeded Learning Limit |
Drive motor position exceeded learning limit |
Angle offset Counter for angle offset out of range |
= out of range > 3 |
[-] [-] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
5 |
[ms] |
2 DCY |
| P0A90 - Drive Motor "A" Performance |
Performance fault |
Drive motor efficiency monitoring |
= failed |
[-] |
Drive mode Drive motor speed Drive motor torque |
= Normal torque control > 500 < 7000 > 75 < 500 |
- [-] [rpm] [Nm] |
Continuous |
180.000 |
[ms] |
2 DCY |
| P0A2F - Drive Motor "A" Over Temperature |
Rotor over temperature |
Rotor temperature |
> 155 |
[°C] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
10.000 |
[ms] |
2 DCY |
| Drive motor control module |
P0A1B - Drive Motor "A" Control Module Performance |
Vaux 5 V out of range |
Vaux 5 V OR Vaux 5 V |
< 4.63 +/-0.125 > 5.38 +/-0.125 |
[V] [V] |
None |
None |
[-] |
Continuous |
0.234 |
[ms] |
1 DCY |
| Vcore 3.3 V out of range |
Vaux 3.3 V OR Vaux 3.3 V |
< 2.82 +/-0.20 > 3.74 +/-0.14 |
[V] [V] |
None |
None |
[-] |
Continuous |
0.234 |
[ms] |
1 DCY |
| Power supply for ADC and drive motor inverter temperature sensor "B" out of range |
Vcc 5 V OR Vcc 5 V |
< 4.63 +/-0.125 > 5.38 +/-0.125 |
[V] [V] |
None |
None |
[-] |
Continuous |
0.234 |
[ms] |
1 DCY |
| FlexRay driver under voltage |
FlexRay driver power supply |
< 4.54 |
[V] |
None |
None |
[-] |
Continuous |
10 |
[ms] |
1 DCY |
| FlexRay driver over voltage |
FlexRay driver power supply |
> 5.49 |
[V] |
None |
None |
[-] |
Continuous |
10 |
[ms] |
1 DCY |
| Rotor position sensor under voltage |
Rotor position sensor power supply |
< 4.74 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Rotor position sensor over voltage |
Rotor position sensor power supply |
> 5.25 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Power supply of 6.5V out of range |
Power supply of 6.5 V |
> 7.6 +/- 0.4 |
[V] |
None |
None |
[-] |
Continuous |
0.234 |
[ms] |
1 DCY |
| CAN driver power supply under voltage |
CAN driver power supply |
< 4.50 |
[V] |
None |
None |
[-] |
Continuous |
50 |
[ms] |
1 DCY |
| CAN driver power supply over voltage |
CAN driver power supply |
> 5.53 |
[V] |
None |
None |
[-] |
Continuous |
50 |
[ms] |
1 DCY |
| Gate driver low side under voltage |
Gate driver low side voltage |
< 4.54 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Gate driver low side over voltage |
Gate driver low side voltage |
> 5.49 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| CPLD under voltage |
CPLD power supply |
< 3.18 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| CPLD over voltage |
CPLD power supply |
> 3.42 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Gate driver high side under voltage |
Gate drive high side voltage |
< 4.54 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Gate driver high side over voltage |
Gate drive high side voltage |
> 5.49 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Reference power supply over voltage |
Reference power supply |
> 3.04 |
[V] |
None |
None |
[-] |
Continuous |
20 |
[ms] |
1 DCY |
| Reference power supply under voltage |
Reference power supply |
< 2.96 |
[V] |
None |
None |
[-] |
Continuous |
20 |
[ms] |
1 DCY |
| Backup 7 V power supply under voltage |
Backup 7 V power supply |
< 4.87 |
[V] |
None |
None |
[-] |
Continuous |
10 |
[ms] |
1 DCY |
| Backup 7 V power supply over voltage |
Backup 7 V power supply |
> 7.90 |
[V] |
None |
None |
[-] |
Continuous |
10 |
[ms] |
1 DCY |
| ECU error: Shutoff paths test |
Shutoff path test |
= finished AND = failed |
[-] |
Pre-charge Ignition Shut off path test Monitor test |
= finished = on = finished = not completed |
[-] [-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| Drive motor current sensor |
P0A54 - Drive Motor "A" Current Sensor Circuit High |
High range high fault |
Drive motor current sensor AD voltage |
> 4.90 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| P0A53 - Drive Motor "A" Current Sensor Circuit Low |
High range low fault |
Drive motor current sensor AD voltage |
< 0.10 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| P0A52 - Drive Motor "A" Current Sensor Circuit Range/Performance |
Plausibility fault |
| HV DC current - Calculated HV DC current | |
> 68 |
[A] |
CPLD switching mode Ignition Drive motor speed HV voltage |
= PWM = on > 550 > 160 |
[-] [-] [rpm] [V] |
Continuous |
35 |
[ms] |
1 DCY |
| High range offset fault |
| DC/DC converter current sensor "A" - HV calculated current | for a period of time |
> 10 > 80 |
[A] [ms] |
Ignition DC current offset calculation Monitor test (CPLD switching mode AND (| Drive motor speed | for a period of time)) HV voltage calculation time out |
= on = done = not completed = Free wheel OR = Active short circuit ≤ 10 > 10 >8.75 = false |
[-] [-] [-] [-] [rpm] [ms] [V] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| Low range offset fault |
| DC/DC converter current sensor "C" - HV calculated current | for a period of time |
> 5 > 80 |
[A] [ms] |
Ignition DC current offset calculation Monitor test (CPLD switching mode AND (| Drive motor speed | for a period of time)) HV voltage |
= on = done = not completed = Free wheel OR = Active short circuit ≤ 10 > 10 >8.75 |
[-] [-] [-] [-] [rpm] [ms] [V] |
Continuous |
5 |
[ms] |
1 DCY |
| |
|
|
|
calculation time out |
= false |
[-] |
|
|
|
|
| P0A54 - Drive Motor "A" Current Sensor Circuit High |
Low range high fault |
Drive motor current sensor AD voltage |
> 4.90 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| P0A53 - Drive Motor "A" Current Sensor Circuit Low |
Low range low fault |
Drive motor current sensor AD voltage |
< 0.10 |
[V] |
None |
None |
[-] |
Continuous |
15 |
[ms] |
1 DCY |
| Out of range high |
Drive motor current sensor current |
> 600 |
[A] |
None |
None |
[-] |
Continuous |
25 |
[ms] |
1 DCY |
| P0A54 - Drive Motor "A" Current Sensor Circuit High |
Out of range low |
Drive motor current sensor current |
< -600 |
[A] |
Ignition |
None |
[-] |
Continuous |
25 |
[ms] |
1 DCY |
| Drive motor inverter |
P0A3C - Drive Motor "A" Inverter Over Temperature |
Over temperature |
Drive motor inverter calculated temperature OR Intermediate coolant temperature model calculated value OR IGBT temperature |
≥ 165 ≥ 100 ≥ 156 |
[°C] [°C] [°C] |
Drive mode (HV voltage OR AC current) |
!= Standby Restart processing OR != Init. OR != Standby post run ≥ 100 ≥ 50 |
[-] [-] [-] [V] [A] |
Continuous |
100 |
[ms] |
2 DCY |
| P0C79 - Drive Motor "A" Inverter Voltage Too High |
Voltage high |
Inverter voltage |
> 475 ± 10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
45 |
[ms] |
2 DCY |
| P0A3C - Drive Motor "A" Inverter Over Temperature |
X-Capacitor over temperature |
X-Capacitor temperature |
≥ 110 |
[°C] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| AC connector over temperature |
AC connector temperature |
≥ 180 |
[°C] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| Power module AC terminal over temperature |
Power module AC terminal temperature |
≥ 180 |
[°C] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| Y- Capacitor over temperature |
Y-Capacitor temperature |
≥ 110 |
[°C] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| Over temperature on PCB |
PCB temperature |
≥ 140 |
[°C] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
200 |
[ms] |
2 DCY |
| Drive motor inverter temperature sensor "A" |
P0AEE - Drive Motor Inverter Temperature Sensor "A" Circuit Range/Performance |
Plausibility fault |
| Drive Motor Inverter Temperature Sensor "A" - DC/DC converter temperature sensor "D" | |
> 50.. 20 |
[°C] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
200 |
[ms] |
1 DCY |
| |
OR | Drive motor inverter temperature Sensor "A" - Drive motor inverter temperature sensor "B" | |
> 50.. 20 |
[°C] |
Ignition Rest period Previous microprocessor shutdown |
on > 100 = successfully |
[-] [min] [-] |
|
|
|
|
| P0AF0 - Drive Motor Inverter Temperature Sensor "A" Circuit High |
Short to battery |
Duty cycle temperature sensor |
≥ 89.5 |
[%] |
Drive mode HV voltage |
!= Standby Restart processing OR != Init. OR != Standby post run ≥ 60 |
[-] [-] [-] [V] |
Continuous |
50 |
[ms] |
1 DCY |
| P0AEF - Drive Motor Inverter Temperature Sensor "A" Circuit Low |
Short to ground |
Duty cycle temperature sensor |
≤ 10.5 |
[%] |
Drive mode HV voltage |
!= Standby Restart processing OR != Init. OR != Standby post run ≥ 60 |
[-] [-] [-] [V] |
Continuous |
50 |
[ms] |
1 DCY |
| Circuit low |
Inverter temperature |
≤ -52 |
[°C] |
Drive mode HV voltage |
!= Standby Restart processing OR != Init. OR != Standby post run ≥ 60 |
[-] [-] [-] [V] |
Continuous |
100 |
[ms] |
1 DCY |
| Drive motor inverter temperature sensor "B" |
P0AF5 - Drive Motor Inverter Temperature Sensor "B" Circuit High |
Circuit high |
Drive Motor Inverter Temperature Sensor "B" A/D voltage value |
≥ 4.9 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0AF4 - Drive Motor Inverter Temperature Sensor "B" Circuit Low |
Circuit low |
Drive Motor Inverter Temperature Sensor "B" A/D voltage value |
≤ 0.10 |
[V] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
30 |
[ms] |
2 DCY |
| P0AF3 - Drive Motor Inverter Temperature Sensor "B" Circuit Range/Performance |
Temperature plausibility fault (crosscheck), sensors comparison |
(Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 |
[°C] [°C] [°C] [°C] |
Ignition Previous microprocessor shutdown Rest period |
= on = successfully > 68 |
[-] [-] [min] |
Continuous |
40 |
[ms] |
2 DCY |
| |
Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "A" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "C" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up OR Absolute difference between DC/DC converter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up) AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "A" temperature stored value at start up AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "C" temperature stored value at start up AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "B" temperature stored value at start up AND Absolute difference between drive motor inverter temperature sensor "B" temperature stored value at start up and DC/DC converter temperature sensor "D" temperature stored value at start up |
> 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 50.. 20 > 16.2 > 16.2 > 16.2 > 16.2 |
[°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] [°C] |
|
|
|
|
|
|
|
| Drive motor inverter voltage sensor "A" |
P0D30 - Drive Motor "A" Inverter Voltage Sensor "A" Circuit High |
Short to battery |
Drive motor inverter voltage sensor "A" AD voltage AND HV redundant AD voltage |
≥ 4.90 < 4.14 |
[V] [V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
25 |
[ms] |
1 DCY |
| P0D2E - Drive Motor "A" Inverter Voltage Sensor "A" Circuit Range/Performance |
Plausibility fault |
| Drive motor Inverter Voltage Sensor "A" voltage physical value - Drive motor Inverter Voltage Sensor "A" redundant voltage value | |
> 43.63 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
40 |
[ms] |
1 DCY |
| |
Drive motor Inverter Voltage Sensor "A" redundant raw value Drive motor Inverter Voltage Sensor "A" redundant raw value |
< 4.8 > 0.1 |
[V] [V] |
|
|
|
|
|
|
|
| P0D30 - Drive Motor "A" Inverter Voltage Sensor "A" Circuit High |
Out of range high |
Drive motor inverter voltage sensor "A" voltage physical value |
≥ 630 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
30 |
[ms] |
1 DCY |
| P0D2D - Drive Motor "A" Inverter Voltage Sensor "A" Circuit |
HV DC offset under voltage |
HV DC offset voltage |
< 2.00 |
[V] |
None |
None |
[-] |
Continuous |
20 |
[ms] |
1 DCY |
| HV DC offset over voltage |
HV DC offset voltage |
> 2.71 |
[V] |
None |
None |
[-] |
Continuous |
20 |
[ms] |
1 DCY |
| Drive motor phase U |
P0A5D - Drive Motor "A" Phase U Current |
Open circuit before operation |
U phase current U phase open circuit before operation error counter |
< 5.49 > 7 |
[A] [-] |
Ignition V phase open circuit before operation W phase open circuit before operation Ripoff monitoring Monitor test |
= on = passed = passed = competed = not completed |
[-] [-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| Drive motor phase U current sensor |
P0BE6 - Drive Motor "A" Phase U Current Sensor Circuit Range/Performance |
Offset fault |
| sensor offset phase U | AND for a period of time |
> 20.86 > 35 |
[A] [ms] |
Ignition AC current offset calculation Ripoff monitoring Monitor test (CPLD switching mode AND (| Drive motor speed | for a period of time)) |
= on = done = not done yet = not completed = Free wheel OR = Active short circuit ≤ 10 > 10 |
[-] [-] [-] [-] [-] [rpm] [ms] |
once / DCY |
n/a |
[ms] |
1 DCY |
| Drive motor phase U-V W |
P0C05 - Drive Motor "A" Phase U-V-W Circuit/Open |
2 or 3 phases open circuit before operation |
U phase open circuit before operation AND V phase open circuit before operation OR |
= failed = failed |
[-] [-] |
Ignition Ripoff monitoring |
= on = competed |
[-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| |
U phase open circuit before operation AND W phase open circuit before operation OR V phase open circuit before operation AND W phase open circuit before operation OR U phase open circuit before operation AND V phase open circuit before operation AND W phase open circuit before operation AND Phases open circuit before operation error counter |
= failed = failed = failed = failed = failed = failed = failed |
[-] [-] [-] [-] [-] [-] [-] |
Monitor test |
= not completed |
[-] |
|
|
|
|
| Drive motor phase U-V W current sensor |
P0BE8 - Drive Motor "A" Phase U Current Sensor Circuit High |
Short to battery |
U Phase current AD voltage |
≥ 4.90 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| P0BE7 - Drive Motor "A" Phase U Current Sensor Circuit Low |
Short to ground |
U Phase current AD voltage |
≤ 0.10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| P0BFD - Drive Motor "A" Phase U-V-W Current Sensor Correlation |
Crosscheck drive motor phase current balance U, V, W sensors |
AC Current 3 phases sum |
≥ 66.98 |
[A] |
Drive mode Ignition |
!= Standby Restart processing OR != Init. OR != Standby post run = on |
[-] [-] [-] [-] |
Continuous |
25 |
[ms] |
1 DCY |
| P0BEC - Drive Motor "A" Phase V Current Sensor Circuit High |
Short to battery |
V Phase current AD voltage |
≥ 4.90 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| P0BEB - Drive Motor "A" Phase V Current Sensor Circuit Low |
Short to ground |
V Phase current AD voltage |
≤ 0.10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| P0BF0 - Drive Motor "A" Phase W Current Sensor Circuit High |
Short to battery |
W Phase current AD voltage |
≥ 4.90 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| P0BEF - Drive Motor "A" Phase W Current Sensor Circuit Low |
Short to ground |
W Phase current AD voltage |
≤ 0.10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
20 |
[ms] |
1 DCY |
| Drive motor phase V |
P0A60 - Drive Motor "A" Phase V Current |
Open circuit before operation |
V phase current V phase open circuit before operation error counter |
< 5.49 > 7 |
[-] [-] |
Ignition U phase open circuit before operation W phase open circuit before operation |
= on = passed = passed |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| |
|
|
|
Ripoff monitoring Monitor test |
= competed = not completed |
[-] [-] |
|
|
|
|
| Drive motor phase V current sensor |
P0BEA - Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
Drive motor phase V current offset fault |
| sensor offset phase V | AND time |
> 20.86 > 35 |
[A] [ms] |
Ignition AC current offset calculation Monitor test Ripoff monitoring (CPLD switching mode AND (| Drive motor speed | for a period of time)) |
= on = done = not completed = not done yet = Free wheel OR = Active short circuit ≤ 10 > 10 |
[-] [-] [-] [-] [-] [rpm] [ms] |
once / DCY |
n/a |
[ms] |
1 DCY |
| Drive motor phase W |
P0A63 - Drive Motor "A" Phase W Current |
Open circuit before operation |
W phase current W phase open circuit before operation error counter |
< 5.49 > 7 |
[-] [-] |
Ignition U phase open circuit before operation V phase open circuit before operation Ripoff monitoring Monitor test |
= on = passed = passed = competed = not completed |
[-] [-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| Drive motor phase W current sensor |
P0BEE - Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
Drive motor phase W current offset fault |
| sensor offset phase W | AND for a period of time |
> 20.86 > 35 |
[A] [ms] |
Ignition AC current offset calculation Monitor test Ripoff monitoring (CPLD switching mode AND |
= on = done = not completed = not done yet = Free wheel OR = Active short circuit |
[-] [-] [-] [-] [-] |
once / DCY |
n/a |
[ms] |
1 DCY |
| |
|
|
|
(|Drive motor speed | for a period of time)) |
≤ 10 > 10 |
[rpm] [ms] |
|
|
|
|
| Drive motor position sensor |
P0A3F - Drive Motor "A" Position Sensor Circuit |
Sine and Cosine circuit high |
SIN and COS position sensor |
≥ 4.43 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
25 |
[ms] |
1 DCY |
| Sine and Cosine circuit low |
SIN and COS position sensor |
≤ 0.50 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
25 |
[ms] |
1 DCY |
| P0A40 - Drive Motor "A" Position Sensor Circuit Range/Performance |
Sine and Cosine ratio fault |
Amplitude difference between SIN and COS |
≥ 22.5 ≤ - 29 |
[%] |
Drive mode SIN / COS compensation monitoring This diagnosis |
!= Standby Restart processing OR != Init. OR != Standby post run = completed = has not been done |
[-] [-] [-] [-] [-] |
Continuous |
75 |
[ms] |
1 DCY |
| Rotor position sensor SIN / COS variation fault |
Sum of normalized SIN square and normalized COS square |
≥ 1.28 ≤ 0.71 |
[pu] [pu] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
50 |
[ms] |
1 DCY |
| Rotor position sensor loss of tracking fault |
Integrator tracking observer |
≥ 90 |
[°] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
50 |
[ms] |
1 DCY |
| Circuit Range/Performance |
| Drive motor speed - Calculated drive motor speed | OR (| Drive motor speed - Calculated drive motor speed | AND |Drive motor speed - Motor speed after cross fade processing|) |
≥ 32, 767 < 50 ≥ 150 |
[rpm] [rpm] [rpm] |
Ignition |
= on |
[-] |
Continuous |
80 |
[ms] |
1 DCY |
| P0A44 - Drive Motor "A" Position Sensor Circuit Overspeed |
Over speed fault |
Drive motor speed |
≤ -1, 210 ≥ 7, 410 |
[rpm] [rpm] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
80 |
[ms] |
2 DCY |
| P0C52 - Drive Motor "A" Position Sensor Circuit "A" Low |
Signal low |
SIN signal position sensor |
< 0.34 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
45 |
[ms] |
1 DCY |
| P0C53 - Drive Motor "A" Position Sensor Circuit "A" High |
Signal high |
SIN signal position sensor |
> 4.66 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
45 |
[ms] |
1 DCY |
| Short to battery |
SIN position sensor |
> 4.90 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
35 |
[ms] |
1 DCY |
| P0C52 - Drive Motor "A" Position Sensor Circuit "A" Low |
Short to ground |
SIN position sensor |
< 0.10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
35 |
[ms] |
1 DCY |
| P0C5C - Drive Motor "A" Position Sensor Circuit "B" Low |
Signal low |
COS position sensor |
< 0.34 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
45 |
[ms] |
1 DCY |
| P0C5D - Drive Motor "A" Position Sensor Circuit "B" High |
Signal high |
COS signal position sensor |
> 4.66 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
45 |
[ms] |
1 DCY |
| Short to battery |
COS signal position sensor |
> 4.90 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
35 |
[ms] |
1 DCY |
| P0C5C - Drive Motor "A" Position Sensor Circuit "B" Low |
Short to ground |
COS position sensor |
< 0.10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
35 |
[ms] |
1 DCY |
| Drive motor temperature sensor |
P0A2A - Drive Motor "A" Temperature Sensor "A" Circuit |
Diagnosis switch monitoring |
Range switch Diagnosis switch voltage absolute difference after switching |
= on < 0.5 |
[-] [V] |
Ignition Monitor test Range switch of drive motor temperature sensor |
= on = not completed = initialized |
[-] [-] [-] |
Continuous |
45 |
[ms] |
2 DCY |
| P0A2D - Drive Motor "A" Temperature Sensor "A" Circuit High |
Short to battery |
Voltage measure drive motor temperature sensor |
≥ 4.70 |
[V] |
Stator switching temperature Range switch of drive motor temperature sensor |
≤ 75 = initialized |
[°C] [-] |
Continuous |
15 |
[ms] |
2 DCY |
| P0A2C - Drive Motor "A" Temperature Sensor "A" Circuit Low |
Short to ground |
Voltage measure drive motor temperature sensor |
≤ 0.10 |
[V] |
Stator switching temperature Range switch of drive motor temperature sensor |
> 75 = initialized |
[°C] [-] |
Continuous |
15 |
[ms] |
2 DCY |
| P0A2E - Drive Motor "A" Temperature Sensor "A" Circuit Intermittent |
Circuit Intermittent |
| Drive motor temperature sensor - previous stored drive motor temperature | |
> 20 |
[°C] |
Range switch of drive motor temperature sensor |
= initialized |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| P0A2B - Drive Motor "A" Temperature Sensor "A" Circuit Range/Performance |
Temperature plausibility fault (crosscheck) |
| Drive motor Temperature Sensor - Transmission oil temperature | |
> 50.. 20 |
[°C] |
Drive mode Ignition |
!= Standby Restart processing OR != Init. OR != Standby post run on |
[-] [-] [-] [-] |
Continuous |
200 |
[ms] |
1 DCY |
| |
|
|
|
HV voltage off time Previous microprocessor shutdown Time after DMCM wakeup |
> 100 = successfully < 4 |
[min] [-] [min] |
|
|
|
|
| P0A2A - Drive Motor "A" Temperature Sensor "A" Circuit |
Range switch monitoring |
Diagnosis switch Range switch voltage absolute difference after switching |
= on < 0.6 |
[-] [V] |
Ignition Monitor test Range switch of drive motor temperature sensor |
= on = not completed = initialized |
[-] [-] [-] |
Continuous |
45 |
[ms] |
2 DCY |
| P0A2D - Drive Motor "A" Temperature Sensor "A" Circuit High |
Out of range low |
Motor temperature sensor |
≤ -43.88 |
[°C] |
Stator switching temperature Range switch of drive motor temperature sensor |
≤ 75 = initialized |
[°C] [-] |
Continuous |
30 |
[ms] |
2 DCY |
| FlexRay communicaiton |
U0112 - Lost Communication With Battery Energy Control Module "B" |
Lost Communication With Battery Energy Control Module "B" (time out) |
Message time out Data length |
= invalid |
[-] [-] |
Ignition on |
> 500 |
[ms] |
Continuous |
5.000 |
[ms] |
1 DCY |
| U0101 - Lost Communication with TCM |
Lost Communication with TCM (time out) |
Message time out Data length |
= invalid |
[-] [-] |
Ignition on |
> 500 |
[ms] |
Continuous |
800 |
[ms] |
2 DCY |
| U0146 - Lost Communication With Serial Data Gateway Module "A" |
Lost Communication With Gateway "A" (time out) |
Message time out Data length |
= invalid |
[-] [-] |
Ignition on |
> 500 |
[ms] |
Continuous |
5.000 |
[ms] |
2 DCY |
| U0141 - Lost Communication With Body Control Module "A" |
Lost Communication With Body Control Module "A" (time out) |
Message time out Data length |
= invalid |
[-] [-] |
Ignition on |
> 500 |
[ms] |
Continuous |
1.000 |
[ms] |
2 DCY |
| U0140 - Lost Communication With Body Control Module |
Lost Communication With Body Control Module (time out) |
Message time out Data length |
= invalid |
[-] [-] |
Ignition on |
> 500 |
[ms] |
Continuous |
2.000 |
[ms] |
2 DCY |
| U0100 - Lost Communication With ECM/PCM "A" |
Lost Communication With ECM/PCM "A" (time out) |
Message time out Data length |
= invalid |
[-] [-] |
Ignition on |
> 500 |
[ms] |
Continuous |
5.000 |
[ms] |
1 DCY |
| U0431 - Invalid Data Received From Body Control Module "A" |
Body control module "A" plausibility fault |
Information content |
= not plausible |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
1.000 |
[ms] |
2 DCY |
| U0401 - Invalid Data Received From ECM/PCM "A" |
Engine control module "A" plausibility fault |
Information content |
= not plausible |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
500 |
[ms] |
1 DCY |
| U0080 - Vehicle Communication Bus F |
Flex Ray synchronization lost |
FlexRay lost synchronization |
= transmitting and receiving no message |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
0 |
[ms] |
1 DCY |
| U106E - FlexRay data bus Signal malfunction |
Flex Ray transmission collision |
FlexRay message |
= no feedback |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
0 |
[ms] |
1 DCY |
| U0413 - Invalid Data Received From Battery Energy Control Module "B" |
Invalid data received from battery energy control module |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
3.000 |
[ms] |
1 DCY |
| U0402 - Invalid Data Received From TCM |
Invalid data received from transmission control module |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
240 |
[ms] |
2 DCY |
| U0447 - Invalid Data Received From Serial Data Gateway Module "A" |
Invalid data received from gateway |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
30 |
[ms] |
2 DCY |
| U0422 - Invalid Data Received From Body Control Module |
Invalid data received from body control module 1 |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
600 |
[ms] |
2 DCY |
| U0401 - Invalid Data Received From ECM/PCM "A" |
Invalid data received from engine control module "A" |
Information content |
= invalid |
[-] |
Ignition on |
> 500 |
[ms] |
Continuous |
2.880 |
[ms] |
1 DCY |
| Function restriction |
U1400 - Function restriction Function restriction due to low voltage |
due to insufficient voltage from power supply |
LV battery voltage |
> 5.75 < 8.75 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
100 |
[ms] |
2 DCY |
| U1401 - Function restriction due to excessive voltage |
due to excessive voltage from power supply |
LV battery voltage |
> 16.375 < 30 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
100 |
[ms] |
2 DCY |
| U141B - Function restriction due to special software |
due to special software |
Software manipulation |
= detected |
[-] |
None |
None |
[-] |
Continuous |
1.000 |
[ms] |
1 DCY |
| High voltage fuse |
P0A95 - High Voltage Fuse "A" |
Fuse fault |
Fuse open duty |
≥ 70 |
[%] |
Drive mode HV voltage |
!= Standby Restart processing OR != Init. OR != Standby post run ≥ 60 |
[-] [-] [-] [V] |
Continuous |
1.000 |
[ms] |
2 DCY |
| Hybrid/EV battery system |
P0AFA - Hybrid/EV Battery System Voltage Low |
Inverter under voltage |
Drive motor inverter voltage sensor "A" measured value |
≤ 130 |
[V] |
Desired drive mode Drive mode Desired drive mode signal received on FlexRay |
= moment regulation OR = External rpm regulation OR = calibration OR = special brake mode != Standby Restart processing OR != Init. OR != Standby post run = valid |
[-] [-] [-] [-] [-] [-] [-] [-] |
Continuous |
60 |
[ms] |
1 DCY |
| Ignition switch run/start position |
P2535 - Ignition Switch On/Start Position "A" Circuit High |
Terminal 15 voltage sensor short to battery |
Terminal 15 voltage AD voltage value |
> 4.90 |
[V] |
None |
None |
[-] |
Continuous |
50 |
[ms] |
1 DCY |
| Internal control module |
U1103 - Production mode active |
Production mode active |
Production mode |
= active |
[-] |
VW End of line session |
= permitted OR = requested |
[-] |
Continuous |
1.000 |
[ms] |
1 DCY |
| |
|
|
|
Development session Vehicle mileage |
=permitted OR = requested ≤ 100 |
[-] [km] |
|
|
|
|
| U0300 - Internal Control Module Software Incompatibility |
Software incompatibility |
Actual OBD type |
!= stored OBD type |
[-] |
Variant code |
= written |
[-] |
Instantly |
|
|
1 DCY |
| U3510 - Control Module Missing Calibration |
Missing calibration |
Variant code |
= not written OR = corrupted |
[-] |
Immobilizer |
= downloaded |
[-] |
Instantly |
|
|
1 DCY |
| U3001 - Control Module Improper Shutdown Performance |
Maximum number of resets achieved |
Number of continuous resets |
≥ 5 |
[-] |
Monitoring not executed since previous reset |
|
[-] |
Continuous |
1 |
[ms] |
1 DCY |
| Internal control module A/D |
P060B - Internal Control Module A/D Processing Performance |
AC current sensor U phase plausibility fault |
U phase current error counter |
> 100 |
[-] |
None |
None |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| AC current sensor V phase plausibility fault |
V phase current error counter |
> 100 |
[-] |
None |
None |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| AC current sensor W phase plausibility fault |
W phase current error counter |
> 100 |
[-] |
None |
None |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| Sine signal plausibility fault |
Position sensor SIN signal error counter |
> 100 |
[-] |
None |
None |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| Cosine signal plausibility fault |
Position sensor COS signal error counter |
> 100 |
[-] |
None |
None |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| Internal control module main processor |
P060C - Internal Control Module Main Processor Performance |
CPLD clock monitoring |
Counter for CPLD Clock out of range |
≥ 4 |
[-] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| ECU error: actual torque notch filter monitoring |
Actual torque notch filter monitoring |
= failed |
[-] |
Ignition |
= on |
[-] |
Continuous |
5 |
[ms] |
1 DCY |
| ECU error: data flashing check |
CRC error of data flash |
= detected |
[-] |
Monitor test |
= not completed |
[-] |
Instantly |
|
|
1 DCY |
| ECU error: Drive motor inverter voltage sensor plausibility fault |
| inverter side HV DC voltage - DCDC side HV DC voltage | AND HV voltage digital value |
> 43.625 < 0.10 > 4.90 |
[V] [V] [V] |
None |
None |
[-] |
Continuous |
35 |
[ms] |
1 DCY |
| ECU error: torque anti-jerk function monitoring fault |
Anti-jerk torque function monitoring |
= failed |
[-] |
Ignition |
= on |
[-] |
Continuous |
1 |
[ms] |
1 DCY |
| ECU error: ICE rotary oscillation damper torque function monitoring fault |
ICE rotary oscillation damper torque monitoring |
= failed |
[-] |
Ignition |
= on |
[-] |
Continuous |
1 |
[ms] |
1 DCY |
| ECU error: Torque monitoring fault, negative side |
Delivered torque |
= out of range |
[-] |
Torque monitoring Ripoff monitoring Ignition |
= passed = passed = on |
[-] [-] [-] |
Continuous |
120 |
[ms] |
1 DCY |
| ECU error: Torque monitoring fault, positive side |
Delivered torque for a period of time |
= out of range > 2, 175 |
[-] [ms] |
Torque monitoring Ripoff monitoring Ignition |
= passed = passed = on |
[-] [-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| ECU error: Torque Monitoring HW check fault, negative side over deviation |
Torque negative deviation monitoring |
= failed |
[-] |
Torque monitoring Ripoff monitoring Ignition |
= passed = passed = on |
[-] [-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| ECU error: Torque Monitoring HW check fault, negative side integration over deviation |
Torque negative integration deviation monitoring |
= failed |
[-] |
Torque monitoring Ripoff monitoring Ignition |
= passed = passed = on |
[-] [-] [-] |
Continuous |
30 |
[ms] |
1 DCY |
| ECU error: drive motor over speed |
Drive motor speed |
≤ -1, 260 ≥ 7, 460 |
[rpm] |
Ignition |
= on |
[-] |
Continuous |
75 |
[ms] |
1 DCY |
| ECU error: HV DC current during free wheel |
HV DC current error at free wheel |
≥ 60 |
[A] |
(CPLD switching mode OR Drive motor desired mode OR Quality management error OR Security error OR Ignition OR Vehicle crash |
= Free wheel OR = Active short circuit = passive mode = detected = detected = off = detected |
[-] [-] [-] [-] [-] [-] |
Continuous |
40 |
[ms] |
1 DCY |
| |
|
|
|
OR Terminal 30 voltage) AND This diagnosis AND DC offset calculation |
= under voltage = has not been delayed = finished |
[-] [-] [-] |
|
|
|
|
| ECU error: Actual torque plausibility fault |
| Actual torque - Delivered torque | AND Drive motor speed |
> 50 > 500 |
[Nm] [rpm] |
CPLD switching mode |
= PWM |
[-] |
Continuous |
130 |
[ms] |
1 DCY |
| ECU error: Torque Monitoring HW check fault, positive side integration over deviation |
Torque positive integration deviation monitoring |
= failed |
[-] |
Torque monitoring Ripoff monitoring Ignition |
= passed = passed = on |
[-] [-] [-] |
Continuous |
30 |
[ms] |
1 DCY |
| ECU error: Rotor position sensor Sine / Cosine value out of range |
Position sensor SIN signal OR Position sensor COS signal |
≤ 280.917 ≥ 3, 814.083 ≤ 280.917 ≥ 3, 814.083 |
[-] [-] |
Ignition |
= on |
[-] |
Continuous |
35 |
[ms] |
1 DCY |
| ECU error: Rotor position sensor sine / cosine variation fault |
Sum of SIN square and COS square |
≤ 1, 054 ≥ 1, 892 |
[-] |
Ignition |
= on |
[-] |
Continuous |
40 |
[ms] |
1 DCY |
| ECU error: AC current sensor fault |
Sum average of 3 phase AC currents OR Sum average of 3 phase AC currents |
< 2.45 > 2.55 |
[-] [-] |
Ignition |
= on |
[-] |
Continuous |
25 |
[ms] |
1 DCY |
| ECU error: internal error check |
Internal error check |
=failed |
[-] |
Monitor test Drive mode |
= not completed != Standby, Post run |
[-] [-] |
Continuous |
1.000 |
[ms] |
1 DCY |
| ECU error: AC current during passive mode |
| U phase current | OR | V phase current | OR | W phase current | |
> 149.88 OR > 149.88 OR > 149.88 |
[A] [A] [A] |
(CPLD switching mode OR Drive motor desired mode OR Ignition OR Desired PWM mode) AND This diagnosis |
= Free wheel OR = Active short circuit = passive mode = off = passive mode = has not been delayed |
[-] [-] [-] [-] [-] |
Continuous |
5 |
[ms] |
1 DCY |
| ECU error: torque monitoring fault, drive off in wrong direction |
AC current integral value |
≥ 40 |
[A] |
CPLD switching mode Ripoff monitoring Ignition Drive motor speed Delivered power AC current |
= PWM = passed = on ≥ - 1500 AND ≤ -150 > 600 > 30 |
[-] [-] [-] [rpm] [rpm] [W] [A] |
Continuous |
5 |
[ms] |
1 DCY |
| DSP state monitoring |
DSP control mode and microcontroller mode |
= mismatch |
[-] |
DCDC Current state Elapsed time after DCDC control mode has changed |
= Standby OR = HvOn OR = Buck OR = Error > 80 |
[-] [ms] |
Continuous |
80 |
[ms] |
2 DCY |
| DSP internal error |
DSP receiving message from serial peripheral interface |
= failed |
[-] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| DSP program run time out |
DSP sending program run signal after micro controller start up |
= failed |
[-] |
DCDC Current state |
= sleep |
[-] |
Continuous |
1.000 |
[ms] |
2 DCY |
| |
|
|
|
Serial peripheral interface data compatibility check Elapsed time after microcontroller startup |
= not finished > 40 |
[-] [ms] |
|
|
|
|
| Serial peripheral interface communication error |
Serial peripheral interface sending or receiving monitoring |
= failed |
[-] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| Sum of digital signal processing and serial peripheral interface |
Sum value on serial peripheral interface and calculated sum value |
= mismatch |
[-] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| Digital signal processing data |
Main processor requesting data and digital signal processing sending data |
= mismatch |
[-] |
DCDC Current state |
= Standby OR = HvOn OR = Buck OR = Error |
[-] |
Continuous |
40 |
[ms] |
2 DCY |
| System voltage |
P0562 - System Voltage Low |
Low voltage battery voltage low |
Terminal 30 voltage of DMCM |
≤ 5.75 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
9.000 |
[ms] |
2 DCY |
| P0563 - System Voltage High |
Low voltage battery voltage high |
Terminal 30 voltage of DMCM |
≥ 30 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] [-] [-] |
Continuous |
9.000 |
[ms] |
2 DCY |
| P0560 - System Voltage |
Terminal 30 rationality fault |
| Terminal 30 voltage of DMCM - DCDC converter voltage sensor 2 | |
> 4.8 |
[V] |
Drive mode Battery plus open monitoring status |
!= Standby Restart processing OR != Init. OR != Standby post run = completed |
[-] [-] [-] [-] |
Continuous |
320 |
[ms] |
1 DCY |
| P0563 - System Voltage High |
Low voltage battery voltage circuit high |
Terminal 30 voltage of DMCM AD voltage value |
> 4.90 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
40 |
[ms] |
1 DCY |
| P0562 - System Voltage Low |
Low voltage battery voltage circuit low |
Terminal 30 voltage of DMCM AD voltage value |
< 0.10 |
[V] |
Drive mode |
!= Standby Restart processing OR != Init. OR != Standby post run |
[-] |
Continuous |
40 |
[ms] |
1 DCY |
| U1405 - Terminal 15 Implausible signal |
Terminal 15 rationality check |
Terminal 15 and FlexRay Terminal 15 signal |
= unmatched |
[-] |
FlexRay signal ignition |
= received |
[-] |
Continuous |
2.000 |
[ms] |
1 DCY |