Special tools required:

NOTE: Electrical components which are particularly sensitive to electrostatic discharge (electronic control units, sensors, etc.) are marked with the ESD warning symbol.

E-  Electro

S-  Static

D-  Discharge

Statically charged persons can discharge by touching electrical components.

NOTE: Humans can only detect a discharge starting from a level of approx. 3000 V.

The danger threshold for electrical components already starts from a level of approx. 100 V.

Fig 1: Touching Electrical Component
G03125209Courtesy of BMW OF NORTH AMERICA, INC.
Fig 2: Identifying Correct Way Of Handling Electrical Component
G03125210Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Do not touch pins or multi-pin connectors directly!

Touch electrical components by their housings only.

IMPORTANT: To prevent electrical components from being damaged or destroyed by electrostatic discharge, it is absolutely essential to comply with the following instructions:
  • When replacing electrical components, leave the replacement components in their original packaging until immediately before they are to be installed
  • If necessary, always return a removed component in its original packaging (always pack the component away immediately)
  • Read and comply with user information on using the associated ESD special tool 12 7 060