Chassis Integrated Module (CIM) Fault Code D98F "Timeout DME Message" (32 200 05)
Publication date: 2005-06-01Reference number: 32 200 05
Supersedes refnos: 32 02 05
CHASSIS INTEGRATED MODULE (CIM) FAULT CODE D98F "TIMEOUT DME MESSAGE"
TECHNICAL SERVICE BULLETIN
Reference Number(s): SI B 32 02 05, Date of Issue:
June 2005
Superceded Bulletin(s): B32 200 05, Date of Issue:
March 2005
| BMW: | E65/E66 (7 Series) produced up to 3/05 |
| GROUP: | 32 - Steering and Wheel Alignment |
NOTE:
This Service Information bulletin supersedes Service Measure B32 200 05 dated March 2005.
SUBJECT
Chassis Integrated Module (CIM) Fault Code D98F "Timeout DME Message"
SITUATION
Servotronic failure warning is displayed in the Control Display and the steering effort may increase. The steering functions return to normal after restarting the engine.
CAUSE
Car Access System (CAS) data redundancy reading error.
CORRECTION
Depending on production date of the vehicle, CAS needs to be replaced (up to 2/03 production) or vehicle needs to be programmed (from 3/03 production).
PROCEDURE
- In case of a customer complaint, for vehicles produced up to 2/03 (equipped with CIM): Replace the CAS (Part Number: 61 31 6 942 487).
- In case of a customer complaint, for vehicles produced from 3/03 (equipped with CIM2): Program the vehicle with CIP 15.2 or higher.
PRODUCTION
Improved CAS is introduced in 3/05.