61 13 ... Circular Plugs, 4-, 7-, 10- 12-, 25-Pin, System D1.5/D2.5
Insert special tool with suitable connection side in connector and twist approx. 3° counter-clockwise.
The connector is locked down if detent lug (3) is located in locking groove (2).
- Unlocking groove
- Locking groove
- Detent lug
With special tool 61 1 132, press back arrester hook (4) of appropriate contact and pull out cable.