61 13... Installing fan connector for retrofitting/repairs
Special tools required:
The case can no longer be ordered.
Special tools:
- special tool 61 9 040
Choose contact sleeve (up to 4 mm2 ) in accordance with wire cross-section.
Alternatively:
Choose contact sleeves (up to 2.5 mm2 ) for fan connectors.
Cut through wire loop in wiring harness at established point.
Strip insulation from both wire ends.
Refer to repair instructions:
CUTTING TO LENGTH AND STRIPPING INSULATION FROM CABLES
Crimp contact sleeves on both wire ends.
Refer to repair instructions:
BUTT CONNECTOR FOR REPAIRING A PLUG CONNECTION .
Crimp connecting cable for retrofitting likewise with contact sleeve.
Cut required number of poles to length for fan connectors.
Special tool 61 9 041 (hand crimping tool) in conjunction with 61 9 042 (matrix) are used for pushing contact sleeves onto fan connectors.
Refer to repair instructions:
SPECIAL TOOLS FOR WIRING HARNESS REPAIRS .
Unlock special tool 61 9 041 :
Squeeze grips (1) lightly and push unlocking lever (2) in direction of arrow.
Or:
Compress handles as far as they will go, tool unlocks automatically.
Insert prepared fan connector (3) in special tool 61 9 041 / 61 9 042 .
Attach wire with contact sleeve to fan connector.
Press crimping tool together and slide contact sleeve firmly home.
Push on further contact sleeves for potential branching.
Installation in wet area (engine compartment, wheel arch):
Apply sealing compound on both sides and press into contacts (1).
Fit shrink-fit hose and heat up with hot air blower (2) (approx. 250 °C).
Do not heat shrink-fit hose on edges of fan connector too strongly, risk of cracking.
Allow shrink-fit hose to cool down until hand-warm. Then press sealing material again into contacts and onto edges of fan connector.
If necessary, carefully heat shrink-fit hose again.
Installation in dry area (interior, luggage compartment): Slide assembled fan connector into insulation housing until it locks into place.